Instructions / Assembly

SINGLE & DUAL SYSTEMS
STOP
INSTALLATION OF NATURAL GAS PILOT VALVE
This Safety Pilot Kit contains a C.S.A Certified Control Valve, which provides a safe and convenient way to
ignite and control the flame height on your energy efficient gas log set.
Note: Use pipe compound on all male threads to seal joints.
A. This Safety Pilot Kit contains a Natural Gas Orifice and L.P. Gas hardware. LP instructions are packaged
separately in this kit.
B. Attach Pilot Bracket (Part #8) to the Burner Pan using one sheet metal screw (Part #9). Install sheet metal
screw into top left hole of the bracket (See Figure 1)
C. Attach the 3/8" straight Flared Fitting
(Part #4) to the “IN” position of the
Gas Control Valve using pipe joint
compound (See figure 5).
D. Attach Pilot Gas Supply Line
(Part #6) and the Thermocouple Lead
(Part #5) to the Gas Control Valve
(See Figure 2)
NOTE: When connecting to the
Control Valve, hand tighten both
the Pilot Gas supply line and
Thermocouple lead, then tighten
1/8 turn with a wrench. DO NOT
OVER TIGHTEN as this may cause
the Pilot to not function properly.
Figure 2
Assembly
A
10
7
8
9
11
B
9
Figure 1 (A&B) Pilot Burner
PILOT ASSEMBLY
Gas Control Valve
Thermocouple Connection
Pilot Connection
Part 6
Part 5
Part 3
Pilot Burner Connections