Installation Guide

LOCAL CODES
Install and use log set with care. Follow all local
codes. In the absence of local codes, use the
latest edition of The National Fuel Gas Code ANSI-
Z223.1/NFPA 54*.
.
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
PRODUCT FEATURES
UNPACKING
CAUTION: Do not remove the metal data plates from the
burner pan. The data plates contain important warranty
and safety information.
1. Remove logs, hearth kit, pan materials,
and hardware from carton.
2.
Remove all protective packaging applied
to logs and base for shipment.
3.
Check appliance for any shipping damage.
If it is damaged call Sure Heat Manufacturing
at 1-800-229-5647 for replacement parts
before returning to dealer.
SAFETY VALVE/PILOT
This unit is provided with a gas control valve which
is connected to a standing pilot, allowing convenient
and safe operation.
Unit is tested and approved to ANSI Z21.60 as a vented
decorative appliance. It is supplied with the parts and ins-
tructions to convert to propane/LP gas use.
APPROVALS
4
WARNING: The Massachusetts State
Board requires all installations be perform-
ed by a Licensed Plumber or Gas Fitter. Mas-
sachusetts state code requires all vent
dampers be welded open or removed.
CAUTION: Do not remove the data plates
attached to the burner pan. The data plates
contain important warranty and safety infor-
WARNING: Before installing in a solid fuel
burning replace, the chimney flue and rebox
must be cleaned of soot, creosote, ashes and
loose paint by a qualified chimney cleaner.
Creosote will ignite if highly heated. A dirty chi-
mney flue may create and distribute soot within
the house. Inspect chimney flue for damage.
NOTICE: Installation, service, and repair of this appliance must
be performed by a qualified installer, service agency, comp-
any or gas supplier, experienced with this type of gas app-
liance. Only factory authorized components should be used,
in accordance with the manufacturer’s instructions and all
codes and requirements of the authority
having jurisdiction.
Any modifications to this appliance, or use of unauthorized
components or accessory items will void the manufacturer’s
warranty, and may result in a hazardous condition.
FLUE OPENING SPECIFICATIONS
Note: This vented appliance must be installed only in a
solid-fuel burning replace with a working flue and con-
structed of noncombustible material.
mation.
INSTALLATION
VENTING SPECIFICATIONS FOR
INSTALLATION
The fireplace chimney flue and vent must be draft-
ing properly. To check the vent for proper drafting:
Light a tightly rolled newspaper on one end and
place it at the inside front edge of the fireplace.
Observe the smoke and be sure the vent is pro-
perly drawing it up the chimney. If the smoke
spills out into the room, extinguish the ame and re-
move any obstruction until proper venting is
achieved.
The chimney flue damper must be fixed open to provide a
minimum of 81 sq. in. of free air opening during operation
of this log set. A multipurpose damper clamp is provided
to fix the damper in position.
The minimum flue sizes shown in Figure 2 are based on
a 6' chimney height using round pipe. Your minimum flue
size will vary based on input rate and chimney height. Refer
to the National Fuel Gas Code ANSI Z223.1/NFPA 54,
Section 6.6, for details.