Installation Guide

www.sureheat.com
200252-01A12
INSTALLATION
Figure 11 - Hood Installation
Remove 2
Screws from Top
Firebox Panel
Insulation
Board
Replace 2
Screws
Hood
Step 1
Step 2
Step 3
CAUTION: Do not operate
replace without hood in place.
1. Fireplace hood is positioned on top of
shipping inner pack.
2. Remove top of rebox by removing 2 screws
located on each end (see Figure 11).
3. Insert the hood along the upper side of
the heat insulation board (see Figure 11).
Attach hood with 3 screws.
4. Reattach rebox top by reinserting the 2
screws from step 2.
ASSEMBLING HOOD
Figure 9 - Rough Opening for Wall
Installation
23.25"
12.75"
28.75"
Figure 10 - Rough Opening for Corner
Installation
37.4"
28.75"
53.8"
26.5"
1. Frame in rough opening. Use dimensions
shown in Figure 9 for the rough opening.
If installing in a corner, use dimensions
shown in Figure 10 for the rough opening.
The height is 26
1
/
2
", which is the same as
the wall opening above.
2. Carefully set replace in front of rough
opening with back of replace inside wall
opening.
3. Attach gas line to replace gas regulator.
See Connecting to Gas Supply, page 13.
4. Check all gas connections for leaks. See
Checking Gas Connections, page 15.
IMPORTANT: When nishing your rebox,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc, must have 1/2" clearance to the sides
and top of the rebox. Combustible materials
should never overlap the rebox front.