Use and Care Manual

www.sureheat.com
200085-01A10
NG
Gas Inlet
Gas esté
INLET GAS PRESSURE
MAX 1/2 PSIG (3.5KPa)
Gas Select
Selector de gas
LP
NG
LP
NG
Gas Inlet
Gas esté
INLET GAS PRESSURE
MAX 1/2 PSIG (3.5KPa)
Gas Select
Selector de gas
LP
NG
LP
NG
Gas Inlet
Gas esté
INLET GAS PRESSURE
MAX 1/2 PSIG (3.5KPa)
Gas Select
Selector de gas
LP
NG
LP
NG
Gas Inlet
Gas esté
INLET GAS PRESSURE
MAX 1/2 PSIG (3.5KPa)
Gas Select
Selector de gas
LP
NG
LP
INSTALLATION
Figure 7 - Settings for Natural Gas
Selection
For changing from propane to
natural gas supply:
1. Remove 2 screws from gas selector cover
plate. Remove to expose fuel selector
device.
2. For NATURAL GAS, press in knob using
a at screwdriver with a blade with thick-
ness of a quarter and turn knob clockwise
until the knob locks into the NG po-
sition (see Figure 7). Fuel selection device
must be locked in the NG position. Do not
operate heater between locked positions!
3. Replace cover over fuel selection device
and reinstall screws.
4. Remove hex plug (with wrench provided)
from natural gas inlet of regulator and
discard (see Figure 7). Install gas line into
NG inlet of regulator. Use thread sealant
to assure there are no leaks.
Fuel
Selector
Knob
Fuel Selector
Knob
Hex Plug
Hex Plug
Figure 8 - Settings for Propane/LP Gas
Selection
Gas Connection
Fitting
Gas
Connection
Fitting
Back of Stove
Back of Stove
For changing from natural gas
supply to propane supply:
1. Remove 2 screws from gas selector cover
plate. Remove to expose fuel selector
device
2. For PROPANE GAS, press in knob using a
at screwdriver with a blade the thickness
of a quarter and turn knob counterclock-
wise until the knob locks into the
LP position (see Figure 8). Fuel selection
device must be locked in the LP position.
Do not operate heater between locked
positions.
3. Replace cover over fuel selection device
and reinstall screws.
4. Remove hex plug (with wrench provided)
from propane/LP gas inlet of regulator
(see Figure 8). Install hex plug into NG
inlet of regulator. Install gas line into LP
inlet of regulator. Use thread sealant to
assure there are no leaks.