Regulatory Compliance
5 Regulatory Compliance
5.1 Introduction
The purpose of this chapter is to describe which behavior the user MUST have in order to
operate the device under compliance with current regulations. The details described here
are then to be read carefully and applied literally. Also, please read carefully all the other
documentation available in order to understand all the limits and ensure compliance of
the final application.
The module EMB-LR1302-mPCIe will be certified for CE, FCC and IC compliance. The
different regulations have different limitations and impose different approaches to the
module that will be discussed in different chapters. Any aspect that both the regulations
have in common will be described in an appropriate chapter in order to keep readability
of this document at maximum.
The main aspect that the user MUST consider is the output power. The module itself is
compliant and ready to be used but care must be taken in setting an appropriate output
power when programming the devices. The module can output up to 27 dBm of conducted
power. Please follow the directives in this document to set the appropriate output power
for the antenna you are using. Any other antenna that is not covered in the certification
must not be used unless a new certification is performed.
5.2 Compliance: Important information
The module is to be used in accordance with the current guide. Any hardware
modification on the module will void the certification.
The antennas used must be one of those indicated by the manufacturer and the output
power must be set as required by the present document.
The EMB-LR1302-mPCIe can operate using the external antenna attached via the U.FL
connector. For the specific FCC certification, the list of allowed antennas are indicated in
the following table. The use of any other antenna is permitted only with a FCC Class two
permissive Change.
Antenna code Antenna type Antenna gain
EMB-ANT915-RD Rubber duck RP-SMA Antenna +2 dBi
User Manual EMB-LR1302-mPCIe Page 10 of 14
NB: in the standard use of the device a minimum distance of 20 cm between the radiant
element and the human body has to be maintained.