User's Manual

Electrical Characteristics
4 Electrical Characteristics
4.1 Absolute Minimum and Maximum Ratings
Parameter Min Max Unit
Power Supply
Voltage
-0.5 5.5 Vdc
Storage
Temperature
-40 125 °C
Table 2: Absolute minimum and maximum ratings.
4.2 Operating Conditions
Parameter Min Typ Max Unit
Power Supply Voltage (Vcc) USB 3.0 5 5.5 V
Operating Temperature range -40 25 +85 °C
Logic Low Input threshold -0.3 0.3*Vcc V
Logic High Input threshold 0.7*Vcc Vcc+0.3 V
Logic Low Output Level 0 0.4 V
Logic High Output Level Vcc-0.6 Vcc V
Table 3: Operating Conditions.
4.3 Power Consumption
Mode Typ. value Unit
Transmission @ +27dBm 421 mA
Transmission @ +20dBm 262 mA
Transmission @ +14dBm 148 mA
Reception 39 mA
Table 4: Power Consumption.
User Manual EMB-LR1302-mPCIe Page 8 of 14