If in doubt, it is reasonable and safer to disconnect the batteries from
the DPSI BIC. The bracket must then be unlocked, if used.
Hint:
Batteries with an additional charging cable (e.g. V-cable or charging connector)
must be charged one after another if connected to the DPSI BIC during recharge!
Simultaneously charging is not possible even with a charger with two outputs.
Hint:
Two identical batteries have to be used, i.e. same battery type (NiCd, NiMH,
LiIon, LiPo or LiFePO4 and same number of cells). The capacity may be
different, although it does not make sense.
Hint:
If the batteries are connected to the DPSI BIC during charging, a charger must
be used, whose output voltage (charge voltage) never exceeds 14V (=> limiting
step up converter). This is the case for all chargers (starting 2007). If the step up
converter is not limited, damage to the DPSI BIC is possible. If in doubt ask the
manufacturer of your charger!