9. Beginning of Operation
Initial operation, power on, operation display:
For power, two batteries of same type and capacity are necessary.
5-cell NiCd / NiMH or 2-cell Li++ batteries can be used (other cell
numbers for modified output voltage). Batteries must be equipped with
MPX high current sockets or identical connector system.
If the electrical connections are established, the DPSI BIC can be
turned on. After turning on and completed initialization (display:
“EMCOTEC BIC V2.0”) the used battery type is optically (LC-display)
and acoustically (piezo-buzzer) indicated. Thereby:
1 beep 5 cells NiCd / NiMH
2 beeps 6 cells NiCd / NiMH
3 beeps 2 cells LiIon
4 beeps 2 cells LiPo
5 beeps 2 cells LiFePO4
no beep buzzer deactivated