TURNING THE POWER ON
Turn the power to the spa on at the main circuit breaker. Verify that
your spa has no error codes. (See page 47) Verify that there is good
water circulation in the spa. The pumps will come on in cycles, for 1
minute each cycle.
VERIFYING WATER CIRCULATION
1) Open all the jets.
2) Press the Pump 1 key to turn the pumps on or off.
3) Make sure each seat has water ow. Note: On certain spas there is
a diverter valve. Verify where the diverter valve is located.
TESTING THE GFCI BREAKER
NOTE: The electrical service panel for your spa should be
equipped with a GFCI breaker. To avoid the risk of electrical
shock, perform the following safety test before each use of
your spa.
1) Make sure the power is turned on at the electrical service panel.
2) Turn on the GFCI breaker. If the breaker stays on, it is functioning
properly.
DANGER: RISK OF ELECTRICAL SHOCK
If the GFCI breaker fails to operate as described, there is a possibility
of an electric shock if the spa is used. Shut off the power at the main
electrical service panel until the source of the problem has been
identied and corrected by a licensed electrician or qualied spa
technician.
19
7) With the front panel off, verify there are no leaks at the
pump union.
Note: Pump unions can become loose during shipping.
Verify that there are no leaks during lling of the spa.
8) Reinstall the circulation pump screen and all lters.
FILLING THE SPA WITH WATER cont...