1. Install a 50-amp, GFCI overcurrent protective device in the
electrical service panel.
2. The electrical supply for the spa must include a suitable rated
switch or circuit breaker to shut off the power supply (to
comply with section 422-20 of the National Electrical Code,
ANSI/NFPA 70-1996). This disconnecting means must be
readily accessible to the spa occupant, but must not be within
5 feet of the spa.
3. With the spa placed in its final location, power can be routed in
two ways:
Under the spa cabinet- See figure 1 on pg. 11
- Determine placement of hole in floor so that conduit may enter
between the spa shell and the wooden cabinet.
- Move the spa to allow working room. Cut off the conduit above
the floor surface.
- Use an LB on the conduit to permit wire pulling if required.
Through a power entrance opening drilled by an
electrician - See figure 2 on pg. 11
- Move the spa to allow working room. Use nonmetallic conduit
and fittings. Cut off the conduit above the floor surface to
permit the installation of an LB at the power entrance opening
height.
240V Systems
(Lite Leader 240V,
SS-1D, SS-3D,
DS-2, DS-4)