Owner`s manual

Spa Side Control
Panel SS-3D
(Continued)
Preset Filter Cycles
Your spa will automatically filter itself twice each day. The first filter
cycle will begin one minute after the spa is energized. The second filter
cycle will begin twelve hours later. To clean out the blower lines, the air
jets will run for 30 seconds at the start of the first filter cycle. During
filtration, the low-speed pump will activate. The ozone generator (if
installed) will run 24 hours per day, but is assisting with water purification
only when the pump is running. Filter duration is programmable via the
topside panel.
Setting the Filter Cycles
Press the "Set" pad, then the "Jets" pad, and "F3" will be displayed on the
panel. "F3" is the default filter time and indicates a 3 hour cycle. Press the
"Set" pad again to cycle through the rest of the filter time options; "F6" = 6
hours, "F9" = 9 hours, and "FC" = 12 hours. After you have selected your
duration, press the "Jets" pad again to exit the programming mode.
Safety Features
Overheat Protection (Spa is deactivated)
If your spa should overheat, the display will flash {OH}. In such a
condition, DO NOT ENTER THE WATER. Turn off all power to the spa
and contact your dealer or service organization. Overheating may also
occur if the filter duration is set too long at the time of installation. To reset
the spa, press any panel button.
Flow Switch Detection
If a pressure switch malfunctions, the display will show {FL}. Contact your
dealer or service organization.
Open Sensor (Spa is deactivated)
If the high-limit sensor or water temperature sensor malfunctions, the
display will show {Sn}. Contact your dealer or service organization.
23
Features and Controls