Owner`s manual

Spa Side Control
Panel DS-2
(continued)
Standard or Economy Mode
Press this pad to switch between modes. Economy mode
only heats the water during filter cycles. Standard mode
maintains the desired set temperature at all times.
Filter Cycles
Your spa will automatically filter itself twice a day. The first filter cycle
will start one minute after the spa is powered up. The second filter cycle
will begin twelve hours later. The blower will run for 30 seconds at the
start of the first cycle to clean out the air lines. The low-speed pump will
run during filter cycles (unless the high-speed pump is activated) and the
heater will be on. The ozone generator (if installed) will run 24 hours per
day, but is assisting with water purification only when the pump is run-
ning. Filter cycle duration is programmed via the topside panel for 3, 6, 9
or 12 hours. To program, press the "Warm" or "Cool" pad, then press the
"Mode" pad. Press the "Warm" or "Cool" pad again to select the duration of
the twice-daily cycle. Press the "Mode" pad to program the heater to enable
or disable during filter cycles.
Cleanup Cycle
The low-speed pump turns on 20 minutes after the jets pad is pressed. The
cleanup cycle runs for 2 hours.
Disabling Pumps
In times when you are entertaining or relaxing in the area of your spa, you
can turn off the pump to avoid hearing any spa operational noise due to
filtering or ozonating. To do this press the "Warm" or "Cool" pad, then the
"Light" pad, and all spa functions will be disabled except for freeze control.
To resume spa operation, press any panel button.
Center Display Messages
These are some of the messages you may see on the center display.
Standard
The spa is in standard mode. StAN is flashed alternately
with the current spa temperature and COOL until the spa
water is 20
o
F cooler than the set temperature.
Economy
The spa is in economy mode. ECON is flashed alternately
with the current spa temperature and COOL until the spa
water is 20
o
F cooler than the set temperature.
Overheat protection
If a malfunction occurs and spa water reaches 112
o
F, or
the high-limit sensor has detected 118
o
F at the heater the
spa is deactivated. In such a condition, DO NOT ENTER WATER!
Remove the spa cover and allow the water to cool. At 110
o
F the spa should
automatically reset. If the spa does not reset, shut off power to the spa and
call your dealer or service organization.
25
Features and Controls