Owner`s manual
27
Features and Controls
General Description
Your Control panel consists of three main parts:
1.
User's Keypads
Temperature Controls (60
o
F - 104
o
F)
When either of these pads is touched once,
the LCD will display the temperature which
has been set, as well as the words "SET HEAT".
Each time either of these pads is pressed again,
the set temperature will increase or decrease, depending on which pad is
pressed. After 3 seconds, the LCD will automatically display the spa
temperature.
Jets Keypad
Touch this pad once to activate the low-speed pump. Touch
again to activate the high-speed. Press the pad a third time
and the second pump will also activate. Press the pad again
to deactivate the pump(s). The low-speed pump starts automatically when
the heater is turned on, when a filter cycle is activated, or when a freezing
condition is detected. If automatically activated, the low-speed pump
cannot be turned off with the "jets" pad; however, the high-speed pump
may be started. When the low-speed pump is started with this pad, it will
automatically stop after 2 hours and 20 minutes of operation. The high-
speed pump will stop after 15 minutes.
Blower Keypad
Touch the blower keypad to activate the first speed of the
blower (high). Press the pad again to activate the second
speed of the blower (low) and once again to turn the blower
off. The blower will automatically turn off after 15 minutes.
Spa Side Control
Panel DS-4
Start-up
When your spa is powered up, it begins running in standard mode,
which automatically heats and maintains the water at 100
o
F. Pressing
the # pad switches the spa from standard mode to economy mode. This
setting is designed for periods of little or no use, but continues to filter
twice a day and maintains water quality