Owner`s manual
38
Emerald Whirlpool Spa Owner's Manual
Two-Pump Priming
[for spas equipped
with DS-2 and DS-4]
Note:
If water does not flow within a
minute or two, turn off all power
to the spa and repeat steps for
bleeding air.
Caution:
Never run the system without circulating water! Doing so can damage
pumps and void the warranty.
Each pump must be primed separately. To accomplish this, follow these
steps.
1. Press the "Jets" key pad twice. The circulating/jets pump will
operate in the low speed mode on the first press and in the high
speed mode on the second press. The high speed mode will
facilitate pump priming.
2. When the jets begin to operate moderately, the circulating/jets
pump is completely primed.
3. Now press the "Jets" key pad a third time. The jets booster pump
will now operate.
4. When the jets begin to operate more vigorously, the jets booster
pump is completely primed. If you do not see any distinguishing
difference in jet flow when pressing the "Jets" button a third time
then the booster pump may require direct priming.
A. Remove the equipment panel and locate the booster pump
(see 2-pump system diagram on page 16).
B. With the booster pump running turn the pump drain plug
counterclockwise until a steady stream of water appears.
Once water appears quickly tighten the plug and you
should notice a more intence flow of water through the jets.
C. If no noticeable difference has occured repeat step B.
Water Line Connection goes to the jet