2.0 IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
WHEN INSTALLING AND USING THIS ELECTRICAL EQUIPMENT,
BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING:
1. WARNING: To reduce the risk of injury, do not permit children to use
this product unless they are closely supervised at all times.
2. WARNING: A grounding wire connector is provided on this unit to
connect a minimum No. 8 AWG (8.4 mm²) solid copper conductor
between this unit and any metal equipment, metal enclosures of
electrical equipment, metal water pipe, or conduit within 5 feet (1.5m)
of the unit.
3. DANGER: Risk of Accidental Drowning. Extreme caution must be
exercised to prevent unauthorized access by children. To avoid
accidents, ensure that children cannot use this spa unless they are
supervised at all times.
4. DANGER: Risk of Injury. The suction ttings in this spa are sized to
match the specic water ow created by the pump. Should the need
arise to replace the suction ttings or the pump, be sure that the ow
rates are compatible. Never operate the spa if the suction ttings are
broken or missing. Never replace a suction tting with one rated less
than the ow rate marked on the original suction tting.
5. WARNING: Risk of Injury. The suction ttings in this spa are sized to
match the specic water ow created by the pump. If it is necessary
to replace the suction ttings or the pump, be sure that the ow rates
are compatible. Because of the risk of injury:
Never operate or use the spa if the lter, lter lid, or skimmer
assembly are broken or any part of the skimmer assembly is
missing. Please contact your dealer or nearest service center for
service.
Never replace a suction tting with one rated less than the ow
rate marked on the original suction tting.
6. DANGER: Risk of Electric Shock. Install at least 5 feet (1.5m),
from all metal surfaces. As an alternative, a spa may be installed
within 5 feet of metal surfaces if each metal surface is permanently
connected (bonded) by a minimum No. 8 AWG (8.4 mm²) solid
copper conductor attached to the wire connector on the grounding
lug, inside the equipment compartment on the equipment box.