Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Alphaline® Nuclear Pressure Transmitter www.rosemountnuclear.
No. 1 2 3 IMPORTANT NOTICE -- ERRATA Model 1153 Series D Product Manual 00809-0100-4388 Rev BA (January 2008) Affected Description of Change Pages Process Flange –CF3M (Cast version of 316L SST) 6-8 Drain/Vent Valves –316L SST Process Connections – 3/8-inch Swagelok compression fitting, 316L SST (1/4-18 NPT optional) 3-8 Change the first paragraph on the page to read as follows: ”Damping electronics are available as an option.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Rosemount 1153 Series D Alphaline® Pressure Transmitters NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing, using, or maintaining this product. For equipment service needs outside the United States, contact the nearest Rosemount representative.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Rosemount Nuclear Instruments, Inc. Warranty and Limitations of Remedy The warranty and limitations of remedy applicable to this Rosemount equipment are as stated on the reverse of the current Rosemount quotation and customer acknowledgment forms. RETURN OF MATERIAL Authorization for return is required from Rosemount Nuclear Instruments, Inc. prior to shipment. Contact Rosemount Nuclear Instruments, Inc.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Revision Status Changes From 1999 to January 2008 Page (Old) Page (New) Changes Cover Inside cover, i, ii, 5-9 & back cover 3-7, 6-9 & 6-10 Cover ii & back cover Document revision date change from May 1999 to January 2008, rev from AA to BA Include errata sheet information on address and phone numbers 3-8, 6-11 & 6-12 Include errata sheet information on circuit board number changes: • Replaced amplifier circuit card, outp
Reference Manual Rosemount 1153 Series D iv 00809-0100-4388, Rev BA January 2008
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Table of Contents SECTION 1 Introduction Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 About The Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 SECTION 2 Installation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 General Considerations . . . . . . . . . . . . . . . . .
Reference Manual Rosemount 1153 Series D 00809-0100-4388, Rev BA January 2008 SECTION 5 Maintenance and Troubleshooting Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 Test Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Board Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-4388, Rev BA January 2008 Section 1 Rosemount 1153 Series D Introduction Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-1 About The Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-1 OVERVIEW This manual is designed to assist in installing, operating, and maintaining the Rosemount 1153 Series D Pressure Transmitter.
Reference Manual Rosemount 1153 Series D 1-2 00809-0100-4388, Rev BA January 2008
Reference Manual 00809-0100-4388, Rev BA January 2008 Section 2 Rosemount 1153 Series D Installation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1 General Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1 Mechanical Considerations . . . . . . . . . . . . . . . . . . . . . . . . page 2-2 Electrical Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-4 Installation Procedures . . . . . . . . . . . . . . . .
Reference Manual Rosemount 1153 Series D MECHANICAL CONSIDERATIONS 00809-0100-4388, Rev BA January 2008 This section contains information you should consider when preparing to mount the transmitter. Read this section carefully before proceeding to the mechanical installation procedure. Mount the Rosemount 1153 Series D transmitter to a rigid support (a support with a fundamental mechanical resonant frequency of 40 Hz or greater).
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Proper location of the transmitter with respect to the process tubing depends on various process parameters. When determining the best location, consider the following: • Keep hot or corrosive fluids from contacting the transmitter. • Prevent sediment from depositing in the impulse tubing. • Ambient temperature gradients and fluctuations can result in erroneous transmitter readings.
Reference Manual Rosemount 1153 Series D 00809-0100-4388, Rev BA January 2008 For differential transmitters, also consider the following: • Keep both impulse legs at the same temperature. • When using sealing fluid, fill both piping legs to the same level. • When purging, make the purge connection close to the process taps and purge through equal lengths of the same size tubing. Avoid purging through the transmitter. Conduit The conduit connection to the transmitter is 1/2–14 NPT.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Figure 2-2. Transmitter Wiring Connections. Power Supply Terminal Side (Cover Removed) Figure 2-3. Transmitter Load Limits. Output Code P 4—20 mA DC 2000 1650 Qualified Region 1500 Load Resistance (Ω) 1325 1000 Design Region 500 0 0 45 40 30 12 13.5 Power Supply (V DC) Output Code R 4—20 mA DC 1825 Load Resistance (Ω) 1575 Qualified Region 1500 1000 Design Region 500 0 0 50 40 12 13.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D INSTALLATION PROCEDURES Installation consists of mounting the transmitter and conduit and making electrical connections. Following are procedures for each operation. Mechanical Transmitter Be careful not to break the neck seal between the sensor module and the electronics housing. The threaded interface between the sensor module and the electronics housing is hermetically sealed before shipment.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Figure 2-5. Transmitter Dimensional Drawings. ROSEMOUNT 1153DD AND 1153HD 4.7 Max. (119.4) 0.75 (19) Clearance for Cover Removal (Typical) 4.72 Max. (119.9) 1 /2–14 NPT Conduit Connection (1 place) 9 Max. (228.6) Nameplate (Remove for Zero and Span Adjust) Transmitter Circuitry (this Side) 7 /16–20 UNF (Typical) Terminal Connections (this Side) 3.7 (94) 1.63 (41.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Conduit 1. Seal the conduit threads with thread sealant (the transmitter conduit seal interface was qualified using Grafoil™ tape). Conduit threads mate with a standard 1/2–14 NPT male fitting. 2. Starting at zero thread engagement, install the conduit into the transmitter between 4 and 7 turns, or a minimum of 12.5 ft-lb (16.9 N-m).
Reference Manual 00809-0100-4388, Rev BA January 2008 Electrical Rosemount 1153 Series D 1. Remove the cover from the terminal side of the transmitter (see Figure 2-5 on page 2-7). 2. Connect the power leads to the “SIGNAL” terminals on the transmitter terminal block (see Figure 2-7 on page 2-9). Torque the terminal screws to 5 in-lb (0.6 N-m), or hand-tight. Do not connect signal leads to the “TEST” terminals. 3. Recheck the connections for proper polarity. 4.
Reference Manual Rosemount 1153 Series D 2-10 00809-0100-4388, Rev BA January 2008
Reference Manual 00809-0100-4388, Rev BA January 2008 Section 3 Rosemount 1153 Series D Calibration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1 Calibration Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-3 OVERVIEW Each transmitter is factory calibrated to the range specified by the customer.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Figure 3-1. Zero Adjustment Range. 20 Output (mA) 600% Zero Elevation 4 -150 -100 -75 -50 -125 -25 0 25 Pressure (inH2O) 600% Zero Elevation➀ 20 Output (mA) 4 0 25 Pressure (inH2O) No Zero Elevation or Suppression➀ 20 Output (mA) 4 0 25 50 75 100 125 150 Pressure (inH2O) 500% Zero Suppression➀ ➀Graphs based on a Range 4 (0-25 to 0-150 inH2O) Rosemount 1153 Series D with a calibrated span of 25 inH2O.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D CALIBRATION PROCEDURES Zero and Span Adjustment NOTE The Rosemount 1153 Series D Pressure Transmitter contains electronic circuit boards which may be static sensitive. NOTE Covers need not be removed for zero and span adjustment. The zero and span adjustment screws are accessible externally. They are located behind the nameplate on the side of the electronics housing (see Figure 3-2 on page 3-3).
Reference Manual Rosemount 1153 Series D 00809-0100-4388, Rev BA January 2008 1. Adjust the zero to eliminate any existing zero elevation or suppression. With 0 inH2O pressure applied to the transmitter, turn the zero adjustment until the output reads 4 mA. The unit is now calibrated for 0 to 100 inH2O. 2. Adjust the span to the desired new span.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D B1. Method (Output Code P—Amplifier Board with Holes) a. Cut the jumper wire, form, and insert across 2 jumper pads on the component side of the board in the “elevate zero” position (see Figure 3-3 (Detail A2) on Page 3-7). b. Turn the board over and clip the wire ends to the appropriate length. In accordance with proper electronic practices, solder the jumper wire to the board. Clean solder joints with isopropyl alcohol. c.
Reference Manual Rosemount 1153 Series D 00809-0100-4388, Rev BA January 2008 1. Apply mid-range pressure and note the error between theoretical and actual output signal. 2. Apply full-scale pressure. Multiply the error noted in step 1 by six and by the rangedown factor. Maximum Allowable Span Rangedown Factor = --------------------------------------------------------------------Calibrated Span 3.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Figure 3-3. Jumper Wire Placement.
Reference Manual Rosemount 1153 Series D 00809-0100-4388, Rev BA January 2008 Figure 3-4. Linearity and Damping Adjustment. Damping Adjustment (Optional on “R” Electronics Only) Electronics Side of Transmitter Housing (Cover Removed) Damping Adjustment Linearity Adjustment Damping electronics are available as an option.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Correction For High Line Pressure (Rosemount 1153DD and 1153HD Only) Span If a differential transmitter is calibrated with the low side at ambient pressure but will be used at high line pressure, correct the span adjustment to compensate for the effect of static pressure on the unit. If zero is elevated or suppressed, also correct the zero adjustment.
Reference Manual Rosemount 1153 Series D 7. 00809-0100-4388, Rev BA January 2008 Calculate full-scale adjustment correction in terms of pressure: 0.9 % × 300 inH 2 O = 2.7 inH 2 O 8. Repeat step 4 with the results of step 7: 2.7 inH 2 O ---------------------------------------------------------- = 0.675 % span 400 inH 2 O input span 9. Repeat step 5 with the result of step 8: 0.675 % × 16 mA span = 0.108 mA 10. Add the mA correction to the ideal full-scale output (20 mA).
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D 1. Using standard calibration procedures, calibrate the unit to the required span, with the 4 mA or zero point corresponding to zero differential pressure: 4 mA at 0 inH2O and 20 mA at 400 inH2O 2. Apply static pressure to both high and low process connections with zero differential pressure across the transmitter, and note the zero correction (zero shift). For example, if the output reads 4.
Reference Manual Rosemount 1153 Series D 3-12 00809-0100-4388, Rev BA January 2008
Reference Manual 00809-0100-4388, Rev BA January 2008 Section 4 Rosemount 1153 Series D Operation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-1 Transmitter Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-1 The ␦-Cell Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-3 Demodulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-3 Linearity Adjustment . . . . . . . . . . . .
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D K1 is a constant. C1 is the capacitance between the high pressure side and the sensing diaphragm. C2 is the capacitance between the low pressure side and the sensing diaphragm. Where: I ref fV p – p = ---------------------C1 + C2 Iref is the current source. Vp-p is the peak-to-peak oscillation voltage. f is the oscillation frequency.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Figure 4-2. The ␦-Cell.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D OSCILLATOR The oscillator has a frequency determined by the capacitance of the sensing element and the inductance of the transformer windings. The sensing element capacitance is variable. Therefore, the frequency is variable about a nominal value of 32 kHz.
Reference Manual 00809-0100-4388, Rev BA January 2008 Section 5 Rosemount 1153 Series D Maintenance and Troubleshooting Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-1 Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-1 Test Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-2 Board Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Process o-rings may retain some process fluid after disassembly of process flanges. If this fluid is determined to be contaminated, take appropriate safety measures. TEST TERMINALS The test terminals are connected across a diode through which the loop signal current passes. The indicating meter or test equipment shunts the diode when connected to the test terminals.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D 1. Disengage the header assembly board (4) as described in the electrical housing disassembly procedure on 5-4. You need not remove the sensing module from the electrical housing for checkout. 2. Jump connections 1 and 2 on the header assembly board (see Figure 5-1 on page 5-2). 3. Using a low-voltage ohmmeter, check the resistance between the jumper wire and sensing module housing.
Reference Manual Rosemount 1153 Series D Electrical Housing Disassembly Removing Sensor Module from Electrical Housing REASSEMBLY PROCEDURE 00809-0100-4388, Rev BA January 2008 1. The signal terminals and test terminals are accessible by unscrewing the cover (1) on the terminal side. This compartment is identified as “terminal side” on the nameplate. The terminals are permanently attached to the housing and must not be removed. 2.
Reference Manual 00809-0100-4388, Rev BA January 2008 Preliminary Connecting Electrical Housing to Sensor Module Electrical Housing Reassembly Rosemount 1153 Series D 1. Replace the cover O-rings (2) whenever you remove a cover. Clean the sealing areas with alcohol, if necessary, and lightly grease the O-ring with Dow Corning 55 Silicone O-ring Grease (Rosemount P/N 01153-0248-0001 or P/N 01153-0053-0001).
Reference Manual Rosemount 1153 Series D Process Flange Reassembly 00809-0100-4388, Rev BA January 2008 1. Replace the metal O-rings (11) with new O-rings if the flanges were removed. 2. Carefully place an O-ring (11) in the isolator well of the high side (“H”) of the sensing module. Place the O-ring so the edge of the rolled ring faces the module. (See Detail A of Figure 5-2 on page 5-7). 3. Carefully place the flange (13 or 15) as shown in Figure 5-2 on page 5-7.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Figure 5-2. Typical Rosemount 1153 Series D Exploded View. 20 17 1 2 16 3 18 5 4 19 6 7 2 C 1 10 A B 9 D 10 8 13 Flange C 11 A 12 12 11 11 O-ring B D 15 DETAIL A 1154-1154A02D 15 Module 14 Table 5-1. Rosemount 1153 Series D Parts List.
Reference Manual Rosemount 1153 Series D 00809-0100-4388, Rev BA January 2008 Table 5-2. Torque References. Item To Be Torqued Torque Value Tolerance Bracket to Mounting Panel Bolts 19 ft-lb (26 N-m) ±1 ft-lb (1 N-m) Transmitter to Bracket Bolts 21 ft-lb (29 N-m) ±1 ft-lb (1 N-m) Swagelok Process Fittings See installation instructions Drain/Vent Valves 7.5 ft-lb (10 N-m) ±0.5 ft-lb (0.7 N-m) Covers 16.5 ft-lb (22.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Table 5-3. Troubleshooting. Symptom High Output Potential Source Primary Element Impulse Piping Transmitter Electronics Transmitter Electronics Failure Sensing Module Low Output or No Output Power Supply Primary Element Corrective Action Check for restrictions at primary element, improper installation or poor condition. Note any changes in process fluid properties. Check for leaks or blockage.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Symptom Erratic Output Potential Source Corrective Action Loop Wiring Do not use over 100 volts to check the loop, or damage to the transmitter electronics may result. Impulse Piping and Process Connections Transmitter Electronics Transmitter Electronics Failure Power Supply 5-10 Check for adequate voltage to the transmitter. Check for intermittent shorts, open circuits and multiple grounds.
Reference Manual 00809-0100-4388, Rev BA January 2008 Section 6 Rosemount 1153 Series D Specifications and Reference Data Nuclear Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6-1 Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . page 6-3 Functional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . page 6-6 Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6-8 Important Notice . . . . . . . . . . . . . .
Reference Manual Rosemount 1153 Series D 00809-0100-4388, Rev BA January 2008 Steam Pressure/Temperature: Accuracy within ±(4.5% upper range limit + 3.5% span) during and after exposure to steam at the following temperatures and pressures: 420 °F (215.6 °C), 95 psig for 3 minutes 350 °F (176.6 °C), 120 psig for 7 minutes 320 °F (160 °C), 70 psig for 8 hours 265 °F (129.4 °C), 24 psig for 67 hours Range Code 0: ±(6.7% of upper range limit + 3.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Figure 6-1. Qualified Life vs. Ambient Temperature. Module Qualified Life Time (Years) Electronics Qualified Life Temperature (°F) PERFORMANCE SPECIFICATIONS Based on zero-based ranges under reference conditions. Accuracy ±0.25% of calibrated span; includes combined effects of linearity, hysteresis, and repeatability Dead Band None Drift ±0.2% of upper range limit for 30 months (±0.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Rosemount 1153HD: Maximum zero shift after 3,000 psi (20.68 MPa) overpressure: Range Code Overpressure Effect 4 ±1.0% of upper range limit 5 ±2.0% of upper range limit 6, 7 ±5.0% of upper range limit Rosemount 1153GD and 1153AD: Maximum zero shift after 2,000 psi (13.8 MPa) overpressure: Range Code Overpressure Effect 3, 4 ±0.25% of upper range limit 5–8 ±1.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Load Effect No load effect other than the change in the voltage supply to the transmitter Mounting Position Effect No span effect; zero shift of up to 1.5 inH2O (372 Pa) which can be calibrated out Response Time Fixed time constant (63%) at 100 °F (37.8 °C) as follows: Range Code Response Time 3 2 seconds or less 4 0.5 seconds or less 5–9, 0 0.2 seconds or less Adjustable damping is available through a special N-Option.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D FUNCTIONAL SPECIFICATIONS Service Liquid, gas, or vapor Output 4–20 mA dc Power Supply Load limits are as shown in Figure 6-2 Figure 6-2. Load Limits. Transmitter Load Limits Output Code P 4—20 mA DC 2000 1650 Qualified Region 1500 Load Resistance (Ω) 1325 1000 Design Region 500 0 0 45 40 30 12 13.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Temperature Limits Normal operating limits: 40 to 200 °F (4.4 to 93.3 °C) Qualified storage limits: –40 to 120 °F (–40 to 48.9 °C) Humidity Limits 0–100% relative humidity (NEMA 4X) Volumetric Displacement Less than 0.01 in3 (0.16 cm3) Turn-On Time 2 seconds maximum. No warm-up required. Pressure Ranges Rosemount 1153DD and 1153HD: Range Code Pressure Ranges 3 0–5 to 0–30 inH2O (D units only) (0–1.24 to 0–7.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Static Pressure and Overpressure Limits Rosemount 1153DD: 0.5 psia to 2,000 psig (3.4 kPa abs to 13.8 MPa) maximum rated static pressure for operation within specifications; overpressure limit is 2,000 psig (13.8 MPa) on either side without damage to the transmitter Rosemount 1153HD: 0.5 psia to 3,000 psig (3.4 kPa abs to 20.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Process Connections 3 /8-in. Swagelok compression fitting, 316 SST (1/4–18 NPT optional) Electrical Connections 1 /2 –14 NPT conduit with screw terminals Weight 24 lb (10.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Table 6-1. Transmitter Design Specifications. Model Product Description 1153 Alphaline Pressure Transmitters for Nuclear Applications Code Pressure Measurement D H A G Code D Differential Pressure; 2,000 psig (13.8 MPa) Static Pressure Rating Differential Pressure; 3,000 psig (20.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Table 6-2. Rosemount 1153 Series D Spare Parts List. Spare Parts Category(1) Traceable Part Quantity Required Item Number (see Figure 5-2 on page 5-7) Part Description Rosemount 1153DD Order No. Rosemount 1153HD Order No. Rosemount 1153GD Order No. Rosemount 1153AD Order No. Amplifier Cir. Board, Output Code P Calib. Cir.
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Spare Parts Category(1) Traceable Part Quantity Required Item Number (see Figure 5-2 on page 5-7) Rosemount 1153DD Order No. Rosemount 1153HD Order No. Rosemount 1153GD Order No. Rosemount 1153AD Order No.
Reference Manual 00809-0100-4388, Rev BA January 2008 IMPORTANT NOTICE Rosemount 1153 Series D There are factors to consider concerning maintenance of qualification and traceability during on-site instrument repair because of the nuclear use intended for these parts. Rosemount Nuclear Instruments, Inc. rigidly controlled the original assembly of the instrument to ensure that the specifications were met.
Reference Manual Rosemount 1153 Series D 6-14 00809-0100-4388, Rev BA January 2008
Reference Manual 00809-0100-4388, Rev BA January 2008 Rosemount 1153 Series D Index A J S About The Transmitter . . . . . . 1-1 Jumper Wire Placement . . . . . 3-7 B L Safety Messages . . . . . . . . . .5-1 Sensing Module Checkout . . . .5-2 Span . . . . . . . . . . . . . . . . . . .3-9 Span Adjustment . . . . . . . . . .3-1 Span and Zero . . . . . . . . . . . .6-6 Spare Parts Shelf Life . . . . . .6-12 Static Pressure and Overpressure Limits . . . . . . . . . . . . . . . . . .
Reference Manual Rosemount 1153 Series D Index-2 00809-0100-4388, Rev BA January 2008
Reference Manual 00809-0100-4388, Rev BA January 2008 The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount, the Rosemount logotype, and Alphaline are registered trademarks of Rosemount Inc. ␦-cell is a trademark of Rosemount, Inc. All other marks are the property of their respective owners. Emerson Process Management Rosemount Nuclear Instruments, Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) (952) 949-5210 F (952) 949-5201 www.rosemountnuclear.