Use and Care Manual

11
Heating/Humidifier
1. Press SYSTEM key to select HEAT. If the auxiliary heating
system has a standing pilot, be sure to light it.
2. Press to adjust thermostat setting to 1°
above the
room temperature. The heat pump system should begin
to operate. The display should show "System On".
However, if the system configuration is set to HP1 or
HP2 and setpoint temperature display is flashing, the
5 minute compressor lockout feature is operating (see
Configuration menu, item 11).
3. Adjust temperature setting to 3° above room temperature.
If your system configuration is set at MS2, HP1 or HP2,
the auxiliary heat system should begin to operate and the
display will show "System On +2".
4. Press to adjust the thermostat below room
temperature. The heating system should stop operating.
To check the humidifier when System On appears and the
heating system is running press the HUMIDITY* button once.
Press to adjust the humidity 2% or more above the room
humidity level setpoint range. (Humidity setpoint can be
adjusted from 5 to 50%.) Hum On will appear indicating it is
calling for the humidifier.
*Note: If Auto Schedule is displayed instead of Humidity,
Auto Schedule must be turned off in the Configuration Menu.
Emergency Mode
Applies only to Heat Pump Systems
Emergency Heat (System EM Position) bypasses the Heat
Pump to use the heat source wired to terminal W/E, W2
on the thermostat. EM is typically used when compressor
operation is not desired, or you prefer back-up heat only.
1. Press SYSTEM key to select EM. “EM Heat Mode” will
flash on the display.
2. Press to adjust thermostat setting above room
temperature. The Emergency heating system will begin to
operate. The display will show “System On” flashing “EM
Heat Mode” and “Heat” to indicate that the Emergency
system is operating.
3. Adjust temperature setting to 3° above room temperature.
Any additional stages of auxiliary heat should begin to
operate and the display will show "System On +2".
4. Press to adjust the thermostat below room
temperature. The heating system should stop operating.
Cooling/Dehumidifier
1. Press SYSTEM to select "Cool".
2. Press to adjust the thermostat setting below room
Do not allow the compressor to run unless the compres-
sor oil heaters have been operational for 6 hours and the
system has not been operational for at least 5 minutes.
CAUTION
!
To prevent compressor and/or property damage, if the
outdoor temperature is below 50°F, DO NOT operate
the cooling system.
CAUTION
!
temperature. The blower should come on immediately on
high speed, followed by cold air circulation. The display
should show "System On". If the setpoint temperature
display is flashing, the compressor lockout feature is
operating (see Configuration menu, item 11).
3. Adjust temperature setting to 3° below room temperature.
The second stage cooling should begin to operate and the
display should show "System On +2".
4. Press to adjust the temperature setting above room
temperature. The cooling system should stop operating.
To check the dehumidifier when System On appears and
the cooling system is running press HUMIDITY* button
once. Press to adjust the humidity 2% or more below the
room humidity level setpoint range. DeHum On will appear
indicating it is calling for the dehumidification.
If the room humidity is lower than the adjustment range,
press to 40% and hold it for four seconds. This will force
the DeHum On for one complete cooling cycle to test the
dehumidification equipment.
After adjusting the humidity setting the display will return
to temperature in approximately 10 seconds. To switch the
display back to temperature immediately after adjusting
humidity setting press HUMIDITY again.
*Note: If Auto Schedule is displayed instead of Humidity,
Auto Schedule must be turned off in the Configuration Menu.
Choose the Fan Setting (Auto or On or Prog)
There are two fan features on the 1F95-1291:
1. Fan Auto/On Traditional Fan Settings
Press Fan to select Auto or On. The most commonly
used setting is Auto. Fan Auto runs the fan only when the
heating or cooling system is operating. Selecting Fan On
runs the fan continuously for increased air circulation or to
allow additional air cleaning if the system is equipped with
an Electronic Air Cleaner.
2. FAN Prog – Comfort Circulating Fan Feature
Pressing FAN until FAN Prog appears activates
the Comfort Circulating Fan Option. This causes the
thermostat to cycle the fan on for 10 minutes and off for
20 minutes if the thermostat has not called for heat or cool
during the past 60 minutes. This assures moderate air
circulation even when the heating and cooling equipment
is not cycling.
Choose the System Setting
(Cool, Off, Heat, Em, Auto)
Press the SYSTEM key to select:
Cool: Thermostat controls only the cooling system.
Off: Heating and Cooling systems are off.
Heat: Thermostat controls only the heating system.
Em: Setting is available only when the thermostat is
configured in HP1 or HP2 mode.
Auto: Auto Changeover is used in areas where both heating
and cooling may be required on the same day. AUTO allows
the thermostat to automatically select heating or cooling
depending on the indoor temperature and the selected heat
and cool temperatures. When using AUTO, be sure to set the
Cooling temperatures more than 1° Fahrenheit higher than
the heating temperature.
OPERATING YOUR THERMOSTAT