Use and Care Manual
14
PROGRAMMING 
Cooling
Program
Wake Up
(Morning)
Fan
Leave For Work
(Day)
Fan
 Return Home
(Evening)
Fan
Go To Bed 
 (Night)
Fan
MON
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto
TUE
WED
THU
FRI
SAT
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto
SUN
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto
Worksheet for Re-Programming 5+1+1 and 7 Day Program
Heating
Program
Wake Up
(Morning)
Fan
Leave For Work
(Day)
Fan
 Return Home
(Evening)
Fan
Go To Bed 
 (Night)
Fan
MON
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
TUE
WED
THU
FRI
SAT
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
SUN
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
Wired Remote Temperature Sensing
One remote temperature sensor can be installed indoor or 
outdoor and connected to the thermostat by a maximum 
cable length of 100 meters (300 feet). Terminals +, S and - on 
the terminal block allow connection of the remote sensor. 
The thermostat must have 24 VAC Common connection 
to terminal C for the remote sensor to operate. The 
remote sensor can be enabled or disabled in the Installer/
Configuration menu, item 29.
When remote sensor, Remote, is selected Off (factory 
default), no remote sensor is enabled. When remote sensor is 
selected On, the next step is to select the remote as indoor, 
Remote In, or outdoor, Outdoor Remote. If the remote is 
selected as Remote In, an additional step will be to select 
if the temperature shown on the display will be from the 
thermostat, LS On, or the remote sensor LS Off.
In normal operation, when a remote sensor is enabled the 
time digits of the display will alternate between the time and 
the remote temperature for three seconds each. Above the 
remote temperature will be Remote, for indoor sensor or 
Outdoor Remote, for outdoor sensor. If the remote sensor is 
an indoor sensor and the local display has been disabled, the 
temperature displayed as the room temperature will be the 
remote sensor temperature.
Sensing Range: 
Outdoor temperature range is -40
o
F to 140
o
F 
Indoor temperature range is 32
o
F to 99
 o
F
Averaging or Weighting Remote Sensors
The thermostat will weight or average the temperature of the 
indoor remote sensor with the local sensor in the thermostat 
for each program period. The averaging will be active only 
when the local sensor and the indoor remote sensor are both 
functional and enabled in the Installer/Configuration menu.
When the thermostat is in the Set Schedule mode, the weight 
of the indoor sensor will be shown in the current temperature 