Use and Care Manual

8
fore the heating or cooling cycle is satisfied and all stages
are turned off.
12. Select Compressor Lockout (CL) – Selecting (CL On)
will cause the thermostat to wait 5 minutes between cool-
ing cycles. This is intended to help protect the compressor
from short cycling. Some of the newer compressors have
a time delay built in and do not require this feature to be
activated in the thermostat. Your compressor manufactur-
er can tell you if this lockout feature is already present in
their system. When the thermostat compressor time delay
is activated, it will flash the set point for up to five minutes.
13. Select Continuous Display Lighting (dL) – In low
lighting conditions, display backlight improves the display
contrast. (See Table 1)
14. Select Temperature Display Adjustment 5 LO to 5 HI
This allows you to adjust the room temperature display
by -5°F to +5°F in 1° steps. Your thermostat was accu-
rately calibrated at the factory, however you have the
option to change the display temperature value to match
the previous thermostat, if you so prefer.
15. Select °F or °C Readout – Changes the display readout
to Celsius or Fahrenheit as required.
16. Select Audio Prompting (Beeper) On or Off – Factory
default setting is b, On. If you wish to turn off the beeper
select OFF.
17. Select Daylight Saving Time Calculation – This feature
will allow the thermostat to calculate the DST automatically
and apply it to the Real Time Clock display. Default is On.
18 & 19. Select Automatic Schedule – Not available if
configured for non-programmable. This feature allows
programming a “Comfort Temperature” into all program
periods with the Auto Schedule key. When Heat AS
(for Heat mode) or Cool AS (for Cool mode) is selected
On, the Auto Schedule feature is ready to be set. Off
indicates that the feature is not ready to be used or a
“Comfort Temperature" is already set. See Auto Schedule
in Programming section.
20 & 21. Select Cool Savings™ – Cool Savings™ provides an
energy saving temperature offset (from 1-6 degrees) under
peak cooling load conditions (high outdoor temperatures).
If selected on, Cool Savings™ becomes active when the
air-conditioner runs for periods of longer than 20 minutes.
When active, Cool Savings™ gradually offsets the indoor
temperature display downward. The first 1° of adjustment
will take one hour of continuous air conditioner run time
with subsequent 1° adjustments occurring with each ad-
ditional half hour of run time (ex for a 2° offset, the air con-
ditioner would need to run continuously for 1 ½ hours). The
offset is limited to the number of degrees you select from 1
up to 6. When an offset starts or is active, “Cool Savings”
will flash on the display.
The principle of this energy saving feature takes advantage
of the long air conditioning run times lowering the indoor
humidity allowing a slightly higher temperature to feel com-
fortable. As the peak load subsides, this feature also takes
advantage of the air conditioner's increased capacity
under more efficient conditions to gradually reduce the off-
set back to zero and return control to the selected setpoint
temperature. If Cool Savings is selected off, no tempera-
ture offset will occur.
22. Compressor Optimization – (Not available on earlier
models) CO provides a delay in circulator fan operation
after the compressor turns on or off. With CO selected
ON, when the compressor turns on (for a call for heat
in heat pump or a call for cool) the fan will be delayed
for five seconds before turning on to allow the air to be
heated or cooled. After the compressor turns off for call
for cool, the fan will continue to run for 20 seconds to
capture additional cooling from the system. If CO is set to
OFF, there will be no delay in fan operation.
23. Comfort Alert with Active Protection – (not available
on earlier models) Turn this feature ON to enable active
protection. This allows the thermostat to identify fault
codes sent by the Comfort Alert module when compres-
sor damage is possible and react to those codes by
turning the compressor off. Fault codes from the Comfort
Alert module will flash on the thermostat. (Refer to Com-
fort Alert Codes in Troubleshooting section.) If a Comfort
Alert module is not connected, or to disable active protec-
tion, turn this feature OFF. If a Comfort Alert module is
connected and this feature is turned OFF, the thermostat
will still receive and flash the fault codes from the Comfort
INSTALLER/CONFIGURATION MENU
Power Stealing Switches ON
(Factory Default)
Power Stealing Switches ON
(Factory Default)
Power Method
Backlight Option
OFF
(Factory Default)
Backlight Option
ON
Backlight Option
OFF
(Factory Default)
Backlight Option
ON
Battery Only (before thermostat installation or mV heat systems)
No Backlight Momentary Backlight No Backlight
Momentary
Backlight
Common Attached to "C" Terminal
Momentary Backlight Continuous Backlight Momentary Backlight Continuous Backlight
Battery with Power Stealing on "W/E" and "Y"
Momentary Backlight*
Continuous
Backlight*
No Backlight
Momentary
Backlight
Battery with "W/E" and "Y" but system does not allow Power
Stealing*
No Backlight*
Momentary
Backlight*
No Backlight
Momentary
Backlight
* Power Stealing Backlight Notes:
• If the sysrem is heat or cool only, or does not allow power
stealing on the thermostat terminals W/E and Y the back-
light may not operate continously or drop out when heat
or cool is running.
• If the power stealing switches (see page 2) on the back
of the thermostat are set to off the backlight will not be
continous.
• The display light will increase in brightness when a button
is pressed.
• On high impedance systems, the display light may dim
slightly when the thermostat is calling for heat or cool.
Table 1