Product Data Sheet September 2014 00813-0100-4001, Rev SA Rosemount 3051 Pressure Transmitter With the Rosemount 3051 Pressure Transmitter, you’ll gain more control over your plant. You’ll be able to reduce product variation and complexity as well as your total cost of ownership by leveraging one device across a number of pressure, level and flow applications. You’ll have access to information you can use to diagnose, correct and even prevent issues.
Rosemount 3051 September 2014 Setting the Standard for Pressure Measurement Proven best-in-class performance, reliability and safety Over 7 million installed Reference accuracy 0.04% of span Installed total performance of 0.14% of span 10-year stability of 0.
September 2014 Rosemount 3051 Industry leading capabilities extended to IEC 62591 (WirelessHART®) Cost effectively implement wireless on the industry's most proven platform Optimize safety with the industry's only intrinsically safe power module Eliminate wiring design and construction complexities to lower costs by 40-60% Quickly deploy new pressure, level and flow measurements in 70% less time Innovative, integrated DP Flowmeters Fully assembled, configured, and leak tested for out-of
Rosemount 3051 September 2014 Rosemount 3051C Coplanar™ Pressure Transmitter Rosemount 3051C Coplanar Pressure Transmitters are the industry standard for Differential, Gage, and Absolute pressure measurement. The Coplanar Platform enables seamless integration with manifolds, flow and level solutions.
September 2014 Rosemount 3051 Table 1. 3051C Coplanar Pressure Transmitters Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 Table 1. 3051C Coplanar Pressure Transmitters Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
September 2014 Rosemount 3051 Table 1. 3051C Coplanar Pressure Transmitters Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 Table 1. 3051C Coplanar Pressure Transmitters Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
September 2014 Rosemount 3051 Table 1. 3051C Coplanar Pressure Transmitters Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 (8) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments. (9) Not available with Wireless Output (code X). (10) Only available with Wireless Output (code X).
September 2014 Rosemount 3051 Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-Line Pressure Transmitters are the industry standard for Gage and Absolute pressure measurement. The in-line, compact design allows the transmitter to be connected directly to a process for quick, easy and cost effective installation.
Rosemount 3051 September 2014 Table 2. 3051T In-Line Pressure Transmitter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
September 2014 Rosemount 3051 Table 2. 3051T In-Line Pressure Transmitter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 Table 2. 3051T In-Line Pressure Transmitter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
September 2014 Rosemount 3051 Table 2. 3051T In-Line Pressure Transmitter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 (26) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, and IE. (27) Not valid with Alternate Process Connection S5. (28) The V5 option is not needed with T1 option; external ground screw assembly is included with the T1 option. (29) NACE compliant wetted materials are identified by Footnote 10. 16 www.rosemount.
September 2014 Rosemount 3051 Rosemount 3051CF Flowmeter Selection Guide Rosemount 3051CF Flowmeters combine the proven Rosemount 3051 Pressure Transmitter and the latest primary element technologies. All flowmeters are fully assembled, calibrated, configured, and leak tested for out-of-the-box installation and are available with wired or wireless capabilities to meet all of your application needs.
Rosemount 3051 September 2014 Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the T-shaped sensor design that delivers best in class accuracy and performance while meeting the needs of diverse process applications, whether it is high accuracy for precision control or high strength for severe flow applications. Main capabilities include: Up to 1.8% of flow rate accuracy Available in 2 to 96-in.
September 2014 Rosemount 3051 Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. 160 16-in. (400 mm) 180 18-in. (450 mm) 200 20-in. (500 mm) 240 24-in. (600 mm) 300 30-in. (750 mm) 360 36-in. (900 mm) 420 42-in. (1066 mm) 480 48-in. (1210 mm) 600 60-in. (1520 mm) 720 72-in.
Rosemount 3051 September 2014 Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Sensor size 1 Sensor size 1 — Line sizes 2-in. (50 mm) to 8-in. (200 mm) H 2 Sensor size 2 — Line sizes 6-in. (150 mm) to 96-in. (2400 mm) H 3 Sensor size 3 — Line sizes greater than 12-in.
September 2014 Rosemount 3051 Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Pressure testing P1(10) Hydrostatic Testing with Certificate PX(10) Extended Hydrostatic Testing Special cleaning P2 Cleaning for Special Services PA Cleaning per ASTM G93 Level D (Section 11.
September 2014 Rosemount 3051 Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
September 2014 Rosemount 3051 (4) Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output. (5) For local addressing and configuration, M4 (Local Operator Interface) is required. (6) Requires wireless options and engineered polymer housing.
Rosemount 3051 September 2014 Rosemount 3051CFC Compact Flowmeter Rosemount 3051CFC Compact Flowmeters provide a quick, reliable installation between existing raised face flanges. Depending on your application needs, you can reduce energy loss with the Compact Annubar or minimize straight run requirements with the Conditioning Orifice. Up to 1.8% of flow rate accuracy Available in 1/2 to 12-in.
September 2014 Rosemount 3051 Table 4. Rosemount 3051CFC Compact Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Primary element type N000 N040 N050 N065(4) H H Annubar Sensor Size 1 0.40 Beta Ratio 0.50 Beta Ratio 0.
Rosemount 3051 September 2014 Table 4. Rosemount 3051CFC Compact Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Installation accessories AB AC AD DG DH DJ JB JR JS ANSI Alignment Ring (150#) (Only required for 10-in. (250 mm) and 12-in. (300mm) line sizes) ANSI Alignment Ring (300#) (Only required for 10-in. (250 mm) and 12-in.
September 2014 Rosemount 3051 Table 4. Rosemount 3051CFC Compact Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 Table 4. Rosemount 3051CFC Compact Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
September 2014 Rosemount 3051 (22) Only valid with FOUNDATION fieldbus (output code F). (23) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option. (24) Only available with 4-20 mA HART Output (output code A) and Wireless output (output code X). www.rosemount.
Rosemount 3051 September 2014 Rosemount 3051CFP Integral Orifice Flowmeter Rosemount 3051CFP Integral Orifice Flowmeters enable highly accurate flow measurement in small line sizes. Integral Orifice utilize precision honed pipe section for increased accuracy and self-centering plate design to prevent alignment errors that magnify measurement inaccuracies in small line sizes. Up to 1.75% of flow rate accuracy Available in 1/2 to 11/2-in.
September 2014 Rosemount 3051 Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
September 2014 Rosemount 3051 Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
September 2014 Rosemount 3051 (5) Requires wireless options and engineered polymer housing. Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), and IECEx Intrinsic Safety (option code I7). (6) Only available with C6, E2, E5, I5, K5, KB and E8 approval. Not available with GE, GM, SBS, DA0, M4, D4, DZ, QT, HR5, HR7, CR, CS, CT. (7) Only available with Wireless Output (output code X).
Rosemount 3051 September 2014 Rosemount 3051L Level Transmitter The Rosemount 3051L Level Transmitter combines the performance and capabilities of Rosemount 3051 Transmitters with the reliability and quality of a direct mount seal in one model number. 3051L Level Transmitters offer a variety of process connections, configurations, and fill fluid types to meet a breadth of level applications.
September 2014 Rosemount 3051 Table 6. Rosemount 3051L Level Transmitter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. A6(6) 3-in./DN 80 316L SST 6-in./150 mm H (6) B0 4-in./DN 100 316L SST Flush Mount H B2(6) 4-in./DN 100 316L SST 2-in./50 mm H B4(6) 4-in./DN 100 316L SST 4-in./100 mm H (6) B6 4-in.
Rosemount 3051 September 2014 Table 6. Rosemount 3051L Level Transmitter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Mounting flange size, rating, material (high side) Size Rating Material W(6) DN 100 PN 10/16 per EN 1092-1 316 SST H 7(6) 4 in. ANSI/ASME B16.
September 2014 Rosemount 3051 Table 6. Rosemount 3051L Level Transmitter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. O-ring A H Glass-filled PTFE Housing material Conduit entry size A Aluminum ½–14 NPT H B Aluminum M20 × 1.5 H J SST ½–14 NPT H K SST M20 × 1.
Rosemount 3051 September 2014 Table 6. Rosemount 3051L Level Transmitter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
September 2014 Rosemount 3051 Table 6. Rosemount 3051L Level Transmitter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Rosemount 3051 September 2014 Table 6. Rosemount 3051L Level Transmitter Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
September 2014 Rosemount 3051 Specifications Performance specifications This product data sheet covers HART, Wireless, FOUNDATION fieldbus, and PROFIBUS PA protocols unless specified. Conformance to specification [±3 (Sigma)] Technology leadership, advanced manufacturing techniques, and statistical process control ensure specification conformance to at least ±3. Reference accuracy Stated reference accuracy equations include terminal based linearity, hysteresis, and repeatability.
Rosemount 3051 September 2014 Flow performance - flow reference accuracy(1) 3051CFC_P Compact Orifice Flowmeter – orifice type option P(2) Ranges 2-3 = 0.4 = 0.65 ±2.00% of Flow Rate at 8:1 flow turndown ±2.00% of Flow Rate at 8:1 flow turndown 3051CFP Integral Orifice Flowmeter Ranges 2-3 <0.1 0.1< <0.2 0.2< <0.6 0.6< <0.8 ±3.00% of Flow Rate at 8:1 flow turndown ±1.95% of Flow Rate at 8:1 flow turndown ±1.75% of Flow Rate at 8:1 flow turndown ±2.
September 2014 Rosemount 3051 Dynamic performance 4 - 20 mA HART(1) FOUNDATION fieldbus Typical HART transmitter response and PROFIBUS PA time protocols(3) Total Response Time (Td + Tc)(2): 3051C Ranges 2-5 Range 1 Range 0 3051T 3051L 100 ms 255 ms 700 ms 100 ms See Instrument Toolkit 152 ms 307 ms N/A 152 ms See Instrument Toolkit Transmitter Output vs.
Rosemount 3051 September 2014 Mounting position effects Models Mounting position effects 3051C 3051CA, 3051T Zero shifts up to ±1.25 inH2O (3,11 mbar), which can be calibrated out. No span effect. Zero shifts up to ±2.5 inH2O (6,22 mbar), which can be calibrated out. No span effect. With liquid level diaphragm in vertical plane, zero shift of up to ±1 inH2O (2,49 mbar). With diaphragm in horizontal plane, zero shift of up to ±5 inH2O (12,43 mbar) plus extension length on extended units.
September 2014 Rosemount 3051 Functional specifications Range and sensor limits Table 7. 3051CD, 3051CG, 3051CF, and 3051L Range and Sensor Limits Range(1) Minimum span 0 1 2 3 4 5 Range and sensor limits Lower (LRL) 3051CD, 3051CG, 3051CF, 3051L(2) 0.10 inH2O (0,24 mbar) 0.50 inH2O (1,24 mbar) 1.67 inH2O (4,15 mbar) 6.67 inH2O (16,58 mbar) 2.00 psi (137,89 mbar) 13.33 psi (919,01 mbar) Upper (URL) 3051CD differential 3051CF Flowmeters 3.00 inH2O (7,45 mbar) 25.00 inH2O (62,16 mbar) 250.
Rosemount 3051 September 2014 Service External power supply required. Standard transmitter (4-20mA) operates on 10.5-42.4 Vdc with no load Local operator interface The LOI utilizes a 2 button menu with internal and external configuration buttons. Internal buttons are always configured for Local Operator Interface. External Buttons can be configured for either LOI (option code M4), Analog Zero and Span (option code D4) or Digital Zero Trim (option code DZ).
September 2014 LCD transducer block The LCD transducer block is used to configure the LCD display meter. Analog input block The analog input (AI) function block processes the measurements from the sensor and makes them available to other function blocks. The output value from the AI block is in engineering units and contains a status indicating the quality of the measurement. The AI Block is widely used for scaling functionality.
Rosemount 3051 September 2014 Local operator interface Minimum load impedance The LOI utilizes a 2 button menu with external configuration buttons. 100 k (Vout wiring) Wireless (output code X) Optional 5-digit LCD display Output Overpressure limits IEC 62591 (WirelessHART), 2.4 GHz DSSS Wireless radio (internal antenna, WP5 option) Indication Rosemount 3051CD/CG/CF • Range 0: 750 psi (51,71 bar) Frequency: 2.400 - 2.
September 2014 Rosemount 3051 3051T In-Line Process Ranges 1-4: 11016 psi (759,53 bar) Range 5: 26016 psig (1793,74 bar) At atmospheric pressures and above. See Table 10. Table 10. 3051 Process Temperature Limits Failure mode alarm 3051CD, 3051CG, 3051CF, 3051CA HART 4-20 mA (output option code A) If self-diagnostics detect a sensor or microprocessor failure, the analog signal is driven either high or low to alert the user.
Rosemount 3051 Damping 4-20 mA HART September 2014 For 3051CFC, see 00813-0100-4485 Rosemount 405 Compact Orifice Plate For 3051CFP, see 00813-0100-4485 Rosemount 1195 Integral Orifice Analog output response to a step input change is user-enterable from 0.0 to 60 seconds for one time constant. This software damping is in addition to sensor module response time.
September 2014 Rosemount 3051 Table 12. 3051L Weights without Options Bolts Plated carbon steel per ASTM A449, Type 1 Austenitic 316 SST per ASTM F593 ASTM A193, Grade B7M alloy steel Alloy K-500 Flange DN 80/PN 40 DN 100/ PN 10/16 DN 100/ PN 40 Sensor module fill fluid Coplanar: silicone or Inert Halocarbon In-line: silicone or Fluorinert™ FC-43 Flush lb. (kg) 2-in. Ext. 4-in. Ext. 6-in. Ext. lb. (kg) lb. (kg) lb. (kg) 19.5 (8,8) 21.5 (9,7) 22.5 (10,2) 23.5 (10,6) 17.8 (8,1) 19.8 (9,0) 20.
Rosemount 3051 September 2014 3051 Product Certifications European Directive Information A copy of the EC Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EC Declaration of Conformity can be found at www.rosemount.com.
September 2014 Rosemount 3051 Europe E8 Special Conditions for Safe Use (X): 1. The apparatus is not capable of withstanding the 500 V insulation test required by EN60079-11. This must be taken into account when installing the apparatus. ATEX Flameproof and Dust Certificate: KEMA00ATEX2013X; Baseefa11ATEX0275X 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however care should be taken to protect it from impact or abrasion if located in Zone 0.
Rosemount 3051 September 2014 International E7 Special Conditions for Safe Use (X): IECEx Flameproof and Dust Certificate: IECEx KEM 09.0034X; IECEx BAS 10.0034X Standards: IEC60079-0:2011, IEC60079-1:2007-04, IEC60079-26:2006, IEC60079-31:2008 Markings: Ex d IIC T6/T5 Ga/Gb, T6(-50°C Ta +65°C), T5(-50°C Ta +80°C); Ex ta IIIC T95°C T500105°C Da (-20°C Ta +85°C) 1.
September 2014 Rosemount 3051 Brazil Certificate: UL-BR 13.0584X E2 INMETRO Flameproof Standards: ABNT NBR IEC60079-0:2008 + Errata 1:2011, ABNT NBR IEC60079-11:2009 Certificate: UL-BR 13.
Rosemount 3051 September 2014 hazardous location. When used in combustible dust environment, cable entry in accordance with IP66 or higher level should be applied. 3. Intrinsically Safe parameters: Input parameters HART Fieldbus/PROFIBUS FISCO Voltage Ui 30 V 30 V 17.5 V Current Ii 200 mA 300 mA 380 mA Power Pi 0.9 W 1.3 W 5.32 W 0.012 μF 0 μF <5 nF 0 mH 0 mH <10 μH 4. Obey the warning “Keep tight when the circuit is alive.” 5.
September 2014 N3 Rosemount 3051 limitation-Selection, installation and maintenance” GB15577-2007 “Safety regulations for dust explosion prevention and protection” Technical Regulations Customs Union (EAC) China Type n EM, IM, KM Certificate: GYJ101111X Standards: GB3836.1-2000, GB3836.8-2003 Markings: Ex nA IIC T5 (-40°C Ta +70°C) Special Conditions for Safe Use (X): 1.
Rosemount 3051 September 2014 Application: Thread Adapter Thread Sizes Male thread Identification mark M20 x 1.5 – 6H M20 1/2 - 14 NPT 1/2 – 14 NPT 3/4 - 14 NPT 3/4 – 14 NPT Female thread Identification mark M20 x 1.5 – 6H M20 1/2 - 14 NPT 1/2 – 14 NPT PG 13.5 PG 13.5 Location classes 2. The blanking plug shall not be used with an adapter. 3. Blanking Plug and Threaded Adapter shall be either NPT or Metric thread forms. G½ and PG 13.
September 2014 Rosemount 3051 FCC and IC CSA - Canadian Standards Association This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons.
Rosemount 3051 September 2014 Pipe I.D. Range Codes For pipes with an Inner Diameter (I.D.) Range/Pipe Wall Thickness not found in this table or with a line size greater than 12-in. (300 mm), choose option code Z and specify the exact pipe dimensions (I.D. and Pipe Wall Thickness) on the Configuration Data Sheet (see document number 00806-0100-4010). The Emerson Process Management sizing program will determine this code, based on the application piping. Line size Nominal 2-in. (50 mm) 21/2-in. (63.
Sensor Size 2 Sensor Size 1 Sensor Z2 Sensor Size 1 Sensor Size 2 Sensor Size 1 September 2014 6-in. (150 mm) 6-in. (150 mm) 7-in. (180 mm) 7-in. (180 mm) 8-in. (200 mm) 8-in. (200 mm) 10-in. (250 mm) 12-in. (300 mm) Rosemount 3051 6.93-in. (176.02 mm) 6.93-in. (176.02 mm) 7.93-in. (201.42 mm) 7.93-in. (201.42 mm) 9.688-in. (246.08 mm) 9.688-in. (246.08 mm) 11.75-in. (298.45 mm) 13.0375-in. (331.15 mm) www.rosemount.com 060 060 070 070 080 080 100 120 5.250 to 5.472-in.
Rosemount 3051 September 2014 Rosemount 3051 Dimensional Drawings(1) Figure 1. Rosemount 3051C Exploded View F E D C B A G H I J K N L O M P Q A. Cover B. Cover O-ring C. Terminal Block D. Electronics Housing E. Configuration Buttons Cover F. Local Configuration Buttons (1) 66 G. Electronics Board H. Name Plate I. Housing Rotation Set Screw (180 degree maximum rotation without further disassembly) J. Sensor Module K. Coplanar Flange L. Drain/Vent Valve M. Flange Adapters N. Process O-Ring O.
September 2014 Rosemount 3051 Figure 2. Rosemount 3051C Coplanar Flange 4.29 (109) 4.09 (104) 7.12 (181) 6.55 (166) Dimensions are in inches (millimeters). Figure 3. 3051 Wireless Housing with Coplanar Flange 4.196 (106.6) 5.49 (139) 7.41 (188) Dimensions are in inches (millimeters). www.rosemount.
Rosemount 3051 September 2014 Figure 4. Rosemount 3051C Coplanar Flange with Rosemount 305RC3 3-Valve Coplanar Integral Manifold 6.75 (171) 5.50 (140) Max Open 9.20 (234) Max Open Dimensions are in inches (millimeters). 68 www.rosemount.
September 2014 Rosemount 3051 Figure 5. Coplanar Flange Mounting Configurations with Optional Bracket (B4) for 2-in. Pipe or Panel Mounting A 2.81 (71) B PANEL MOUNTING 3.35 (85) 6.20 (157) 2.81 (71) 4.73 (120) C D PIPE MOUNTING 3.35 (85) 6.25 (159) 3.50 (89) A. 5/16 - 18 Bolts (not supplied) B. 3/8–16 Bolts Dimensions are in inches (millimeters). www.rosemount.com C. 2-inch U-Bolt D.
Rosemount 3051 September 2014 Figure 6. Rosemount 3051C Coplanar with Traditional Flange 4.09 (104) 1.63 (41) 2.13 (54) A 1.16 (29) 3.40 (86) 1.10 (28) A. Flange Adapters (optional) Dimensions are in inches (millimeters). Figure 7. Rosemount 3051C Coplanar with Rosemount 305RT3 3-Valve Traditional Integral Manifold 6.28 (159) A 3.63 (92) 0.91 (23) 3.50 (89) 1.10 (28) 6.38 (162) 2.13 (54) 2.52 (64) A. 1/2–14 NPT Flange Adapter (optional) Dimensions are in inches (millimeters). 70 www.
September 2014 Rosemount 3051 Figure 8. Traditional Flange Mounting Configurations with Optional Brackets for 2-in. Pipe or Panel Mounting Panel mounting bracket (option B2/B8) 2.62 (67) 2-in. pipe mounting bracket (option B1/B7/BA) 9.27 (235) 2.62 (67) A 6.65 (169) 0.93 (24) 4.12 (105) 2.81 (71) 2-in. pipe mounting bracket (option B3/B9/BC) 6.65 (169) 4.85 (123) 1.10 (28) 3.40 (86) 1.75 (44) A. 5/16-18 Bolts (not supplied) Dimensions are in inches (millimeters). www.rosemount.
Rosemount 3051 September 2014 Figure 9. Rosemount 3051T Dimensional Drawings 4.09 (104) 4.29 (109) R1-4: 7.22 (183) R5: 7.32 (186) Dimensions are in inches (millimeters). Figure 10. 3051T Wireless Housing Dimensional Drawings 4.20 (107) 5.49 (139) R1-4: 7.56 (192) R5: 7.66 (195) A A. U-Bolt Bracket Dimensions are in inches (millimeters). 72 www.rosemount.
September 2014 Rosemount 3051 Figure 11. Rosemount 3051T with Rosemount 306 2-Valve I Integral Manifold 4.13 (105) 4.88 (124) 6.25 (159) Max Open Dimensions are in inches (millimeters). Figure 12. Rosemount 3051T Typical Mounting Configurations with Optional Mounting Bracket Pipe mounting Panel mounting 6.15 (156) 3.49 (89) 6.15 (156) 2.81 (71) 4.78 (121) Dimensions are in inches (millimeters). www.rosemount.
Rosemount 3051 September 2014 Figure 13. Rosemount 3051CFA Pak-Lok Annubar Flowmeter(1) Front view Side view Top view D C B A Table 14. Rosemount 3051CFA Pak-Lok Annubar Flowmeter Dimensional Data (Maximum Dimensions) Sensor size A B C D 1 8.50 (215.9) 15.60 (396.9) 9.00 (228.6) 6.00 (152.4) 2 11.00 (279.4) 18.10 (460.4) 9.00 (228.6) 6.00 (152.4) 3 12.00 (304.8) 19.10 (485.8) 9.00 (228.6) 6.00 (152.4) Dimensions are in inches (millimeters).
September 2014 Rosemount 3051 Figure 14. Rosemount 3051CFC Compact Orifice Flowmeter Orifice plate front view Orifice plate top view Conditioning orifice plate (Primary element type code C) Compact orifice plate (Primary element type code P) Orifice plate side view Primary element type Type P and C A B 5.62 (143) Transmitter Height + A Transmitter height C D 6.27 (159) 7.75 (197) - closed 8.25 (210) - open 6.00 (152) - closed 6.25 (159) - open Dimensions are in inches (millimeters). www.
Rosemount 3051 September 2014 Figure 15. Rosemount 3051CFP Integral Orifice Flowmeter Side view Bottom view Front view 8.80 (223.46) 10.30 (261.81) 6.30 (160.55) A 5.30 (134.51) K Downstream J Upstream A. B.D. (Bore Diameter) Dimensions are in inches (millimeters).
September 2014 Rosemount 3051 Figure 16. Rosemount 3051L Dimensional Drawings 2-in. flange configuration (flush mount only) 3- and 4-in. flange configuration 4.09 (104) 4.09 (104) D C A A E B A. Flange Thickness B. See Table 15. C. Extension Diameter B D. O.D. Gasket Surface E. 2-in., 4-in., or 6-in. extension (only available with 3-in. and 4-in., DN80, and DN100 flange configurations) Optional flushing connection ring (lower housing) Diaphragm assembly and mounting flange E G I F D H D.
Rosemount 3051 September 2014 Diaphragm assembly and mounting flange 5.13 (130) 4.29 (109) 6.80 (173) 7.10 (181) 8.20 (209) Dimensions are in inches (millimeters). 78 www.rosemount.
September 2014 Rosemount 3051 Table 15. 3051L Dimensional Specifications Class(1) ASME B16.5 (ANSI) 150 ASME B16.5 (ANSI) 300 ASME B16.5 (ANSI) 600 DIN 2501 PN 10–40 DIN 2501 PN 25/40 DIN 2501 PN 10/16 Pipe size Flange thickness A Extension Bolt circle Outside No. of Bolt hole diameter(1) diameter H diameter J bolts diameter D O.D. gasket surface E 2 (51) 0.69 (18) 4.75 (121) 6.0 (152) 4 0.75 (19) N/A 3.6 (92) 3 (76) 0.88 (22) 6.0 (152) 7.5 (191) 4 0.75 (19) 2.58 (66) 5.
Rosemount 3051 September 2014 Options Standard configuration Custom configuration(1) Unless otherwise specified, transmitter is shipped as follows: If Option Code C1 is ordered, the customer may specify the following data in addition to the standard configuration parameters.
September 2014 Rosemount 3051 Commissioning tag(1) M5 Digital Display A temporary commissioning tag is attached to all transmitters. The tag indicates the device ID and allows an area for writing the location. Optional Rosemount 304, 305 or 306 Integral Manifolds Factory assembled to 3051C and 3051T transmitters. Refer to the following Product Data Sheet (document number 00813-0100-4839 for Rosemount 304 and 00813-0100-4733 for Rosemount 305 and 306) for additional information.
Rosemount 3051 September 2014 Rosemount 3051C Traditional Flange Bracket Options B1 Bracket for 2-in. Pipe Mounting • B2 Bracket for mounting on 2-in. pipe • Carbon steel construction with carbon steel bolts • Coated with polyurethane paint Bracket for Panel Mounting • B3 Bracket for mounting transmitter on wall or panel • Carbon steel construction with carbon steel bolts • Coated with polyurethane paint Flat Bracket for 2-in.
September 2014 www.rosemount.
Rosemount 3051 Product Data Sheet 00813-0100-4001, Rev SA Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906-8888 F (952) 906 8889 www.rosemount.com Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 Tel +65 6777 8211 Fax +65 6777 0947 Service Support Hotline : +65 6770 8711 Email : Enquiries@AP.EmersonProcess.com www.rosemount.