Brochures and Data Sheets

Avtron K711/K711A/K711L
Resistive Load Bank - 5 to 1250 KW
Testing Your Emergency Standby
Generator with a Load Bank Means
Reliability When it Matters Most.
Economical - Uses Engine Air
for Cooling
Reduces “Wet-Stacking” Problems
Provides Load for Routine
Generator Testing
Corrosion Resistant Aluminized
Steel Frame
Includes Lifting Eyes and Duct
Flange for Easy Installation
Key Features
Superior Avtron quality combined with
simple operation and maintenance will
provide years of trouble free service.
Avtron’s extensive line of Load Bank and
Industrial Resis tor Products are solid
performers used throughout the world.
For total technical support or additional
information, please contact Avtron at
(216) 573-7600 or LBsales@Emerson.com.
Quality System Certified to ISO 9001
The Avtron Model K711 Load Bank are intended for use as
a supplemental load for lightly loaded engine gen sets.
The Avtron K711/K711A/K711L load banks are designed for duct or radiator mounting and
are available in a variety of frame dimensions. The load banks are permanently mounted to
the front of the engine generator and sized to match the radiator or exhaust duct opening.
The K711 load banks utilize the engine cooling air rather than an internal cooling fan found
on conventional load banks.
The primary cause of premature diesel engine failure is “wet-stack ing” which is literally
“wet” unburned fuel accumulating in the engine exhaust (“stack”), due to under-loading of
the generator. Diesel engines that are lightly loaded or allowed to idle for long periods never
reach their recommended full operating temperature. Over time, this unburned fuel coats
the combustion chamber and pistons with a thick coating of tar and carbon build-up, reducing
efficiency and life span of the engine considerably. A supplemental radiator load bank helps to
“burn-off” these harmful carbon deposits, greatly increasing engine life.
These units are offered in 208, 240, 480 or 600 volt versions (at 60 Hz) or 380, 400 or 416
volt versions (at 50 Hz). Load rating varies and ranges between 5 and 1250 KW. Most engine
manufacturers recommend sizing the radiator load bank to 40-60% of engine nameplate
rating to eliminate “wet-stacking” problems.
The K711 load bank is controlled from a built-in control panel which contains the individual
load-step toggle switches. The control panel is also available sized for standard 19" [482.6]
rack mounting when remote installation of the panel is desired.
The K711 family is intended for use as a supplemental load for lightly loaded engine generator sets.
The load bank utilizes the engine cooling air to cool the resistive load elements.
K711 500 KW Resistive
Radiator Mount Avtron
Load Bank.