LP-Gas Equipment Buyers Guide LP-31 The Industry Leader for Durability and Quality
Fisher® LP-Gas Equipment Global Technology Leadership Our commitment to providing customers with customized solutions, dependable products, along with uncompromising quality standards and exceptional service is a tradition dating back to our beginnings in 1880, when William Fisher invented the first regulator. Today, Fisher LP-Gas Equipment is a part of Emerson Process Management’s Regulator Technologies Division, the World Leader in valve and regulator design and manufacturing. Emerson, a $24.
TaBle of conTenTs REGULATOR APPLICATION MAP . . . . . . . . . . . . . . . . . . . . . . . . . 2 INTERNAL VALVES VALVE APPLICATION MAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 INTERNAL VALVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 REGULATOR SELECTION GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . .6 VALVE SELECTION GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 ACCESSORIES SELECTION GUIDE . . . . . . . . . . . . . . .
lP-gas RegulaToRs Application: Regulators R622 SecondStage Introduction The regulator truly is the heart of an LP-Gas installation. It must compensate for variations in tank pressure from 8 to 250 psig / 0.
lP-gas RegulaToRs 17.2 bar and deliver a constant outlet pressure of LP-Gas typically at 11 inches w.c. / 27 mbar to consuming appliances. The regulator must deliver this pressure despite the intermittent use of the appliances. In propane service, NFPA 58 requires Two-Stage regulation on all fixed piping systems that serve 14 inches w.c. / 35 mbar appliance systems (normally operated at 11 inches w.c. / 27 mbar pressure).
lP-gas ValVes Application: Valves and Relief Valves C477 Jet Bleed Internal™ Valve C484-24 Jet Bleed Internal™ Valve C483-24 with P723 Rotary Actuator N550 with P539A Pneumatic Actuator H722 Relief Valve C407-10 with P731 Internal Valve with Rotary Actuator 4
lP-gas ValVes Introduction The valves provide a means of withdrawing and filling product with or without pumps and compressors. These valves may be used as primary shutoff valves, excess flow valves and back check valves. No one offers a more complete line of LP-Gas Equipment to match your job specification.
RegulaToRs QuicK selecTion guide MAXIMUM INLET PRESSURE 250 psig / 17.2 bar OUTLET PRESSURE RANGE RATED CAPACITY*(1) TYPE NUMBER 3 to 120 psig / 0.21 to 8.3 bar 1.2M BTU per hour / 13.5 SCMH 67C Series Page 30 250 psig / 17.2 bar 3 to 100 psig / 0.21 to 6.9 bar 5.25M BTU per hour / 59.1 SCMH 64 Series Page 31 250 psig / 17.2 bar COMMERCIAL/ INDUSTRIAL HIGH-PRESSURE REGULATORS 5 to 40 psig / 0.35 to 2.8 bar 20.95M BTU per hour / 235 SCMH 627 Series Page 32 250 psig / 17.
RegulaToRs QuicK selecTion guide MAXIMUM INLET PRESSURE 125 psig / 8.6 bar OUTLET PRESSURE RANGE RATED CAPACITY*(1) TYPE NUMBER 3.5 inches w.c. to 2 psig / 9 mbar to 0.14 bar 3.9M BTU per hour / 43.8 SCMH(3) CS200 Series Page 36 125 psig / 8.6 bar 3.5 inches w.c. to 5.5 psig / 9 mbar to 0.38 bar 8.9M BTU per hour / 100 SCMH(2) CS400 Series Page 36 125 psig / 8.6 bar COMMERCIAL/ INDUSTRIAL LOW-PRESSURE REGULATORS 60 psig / 4.1 bar 8 inches w.c to 5.5 psig / 20 mbar to 0.
RegulaToRs QuicK selecTion guide MAXIMUM INLET PRESSURE OUTLET PRESSURE SETTING/SETPOINTS RATED CAPACITY*(1) TYPE NUMBER 250 psig / 17.2 bar 10 psig / 0.69 bar +/- 1 psig / 69 mbar nominal outlet setting (non-adjustable) 1.1M BTU per hour / 12.4 SCMH R122H Series 5 or 10 psig / 0.35 or 0.69 bar standard setpoints 2.4M BTU per hour / 27.0 SCMH FIRST-STAGE REGULATORS 250 psig / 17.2 bar MAXIMUM INLET PRESSURE 10 psig / 0.
RegulaToRs QuicK selecTion guide MAXIMUM INLET PRESSURE STANDARD SETPOINT RATED CAPACITY*(1) TYPE NUMBER 10 psig / 0.69 bar 2 psi / 0.14 bar 1.68M BTU per hour / 18.9 SCMH R622E Series 2-PSI SERVICE REGULATORS Page 26 10 psig / 0.69 bar 2 psi / 0.14 bar 1.5M BTU per hour / 16.9 SCMH R652E Series Page 26 MAXIMUM INLET PRESSURE 250 psig / 17.2 bar STANDARD SETPOINT First-Stage: Approximately 10 psig / 0.69 bar (non-adjustable) RATED CAPACITY*(2) TYPE NUMBER 550,000 BTU per hour / 6.
RegulaToRs QuicK selecTion guide MAXIMUM INLET PRESSURE 250 psig / 17.2 bar STANDARD SETPOINT First-Stage: Approximately 10 psig / 0.69 bar (non-adjustable) TYPE NUMBER 500,000 BTU per hour / 5.6 SCMH R232E Series Page 28 Second-Stage: 2 psi / 0.14 bar INTEGRAL TWO-PSIG REGULATORS 250 psig / 17.2 bar First-Stage: Approximately 10 psig / 0.69 bar (non-adjustable) Second-Stage: 2 psi / 0.14 bar BACKPRESSURE REGULATORS/ RELIEF VALVES RATED CAPACITY*(3) 900,000 BTU per hour / 10.
ValVes and Relief ValVes QuicK selecTion guides MAXIMUM INLET PRESSURE (BODY RATING) STANDARD SETPOINTS CAPACITY* TYPE NUMBER 480 psig / 33.1 bar 85 to 375 psig / 5.9 to 26 bar Up to 47,164 SCFM / 84,170 SCMH Type 63EGLP Page 67 480 psig / 33.1 bar 125 to 312 psig / 8.6 to 21.5 bar INTERNAL/EXTERNAL RELIEF VALVES 480 psig / 33.1 bar 420 psig / 29.0 bar 125 to 312 psig / 8.6 to 21.5 bar 35 to 350 psig / 2.4 to 23.
ValVes and Relief ValVes QuicK selecTion guides PRESSURE RATING EXCESS FLOW SPRING CAPACITY* 400 psig / 27.6 bar WOG 30 to 80 GPM / 113 to 302 l/min 19,200 SCFH / 544 SCMH Propane TYPE NUMBER C407-10 Series Page 46 400 psig / 27.6 bar WOG 60 to 460 GPM / 227 to 1741 l/min 178,000 SCFH / 5040 SCMH Propane C471-16, -24 Jet Bleed Internal™ Series Page 46 INTERNAL VALVES 400 psig / 27.6 bar WOG 400 psig / 27.
ValVes and Relief ValVes QuicK selecTion guides SEAT CONSTRUCTION PRESSURE RATING Soft Seat and Metal Seat 250 psi / 17.2 bar BACK CHECK VALVES Soft Seat 400 psig / 27.6 bar WOG CAPACITY* 254 GPM / 961 l/min Propane Up to 1620 GPM / 6132 l/min Propane TYPE NUMBER G100 Series Page 70 G200 Series Page 70 BODY SIZES AND END CONNECTION STYLE MAXIMUM INLET PRESSURE 1-1/4, 2, or 3-inch FNPT 400 psig / 27.6 bar EMERGENCY SHUTOFF VALVES 2-inch FNPT 400 psig / 27.
ValVes and Relief ValVes QuicK selecTion guides SELECTION DESCRIPTION Globe Valve (Heavy Duty Version) MAXIMUM OPERATING PRESSURE BODY SIZES AND END CONNECTION STYLES TYPE NUMBER 400 psig / 27.6 bar 1/2 to 3-inch FNPT and 3-inch / DN 80 CL300 RF Flange N301, N310 Series Page 69 GLOBE AND ANGLE VALVES Globe Valve (Economy Version) 400 psig / 27.6 bar 1/2 to 3/4-inch FNPT N350 Series Page 69 Angle Valve (Heavy Duty Version) 400 psig / 27.
ValVes and Relief ValVes QuicK selecTion guides PRODUCT/ FUNCTION SELECTION INFORMATION TYPE NUMBER Excess Flow Valve Brass or Steel body in a variety of Inlet and Outlet Connection Sizes and Styles; Up to 10.7 psi / 0.
lP-gas eQuiPMenT and accessoRies PRODUCT/ FUNCTION SELECTION INFORMATION TYPE NUMBER Screened Vents for Regulator 1/4-Inch FNPT to 1-Inch MNPT Y602 Series Page 43 Regulator Mounting Brackets Triangular, Bowtie, or Strap Design Type P100 Page 44 Test Pressure Gauge for Appliance Line Pressure REGULATOR ACCESSORIES 1/4-Inch NPT or Female Hose 50 Series Page 44 Pressure Gauge Adjustable Orifice Reamer 1/4-Inch MNPT; 0 to 400 psi / 0 to 27.6 bar; Ranges in MPa, kg/cm2, Bar Drill Size No.
lP-gas eQuiPMenT and accessoRies PRODUCT/ FUNCTION SELECTION INFORMATION TYPE NUMBER Liquid Transfer Valve 3/4 by 3/4-Inch MNPT Type M455 Page 71 Rotary Level Gauge for Stational or Mobile Tank 68 to 140-Inch / 1727 to 3556 mm Lengths Type J31 Page 74 Liquid Level Vent Valves 3/4-Inch MNPT for FNPT Connection; with or without Pressure Gauge J400 Series Page 74 BULK STORAGE TANK AND VALVE ACCESSORIES Container (Tank) Thermometer 1/2-Inch MNPT; -40 to 120°F / -40 to 49°C J700 Series Page 74 Fe
lP-gas eQuiPMenT and accessoRies PRODUCT/ FUNCTION SELECTION INFORMATION O-ring for Male Adaptors For 2-1/4 or 3-1/4-Inch Adaptors to Give a Better Seal than Washers Adaptor Caps BULK STORAGE TANK AND VALVE ACCESSORIES POL Filler Coupling TYPE NUMBER T12655T0012 / 1H291706562 Page 75 2-1/4 through 4-1/4-Inch Female ACME by 1-3/4 through 3-1/4-Inch Male ACME Type M611 Soft-Nose Male POL by 1/4-Inch MNPT Type M390 Page 75 Page 75 Filler Valve Adaptor 18 For Filler Valves with 1-3/4-Inch Male A
lP-gas eQuiPMenT and accessoRies PRODUCT/ FUNCTION SELECTION INFORMATION TYPE NUMBER Swivel POL Adaptor with Metal Seats Straight or Angle Male POL by 1/4-Inch MNPT Type M318 Auxiliary Remote Cable Release for Internal Valves With 25 or 50-Feet / 7.6 or 15.
lP-gas eQuiPMenT and accessoRies PRODUCT/ FUNCTION SELECTION INFORMATION TYPE NUMBER Pneumatic Actuator For Use with C407-10 Series Only Types P389 and P731 Page 60 Pneumatic Actuator For Type C484-24 Jet Bleed Internal™ Valve Types P613 and P713 Page 60 BULK STORAGE TANK AND VALVE ACCESSORIES Pneumatic Actuator For Type C483-24 Jet Bleed Internal™ Valve Types P623 and P723 Page 60 Pneumatic Actuator For Types C471 and C477 Jet Bleed Internal™ Valves (2 and 3-Inch NPT Sizes) Types P639 and P7
lP-gas eQuiPMenT and accessoRies PRODUCT/ FUNCTION Fuse Plug Protective Caps for Relief Valves SELECTION INFORMATION TYPE NUMBER 208 to 220°F / 98 to 104°C Melting Temperature, Available in 1/8 and 1/4-inch MNPT Sizes T1140399982/ T1033699982 For Types H110 through H174 Valves Type P206 Page 60 Page 68 Seals and Plugs for Female ACME Threads 1-1/4 to 4-1/4-Inch Male ACME Types M178, M535-34 Page 76 Female ACME Caps Hand or Wrench Installation Clamp Hose Couplings Swivel or Standard: 1/2-Inch
Real World Conditions Demand Fisher Solutions ® TYPE R232A TYPE R232E TYPE R632A • Flow Tested at -40°F for Functional Performance • Designed to Resist Gas Impurities TYPE R632E • New Full-Size 2-psig Model • New Compact 2-psig Model — an Industry First The real world isn’t always reliable. Fortunately, Fisher is.
TWo-sTage sYsTeM FIRST–STAGE REGULATOR USUALLY 10 psig / 0.69 bar SECOND–STAGE REGULATOR 11 INCHES W.C. / 27 mbar Figure 1. Two-Stage Regulation, One at Tank and One at Building, Reduce Pressure Down to Burner Pressure (11 inches w.c. / 27 mbar) Two-Stage Systems Five Reasons to Two-Stage Regulator Technologies Fisher brand makes the LP-Gas industry’s largest variety of First and Second-Stage regulators for domestic and commercial/industrial applications.
First-stage regulators TYPE R622H TYPE R122H Types R122H and R622H First-Stage Regulators are Underwriters Laboratories (UL®) listed regulators designed for Two-Stage LP-Gas Regulator systems. These First-Stage regulators reduce tank pressure to a lower pressure (usually 10 psig / 0.69 bar) for a Second-Stage regulator. Fisher® brand First-Stage regulators are painted red for easy identification. Vents are screened with standard orientation over the outlet.
seCond-stage regulators TYPE R222 TYPE HSRL TYPE R642 TYPE R652 TYPE R622 Types R222, R622, R642, R652 and HSRL Second-Stage regulators are Underwriters Laboratories (UL®) listed regulators designed to reduce the outlet pressure from a First-Stage regulator, usually 10 psig / 0.69 bar to 11 inches w.c. / 27 mbar, in domestic installations. Vents are screened with standard orientation over the inlet, but other orientations are available.
two-psi regulators TYPE R652E TYPE R622E Types R622E and R652E, Two-psi Service Regulators, are designed for Two-psi LP-Gas Regulator Systems and listed by Underwriters Laboratories (UL®). These units are installed downstream from a First-Stage regulator and reduce an inlet pressure of 10 psig / 0.69 bar to a nominal 2 psig / 0.14 bar outlet pressure. Two-psi Service Regulators are designed for domestic applications that supply 2 psig / 0.14 bar LP-Gas to a line regulator located inside the building.
integral two-stage regulators TYPE R232A Integral Two-Stage regulators combine a First-Stage regulator and a Second-Stage regulator into one compact unit. Recommended for installations where piping distance is short, integral Two-Stage regulators provide all of the advantages of Two-Stage regulation (refer to page 23). Fisher® brand integral Two-Stage regulators are color coded gray for easy identification. Vents are screened with standard Second-Stage vent orientation over the outlet.
integral two-psi regulators TYPE R232E Integral Two-psi regulators combine a First-Stage regulator and a Second-Stage, Two-psi regulator into one compact unit. Recommended for installations where piping distance is short, integral Two-Stage, Two-psi regulators provide all of the advantages of Two-Stage regulation (refer to page 23). Fisher® brand integral Two-Stage, Two-psi regulators are color coded gray with a white cap and white UV rated cover for easy identification.
automatiC CHangeover regulators Commercial Automatic Changeover Regulators Designed for large capacity multi-cylinder or tank installations, these regulators are used on applications such as bakeries, motels, restaurants and grain dryers. The manifold portion of the assembly consists of two 64 Series regulators and a direct mounted 803 Series indicator. Temperature rating for the Type 64SR-122 is -20 to 150°F / -29 to 66°C.
CommerCial/industrial HigH-pressure regulators TYPE 67CW TYPE 67CH TYPE 67CD TYPE 67CN 67C Series Suitable for liquid or vapor service, the 67C Series high-pressure (pounds-to-pounds) regulators are used on a variety of applications. All types within the series have a 1/4-inch FNPT side outlet in which a pressure gauge (J500 Series) can be installed. The compact size of the 67C Series regulators make them particularly useful on installations where space is limited.
CommerCial/industrial HigH-pressure regulators 64 SERIES 64 Series High-pressure (pounds-to-pounds) regulators usually reduce tank pressure to an intermediate pressure for use by another regulator. They may be used as high-pressure regulators on distribution systems when used in conjunction with a First-Stage downstream regulator. The Type 64SR may be used for First-Stage when set at 10 psig / 0.69 bar.
CommerCial/industrial direCt-operated HigH-pressure regulators TYPE 627 For Commercial and Industrial high-pressure applications like factories, office building, restaurants, etc., Regulator Technologies has a wide variety of products. For ease of reference, only the most popular commercial and industrial regulators are shown in these pages. Other orifice sizes, body sizes and outlet pressure ranges are available.
Commercial/Industrial Direct-Operated High-Pressure Regulators UL® Listed Type 627 Constructions TYPE NUMBER CAPACITIES(1) PROPANE ORIFICE SIZE Inch mm 3/8 9.5 BTU / hour SCMH 627-5810 6,080,000 68.4 627-5810V 6,080,000 68.4 627-6210 10,755,000 121 627-6210V 10,755,000 121 627-7710 10,773,000 121 627-7710V 10,773,000 121 INLET AND OUTLET CONNECTIONS OUTLET PRESSURE RANGE SETPOINT MAXIMUM OPERATING INLET PRESSURE psig bar psig bar psig bar 5 to 20 0.34 to 1.4 10 0.
CommerCial/industrial pilot-operated HigH-pressure regulators For Commercial and Industrial high-pressure applications, such as distributed community systems, factories, office buildings, restaurants, Regulator Technologies has a wide variety of products and solutions. For ease of reference, only the most popular commercial and industrial regulators are shown on these pages. Other orifice sizes, body sizes and outlet pressure ranges are available.
CommerCial/industrial pilot-operated HigH-pressure regulators Type 1098 - The Type 1098-EGR regulator provides large capacities for use in large commercial applications and large distributed community systems. Designed to handle loads from 170,000,000 BTU / 1910 SCM (2-inch size) to in excess of 1,000,000,000 BTU / 11,234 SCM (4-inch size) and rated to 75 psig / 5.2 bar for Maximum Outlet Pressure, the Type 1098H is a regulator unmatched in performance in the LP-Gas Industry.
CommerCial low-pressure regulators TYPE CS200 TYPE CS400 Regulator Technologies has a wide range of low-pressure regulators to meet almost any commercial or industrial application. For ease of reference, only the most popular commercial and industrial regulators are shown on this page. Other orifice sizes, body sizes and outlet pressure ranges are available. See the product guides on pages 37 and 39.
Commercial Low-Pressure Regulators Type CS200 Selection Guide Base Sensing RELIEF ORIFICE REGULATOR SETPOINTS Body option SIZE Code Description CODE DESCRIPTION CODE DESCRIPTION CODE CODE Inch / mm Inch w.c. / mbar CODE CS200 Basic I Internal N None 1 1/8 / 3.2 A 3.5 to 5 / 9 to 12 C1 R Internal 2 3/16 / 4.8 B 4.5 to 6.5 / 11 to 16 C3 3 1/4 / 6.4 C 6 to 8 / 15 to 20 C6 5 3/8 / 9.5 D 7.
CommerCial serviCe overpressure proteCtion Type CS403 with Integral True-Monitor™ Protection 1-1/4-inch FNPT to 2-inch FNPT Body Sizes (2-inch / DN 50, CL150 Flange Available) 7.65 to 8.44M BTU per hour / 85.9 to 94.8 SCMH Internal Registration Type CS403: Combines operation of a conventional two-regulator wide-open monitor set into one body. During normal operation, the monitor is in a wide open state at a setpoint higher than the primary regulator.
Commercial Service Overpressure Protection Type CS403 Selection Guide base sensing RELIEF ORIFICE REGULATOR SETPOINTS body option code description CODE DESCRIPTION CODE DESCRIPTION CODE SIZE, Inch / mm CODE Primary - Monitor Inch w.c. / mbar CODE DESCRIPTION CS403 Integral Monitor I Internal N None 2 3/16 / 4.8 D 11 / 27 - 21 / 52 D2 1-1/4-inch FNPT, Ductile Iron E External T Token 3 1/4 / 6.4 H 2 psig / 0.14 bar 2.5 psig / 0.
industrial serviCe low-pressure regulators TYPE 133H OR 133L TYPE 99L TYPE 299H Regulator Technologies has a wide range of low-pressure regulators to meet almost any commercial or industrial application. For ease of reference, only the most popular commercial and industrial regulators are shown on this page. Other orifice sizes, body sizes and outlet pressure ranges are available.
Monitor Overpressure Protection Monitoring is overpressure control by containment. When the working pressure reducing valve ceases to control the pressure, a second regulator installed in series, which has been sensing the downstream pressure, goes into operation to maintain the downstream pressure at a slightly higher than normal pressure.
BaCKpressure regulators/relieF valves Relief Valve for Liquid Service Type 98H – is a direct-operated relief valve for use on relief and backpressure applications involving large LP-Gas pumping systems and vaporizers. Internal pressure registration eliminates the need for a control line. Body materials are available in Gray Cast Iron, Steel or Stainless Steel. Temperature ratings are -40 to 180°F / -40 to 82°C for CI and SST and -20 to 180°F / -29 to 82°C for Steel.
regulator aCCessories Vent Assemblies TYPE Y602-1 (UMBRELLA TYPE) TYPE Y602-13 (ANGLE TYPE) Attached directly to the regulator vent connection to a regulator vent line, vent assemblies should be pointed downward on outdoor installations to avoid moisture build-up in the regulator spring case. Units with stabilizer assembly are intended for regulators with stability problems. The stabilizer gives a restricted breathing rate under normal conditions, opening for rapid discharge when necessary.
regulator aCCessories TYPE P499 TYPE P500 Adaptor With Screen (Type P499) Used to convert a 1/4-inch NPT inlet on regulators such as Types 912 and 67C to an inverted flare. TYPE P100A Type P500 Plug TYPE P100C Keeps dirt and foreign material from entering changeover assemblies. 1/4-inch Inverted Flare. Mounting Brackets Mounting brackets are used to mount regulators securely to the container or to the side of the building.
Internal Valves jet bleed 1 VALVE CLOSE Jet bleed equalization Valve open flow Limited bleed 2 jet bleed JET BLEED EQUALIZATION flow 3 flow limited bleed VALVE OPEN 4 limited bleed LIMITED BLEED 1. Because of the integral back check function of these valves, selective filling of manifold storage tanks requires the use of additional shutoff valves. Fisher® brand internal valves have gained wide field acceptance for use as primary shutoff valves, excess flow valves and back check valves(1).
threaded Internal ValVes C407 SERIES C471 SERIES C477 SERIES C486 SERIES Threaded Internal Valves Regulator Technologies offers the widest variety of threaded internal valves in the industry. While their most frequent use is in the liquid and vapor openings of bobtail and transport trucks, the valves can also be used in stationary storage tanks, complying with NFPA 58 requirements. Designed as primary shutoff valves, the units are designed with several features that help control product discharge.
sPeCIal serVICe threaded Internal ValVes C871 SERIES C886 SERIES C877 SERIES C807S-10 SERIES C807-10 SERIES C897 SERIES C800 Series Threaded Internal Valves Specifications The Fisher C800 Series Internal Valves provide the same primary shutoff and excess flow protection as the C400 Series, but are offered in a wide variety of body materials and elastomeric seals. With industrial process installations spanning the globe, the C800 Series has been the trusted product line for decades.
Threaded Internal Valves “Top of tank” position “Bottom of tank” position “Horizontal” position Internal valve tank positions x In-Line Adaptors Z D Y Z In-line adaptor 48 Dimensions, Inch / mm X Y D 1-1/4-inch FNPT 4.70 / 119 2.75 / 70 2.05 / 52 2-inch FNPT 6.77 / 172 3.5 / 89 2.80 / 71 3-inch FNPT 7.53 / 191 4.5 / 114 3.
Threaded Internal Valves Threaded Valve Specifications ! Pressure Rating: 400 psig / 27.
Threaded Internal Valves 20 / 20 1.4 20 18 18/ 1.
Threaded Internal Valves B-MNPT c Closed D b-mnpt d Approximate top of boss or coupling C Approximate top Of boss or coupling 1/4 inch e E A - FNPT A - FNPT 70° SWING 70° SWING c407-10 and C807-10 Series c477, C877 and C897 series b d APPROXIMATE TOP OF BOSS OR COUPLING C CLOSED a e H 1/4 INCH FNPT a F C471 and C871 SERIES 70° SWING Threaded Valves Type Number A, INCH (FNPT) B, INCH (MNPT) Dimensions, Inch / mm C D E F H Installation Clearance Diameter, Inch / mm C407-10 1.
Flanged Internal ValVes TYPE C483-24 TYPE C484-24 Flanged Internal Valves 3-inch / DN 80 Flanged Sizes Flanged valves provide a sturdy and compact means of directly mounting a pump or piping connection. Special stud bolts, weakened with a groove on the outside diameter, are furnished with the valves to permit the pump or piping to shear off in the event of an accident, leaving the valve intact.
Flanged Internal Valves Flanged Valve Specifications DO NOT USE the excess flow function incorporated into Fisher® C Series internal valves or F Series excess flow valves to satisfy the passive shutdown requirement in 49CFR§173.315(n)(2). DO NOT include the excess flow incorporated into Fisher C Series internal valves or F Series excess flow valves in a DCE certification under 49CFR§173.315(n)(2).
Flanged Internal ValVes TYPE C404-32 TYPE C404M32 wITH P313 HANDLE ASSEMBLY TYPE C404A32 wITH P614A ACTUATOR 4-inch / DN 100 Flanged Size (Stainless Steel Construction) The Type C404-32 is the only internal valve that cannot be opened and closed by the Type P650 cable control (refer to page 60). Type C404-32 – Used widely on transport trucks and large storage tanks, the 4-inch / DN 100 flanged unit comes standard with all stainless steel construction for maximum protection against rust and corrosion.
sPeCIal serVICe Flanged Internal ValVes TYPE C884-24 TYPE C891 TYPE C883-24 TYPE C804A-32 TYPE C804-32 TYPE C804M-32 C800 Series Flanged Internal Valves Specifications The Fisher® C800 Series Flanged Internal Valves provide the same primary shutoff and excess flow protection as the C400 Series, but are offered in a wide variety elastomeric seals. With industrial process installations spanning the globe, the robust flanged C800 Series has been the trusted product line for decades.
Flanged Internal Valves C B D A E 6” STUD (8 Required In-Line Piping Dimensions, Inch / mm A ASME CL300 RF Flange outlet B C D E Pipe Size Reducer Minimum ASME CL300 RF Flange 3 inches / DN 80 6 / 152 6 x 3 / 152 x 76 7.9 / 201 3 inches / DN 80 4 inches / DN 100 8 / 203 8 x 4 / 203 x 102 11.5 / 292 4 inches / DN 100 Studding Outlet O.D. And THICKNESS TO SUIT CONTAINER SPECIFICATIONS 45° C D MAX. 1 / 25 MIN.
Flanged Internal Valves 3-INCH / DN 80 CL300 ASME RF FLANGE MODIFIED [4.62 / 117 DIAMETER BORE and 5.75 / 148 mm RF] A 3-INCH / DN 80 CL300 ASME RF FLANGE MODIFIED [4.62 / 117 diameter BORE and 5.75 / 148 mm RF] A B B 70° SWING 70° SWING Types c484-24 and C884-42 Types c483-24 and C883-24 4-INCH / DN 100 CL300 ASME RF FLANGE MODIFIED [5.88 / 149 Diameter BORE and 7.00 mm RF] A 1.56 / 39.
Internal Valve Controls Air Interlock Systems An air interlock system can be configured for transport and bobtail trucks with air brakes by using air cylinder actuated internal valves. This system simultaneously interlocks the internal operation with the truck air brakes without affecting normal air brake operation. It complies with DOT MC331 and NFPA 58 requirements regarding thermal and remote release feasibility.
Internal ValVe aCCessorIes TYPE P650 TYPE P341 TYPE P315 TYPE P313 TYPE P340 Cable Controls Latch/Remote Release Mechanisms Fisher brand cable controls and accessories can be furnished to remotely open and close all internal valves except the 4-inch / DN 100 flanged size. This equipment can be used to comply with NFPA 58 and DOT requirements for MC331 cargo tanks.
Internal ValVe aCCessorIes TYPE P389 TYPE P731 TYPE P613 TYPE P713 TYPE P623 TYPE P639a TYPE P723 TYPE P739 TYPE P614A TYPE P714 NOTE: INTERNal ValVES ShOwN aRE NOT INClUDED. P Series Pneumatic Actuators All Fisher® brand internal valves can be ordered with a pneumatic actuators that permits the valve to be opened and closed from a remote location.
emergenCy shutoFF ValVes TYPE N550 (VALVE CLOSED) TYPE N550 wITH TYPE P327D TYPE N550 wITh TYPE P539a Snappy JoeTM Emergency Shutoff Valves for Bulk Plants Snappy Joe Type N550 emergency Shutoff Valves (eSVs) are designed for in-line installations, usually near a bulkhead. The valves provide a means of shutting off gas in the event of a hose rupture or piping break at the transfer area to avoid a large scale loss of LP-Gas or Anhydrous Ammonia (NH3).
Emergency Shutoff Valves Emergency Shutoff Valves Flow In GPM / l/min Propane Type Number Body Size, inch Accessories 1 psid / 69 mbar d 2 psid / 0.14 bar d N550-10 1-1/4 FNPT 110 / 416 150 / 568 N550-16 2 FNPT 190 / 719 295 / 1117 N550-24 3 FNPT 580 / 2195 850 / 3127 Type P164B Cable Release Type P327D Pneumatic Release Type P539A Pneumatic Actuator Type N550 capacity curve VALVE DIFFERENTIAL PRESSURE, psid / bar d 25 / 1.72 20 / 1.38 15 / 1.03 10 / 0.69 5/ 0.
emergenCy shutoFF ValVes QUICk DISCONNECT NIPPLE EXCESS FLOw SPRING MAIN POPPET INTERNAL THREAD NIPPLE HARDENED STAINLESS STEEL PIPE THREADS wRENCHING HEX FUSE PLUG SEAT DISC PILOT VALVE PISTON TYPE N562 Snappy JoeTM Emergency Shutoff Valves for Railroad Tank Cars Hardened Threads – The 2-inch FNPT threads on the nipple portion are of hardened stainless steel to reduce wear from repeated use.
eXCess FloW ValVes TYPE F138 F100 SERIES TYPE F134 TYPE F130 excess flow check valves are intended to close upon excessive discharge of vapor or liquid resulting from a break in the hose or piping system. They are used to protect cylinder, tank and piping systems and are available in a large variety of sizes and body configurations. Standard temperature rating is -20 to 160°F / -29 to 71°C. When flow exceeds the valve’s setting, the valve closes and remains closed until the system equalizes.
Internal relIeF ValVes TYPE H722 TYPE H733F3 TYPE H733 Flush Mounted Internal Relief Valves Tight fitting protective caps (Types P297 and P298) are standard on the valve to ensure no debris blocks the valve discharge. Standard setpoints listed with UL® for the Type H722 include 125, 156, 250, 265, 275 and 312 psig / 8.6, 10.8, 17.2, 18.3, 19.0 and 21.5 bar. Standard set points listed with UL for the Type H733 include 250 and 265 psig / 17.2 and 18.3 bar. All set points between 100 and 400 psig / 6.
Internal relIeF ValVes TYPE H284 TYPE H5114 TYPE P104-24 Large Relief Valves and all other parts are inside the tank, safe from tampering. FieldRepairable valve seats allow for seat replacement without affecting relief setpoint. Standard setpoints listed with UL® for the Type H284 includes 225 and 250 psig / 15.5 and 17.2 bar. Standard setpoints listed with UL for the H5114 includes 250 and 265 psig / 17.2 and 18.3 bar. All set points between 100 and 400 psig / 6.9 and 27.
BulK Plant relIeF ValVes TYPE 63EGLP 63EGLP SERIES UL® LISTED FOR LP-GAS 63EGLP Series Relief Valves relief technologies. The accuracy and repeatability of pilot-operated pressure regulation excercises precise control during relief situations without relying on last-generation pop-style relief mechanics. The Fisher Type 63eGLP is the evolutionary leap forward in bulk plant pressure relief combining safety, durability and serviceability into one superior package.
eXternal relIeF ValVes TYPE P206 TYPE H100 External Relief Valves TYPE P174 TYPE H185 The external relief valves use Brass as material of construction. Standard product temperature rating is -20 to 160°F / -29 to 71°C. Used on ASMe and DOT containers, all working parts of these valves are outside the container connection so they must be protected against mechanical damage. Protective caps are shipped with Fisher® brand external relief valves. Replacement caps may be ordered separately (refer below).
gloBe and angle ValVes TYPE N310 GLOBE VALVE TYPE N310-24 GLOBE VALVE TYPE N410-24 ANGLE VALVE Globe and angle valves are widely used at bulk plants to control gas flow in the piping system, at storage tanks, on trucks and at pumps or compressors. Their body configuration permits installation in a straight section of pipe (globe body) or where it is desired to make a change in piping direction (angle body). All units have a 1/4-inch FNPT plugged boss in the downstream side of the body.
BaCK CheCK ValVes Back check valves allow flow in only one direction and are normally closed. They are installed in liquid filling connections on stationary storage tanks, bobtail delivery trucks and liquid transfer lines. G100 Series G100 Series – used mainly in tank inlet connections, are offered in two styles of seat construction: metal-to-metal or soft seat. The soft seated construction is for the filling connection on bobtail delivery trucks.
hose end, FIller and lIQuId transFer ValVes Hose End Valves Type N480 – hose end valves are intended for quick opening and closing during bobtail truck deliveries of LP-Gas or Anhydrous Ammonia (NH3). The unique design prevents opening unless attached to a 1-3/4-inch ACMe filler valve at the tank. The 45° angle body configuration with 1-inch NPT inlet gives maximum handling ease during the transfer operation. Standard product temperature rating is -20 to 160°F / -29 to 71°C.
ByPass and BaCKPressure ValVes Bypass Valves for Large Pumps Designed for bypass on 2 to 4-inch size pumps, the N100 Series is widely used on both LP-Gas and Anhydrous Ammonia (NH3) applications. The throttling action of the N100 Series allows only surplus pump discharge to be returned to the tank. A venturi flow passage gives a boost effect, permitting a greater valve opening for increased flow at the lower pressure build-ups when bypassing full pump output.
ByPass and BaCKPressure ValVes Bypass Valves for Small Pumps N110 Series – is intended for bypass service on the smaller pumps (5 to 40 GPM / 18.9 to 151 l/min) used on stationary tanks or delivery trucks. Suitable for LP-Gas or Anhydrous Ammonia (NH3) installations, the valve has an internal sensing orifice and does not require an external sensing line. Standard product temperature rating is -20 to 160°F / -29 to 71°C.
LIQUID LEVEL INDICATORS TYPE J415-1 J31 SERIES TYPE J415 Liquid Level Vent Valves Rotary Gauges Fisher® brand rotary gauges can be used on stationary or mobile tanks to visually indicate the amount of LP-Gas or Anhydrous Ammonia (NH3) in the container. They are also used in filling the tank to the proper liquid level. On mobile applications and some large stationary storage tanks, hangers are recommended to support the horizontal length of the dip tube.
COUPLINGS AND ADAPTORS TYPE M390 1 2 3 4 Type M390 POL Filler Coupling Female ACME Filler Couplings These couplings allow connection of ACME threads to NPT. One side is 1-1/4 through 4-1/4-inch female ACME. The other side is 3/8 through 3-inch NPT. Available in brass or steel. Standard product temperature rating is -20 to 160°F / -29 to 71°C.
COUPLINGS AND ADAPTORS 2 3 TYPE M570 Single-Piece POL Adaptors Filler Hose Adaptor These single-piece brass POL adaptors are available in four styles. Connections are 1/4 through 3/4-inch NPT, 3/8-inch flare and 1/2-inch NPT flare. Brass construction. Standard product temperature rating is -20 to 160°F / -29 to 71°C. Intended for the outlet of a bobtail truck filling hose, the Type M570 enables the filling hose to be removed if the filler valve fails to close.
COUPLINGS AND ADAPTORS TYPE M229 TYPE M219 TYPE M431 TYPE M432 TYPE M108 OR M109 Female ACME Caps ACME caps of various sizes and materials are used on male ACME threads to keep debris out of the piping systems. Small sizes are designed for hand tightening. Standard product temperature rating is -20 to 160°F / -29 to 71°C. Larger sizes are intended to be either tightened by hand or with the use of the Type P120B spanner wrench.
MISCELLANEOUS EQUIPMENT Clamp Hose Couplings Type M3162 – Clamp Hose Couplings, for use on LP-Gas or Anhydrous Ammonia (NH3), are designed to be compact yet rugged for long, dependable service. A small boss on the clamp portion of the coupling keeps the bolt from turning when installing, making installation much easier. Each ductile iron unit receives a coat of electro deposition paint. Larger size clamp hose couplings can be furnished with a swivel nut female ACME outlet that reduces weight and space.
MISCELLANEOUS EQUIPMENT TYPE P120B TYPE P520L Spanner Wrench Adjustable Orifice Reamer Used to tighten and loosen large female ACME caps and couplings in the 2-1/4, 3-1/4 and 4-1/4-inch sizes. Use Type P520L to enlarge orifices on LP-Gas appliances ranging from drill size no. 80 to 50.
80
Technical References Conversion Factors SI Conversion Factors ASME Conversion Factors Multiply By To Obtain Multiply Length and Area Length and Area Millimeters 0.0394 Inches Meters 3.2808 Feet Sq. Centimeters 0.155 Sq. Inches Sq. Meters 10.764 Sq. Feet Inches Feet Sq. Inches Sq. Feet Volume and Mass Volume and Mass Cubic Meters 35.315 Cubic Feet Liters 0.0353 Cubic Feet Gallons 0.1337 Cubic Feet Cubic cm. 0.061 Cubic Inches Liters 2.
additional configurations REGULATORS, RELIEF VALVES, AND FITTINGS Commercial/Industrial High-Pressure Regulators Type No. 1301F-1 Configuration Type No. 1/4-inch FNPT Brass, HP Reg, 10 to 75 psi / 0.69 to 5.2 bar 1301F-2 1/4-inch FNPT Brass, HP Reg, 50 to 150 psi / 3.4 to 10.3 bar 1301F-3 1/4-inch FNPT Brass, HP Reg, 100 to 225 psi / 6.9 to 15.5 bar 1301G-101 1/4-inch FNPT Brass, HP Reg, 200 to 500 psi / 13.8 to 34.5 bar 627-117 1-inch FNPT DI, HP Reg with DI Casing, 3/8-inch port, 15 to 40 psi / 1.
additional configurations REGULATORS, RELIEF VALVES, AND FITTINGS Commercial/Industrial High-Pressure Regulators (continued) Type No. Configuration Type No. 627R-116 3/4-inch FNPT DI, HP Reg with Relief, 3/8-inch port, 70 to 150 psi / 4.8 to 10.3 bar 627R-118 3/4-inch FNPT DI, HP Reg with Relief, 1/2-inch port, 15 to 40 psi / 1.0 to 2.8 bar 627R-119 3/4-inch FNPT DI, HP Reg with Relief, 1/2-inch port, 35 to 80 psi / 2.4 to 5.
additional configurations REGULATORS, RELIEF VALVES, AND FITTINGS Commercial/Industrial High-Pressure Regulators (continued) Type No. Configuration 630-326 2-inch FNPT CI, HP Reg, 1/2-inch port, 46 to 95 psi / 3.2 to 6.6 bar 630-327 2-inch FNPT CI, HP Reg, 1/2-inch port, 90 to 150 psi / 6.2 to 10.3 bar 630-328 2-inch FNPT CI, HP Reg, 1/2-inch port, 150 to 200 psi / 10.3 to 13.8 bar 630-329 2-inch FNPT CI, HP Reg, 1/2-inch port, 200 to 275 psi / 13.8 to 19.
additional configurations REGULATORS, RELIEF VALVES, AND FITTINGS Commercial/Industrial Low-Pressure Regulators Type No. Configuration 133H-2 2-inch FNPT CI, HP Reg, 2 to 5 psi / 0.14 to 0.34 bar 133H-4 2-inch CL125 FF CI, HP Reg, 1.5 to 3 psi / 0.10 to 0.21 bar 133H-5 2-inch CL125 FF CI, HP Reg, 2 to 5 psi / 0.14 to 0.34 bar 133H-6 2-inch CL125 FF CI, HP Reg, 5 to 10 psi / 0.34 to 0.69 bar 133HP-AC1 2-inch FNPT CI, Dist. Serv. Self Op Reg, 6 to 20 psi / 0.41 to 1.
additional configurations REGULATORS, RELIEF VALVES, AND FITTINGS Liquid Regulators Type No. Configuration Type No. 627W-13 3/4-inch FNPT WCC, HP Liquid Reg, 1/2-inch port, 10 to 20 psi / 0.69 to 1.4 bar 627W-14 3/4-inch FNPT WCC, HP Liquid Reg, 1/2-inch port, 15 to 40 psi / 1.0 to 2.8 bar 627W-15 3/4-inch FNPT WCC, HP Liquid Reg, 1/2-inch port, 35 to 80 psi / 2.4 to 5.5 bar 627W-16 3/4-inch FNPT WCC, HP Liquid Reg, 1/2-inch port, 70 to 150 psi / 4.8 to 10.
additional configurations REGULATORS, RELIEF VALVES, AND FITTINGS Liquid Regulators (continued) Type No. Configuration 95H-21 3/4-inch FNPT WCB, Reg, 70 to 150 psi / 4.8 to 10.3 bar, Trim 3A 95H-22 1-inch FNPT WCB, Reg, 15 to 30 psi / 1.0 to 2.1 bar, Trim 3A 95H-23 1-inch FNPT WCB, Reg, 25 to 75 psi / 1.7 to 5.2 bar, Trim 3A 95H-24 1-inch FNPT WCB, Reg, 70 to 150 psi / 4.8 to 10.3 bar, Trim 3A 95H-3 1/4-inch FNPT CI, Reg, 70 to 150 psi / 4.8 to 10.
additional configurations REGULATORS, RELIEF VALVES, AND FITTINGS Relief Valves Type No. Configuration Type No. 1805-15 3/4-inch FNPT CI, Relief Valve with Brass cap, 5 to 35 psi / 0.34 to 2.4 bar 1805-16 3/4-inch FNPT CI, Relief Valve with Brass cap, 10 to 60 psi / 0.69 to 4.1 bar 1805-17 3/4-inch FNPT CI, Relief Valve with Brass cap, 20 to 125 psi / 1.4 to 8.6 bar 1805-19P 1-inch FNPT CI, Relief Valve with Brass cap, 10 to 60 psi / 0.69 to 4.
additional configurations REGULATORS, RELIEF VALVES, AND FITTINGS Relief Valves (continued) Type No. Configuration Type No. 98H-3 1/4-inch FNPT CI, Relief Valve/Backpressure Reg, 70 to 140 psi / 4.8 to 9.7 bar, Trim 3 98H-31 1-inch FNPT CI, Relief Valve/Backpressure Reg, 130 to 200 psi / 9.0 to 13.8 bar, Trim 3 98H-32 1-inch FNPT CI, Relief Valve/Backpressure Reg, 15 to 35 psi / 1.0 to 2.4 bar, Trim 4 98H-33 1-inch FNPT CI, Relief Valve/Backpressure Reg, 25 to 75 psi / 1.7 to 5.
additional configurations REGULATORS, RELIEF VALVES, AND FITTINGS Relief Valves (continued) Type No. Configuration 98H-91 2-inch FNPT WCB, Relief Valve/Backpressure Reg, 20 to 65 psi / 1.4 to 4.5 bar, Trim 4 98H-96 1-1/2-inch FNPT CI, Relief Valve/Backpressure Reg, 50 to 100 psi / 3.4 to 6.9 bar, Trim 3 98H-97 1-1/2-inch FNPT CI, Relief Valve/Backpressure Reg, 50 to 100 psi / 3.4 to 6.9 bar, Trim 4 98H-98 1-1/2-inch FNPT WCB, Relief Valve/Backpressure Reg, 50 to 100 psi / 3.4 to 6.
additional configurations REPAIR KITS AND PILOTS Regulator Repair Kits Repair Kits for Internal Valves Type No. Type No.
additional configurations REPAIR KITS AND PILOTS Relief Valve Repair Kits Type No. Configuration RH282732T12 RH722T00012 Repair Kit for Type H732 Repair Kit for Type H722 Globe and Angle Valve Repair Kits Type No.
Index INDEX Series / Type No. Page No. 50-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 50P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 64SR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 67CD. . . . . . . . . . . . . . . . . . . . . . . .
United States Asia Mexico Outside U.S. Europe LP-Gas Equipment Distributors Emerson sales, service and technical support are close at hand. Anywhere in the world, Emerson resources are available by telephone or on our website. Our distribution network includes an experienced sales and support team, with more than 2,000 technical experts available from nearly 200 offices throughout the world. Please visit our website to find the LP-Gas Equipment Distributor near you. www.fisherregulators.