User`s guide

INDEX
Printed in U.S.A.
ASCO Power Technologies, L.P. 2007
In the United States, for service call ASI at 1–800–800–2726 (ASCO).
In Canada, for service call at 1–888–234–2726 (ASCO).
Copyright
A
address, 2–8, 2–9
arrow push–buttons, 1–1
B
baud rate, 2–8, 2–9
C
change password, 2–8, 2–9
clear log, 2–8, 2–9
closed–transition transfer, 4–3
commit to transfer, 2–6, 2–7
communication, 2–8, 2–9
control overview, 1–1
cover removal, A–1
CP settings, see settings
D
date setting, 2–10, 2–11
daylight saving time, 2–11
Decrease Value push–button, 1–1
default settings, 2–2, 2–4, 2–6, 2–8,
2–10
reset, 2–9
delayed–transi tion transfer, 4–6
description of operation
closed–transition, 4–3
delayed–tra nsition, 4–6
open–transition, 4–1
DIP switch a ctuators
data i nput/password lock, A–3
frequency of sources, A–3
nominal input voltage, A–2
phases of sources, A–3
transfer switch type, A–2
E
engine exerciser, 1–2, 2–10, 2–11
engine cooldown, 2–10, 2–11, 4–2
Enter/Save Settings push–button, 1–1
Esc (escape) push–button, 1–1
event logging, 2–8, 2–9, 2–12
F
failuretosynchronize
auto bypass, 2–6
time delay, 2–4, 2–5, 4–4
Features
1C, 2–4, 2–5, 4–1
1F, 2–4, 2–5
2B, 2–4, 2–5, 4–1
2E, 2–4, 2–5, 4–2
3A, 2–4, 2–5, 4–2
5, 2–7, 2–14, 4–1
6B, 2–14
6C, 2–14
6Z, 2–14
11C, 2–10, 2–11, 4–1
27, 2–6, 2–7, 4–1, 4–2
31F, 2–4, 2–5, 4–1
31M, 2–4, 2–5, 4–1
31G, 2–4, 2–5
31N, 2–4, 2–5
34A, 2–14
34B, 2–14
72A, 2–9, 2–13, 4–1
frequency settings, 2–2, 2–3, A–3
G
general settings, 1–2, 2–8, 2–9
H
HELP, for service, call
1–800–800–2726 in the US
1–888–234–2726 in Canada
customercare@asco.com
I
Increase Value push–button, 1–1
inphase monitor, 2–6, 2–7
K
Keypad Locked setting, 2–8, 2–9
L
language, 2–8, 2–9
load shed, 2–6, 2–7
logging, event, 2–8, 2–9
M
Menu Scroll push–buttons, 1–1
O
open–transiti on transfer, 4–1
P
password, ente r, wrong, 2–1
change, 2–8, 2–9
forgotten, A–3
lock, A–3
phase rotation monitor, 2–6, 2–7
phases, A–3
print enable, 2–8, 2–9
S
seria l communication, 2–8, 2–9
service, 2–13, 2–14
settings
CP, 2–3
engine exerciser, 1–2, 2–10, 2–11
feat ures, 1–2, 2–6, 2–7
general, 1–2, 2–8, 2–9
overview, 1–2
time & date, 2–10, 2–11
time delay, 1–2, 2–4, 2–5
shed load, 2–6, 2–7
T
test mode, 4–1
time delays
1C, 2–4, 2–5, 4–1
1F, 2–4, 2–5
2B, 2–4, 2–5, 4–1
2E, 2–4, 2–5, 4–2
3A, 2–4, 2–5, 4–2
11C, 2–10, 2–11, 4–1
27, 2–6, 2–7, 4–1, 4–2
31F, 2–4, 2–5, 4–1
31M, 2–4, 2–5, 4–1
31G, 2–4, 2–5
31N, 2–4, 2–5
CT delayed transfer, 2–6, 2–7
inphase monitor, 2–6, 2–7
time setting, 2–10, 2–11
tranfer switch type, A–2
U
unbalance, voltage, 2–2, 2–3
V
view event log, 2–12
voltage DIP switch actuators, A–2
voltage jumper blocks, A–4
voltage settings, 2–2, 2–3
Y
Y–Y primary failure detect, 2–6, 2–8