user manual

MITX-430/MITX-440-DVI-2E Installation and Use Guide (6806800K37B)
Safety Notes
112
z Install the system safely. Make sure that cables and cords are out of the way.
z Make sure that the set-up is comfortable for users.
Product Damage
Using wire sizes that are not sufficient for your environment may result in cable damage.
Always check with your local building authorities for wire sizing requirements for your
environment and make sure that the installation complies with the 1993 National Electric
Code (NEC) and other applicable codes.
Make sure to connect the ground wire to a reliable earth ground connection to comply with
Class 1 Equipment requirements.
Damage of the Product and Additional Devices and Modules
Incorrect installation or removal of additional devices or modules damages the product or the
additional devices or modules.
Before installing or removing additional devices or modules, read the respective
documentation and use appropriate tools.
System Damage
Attaching power inputs to non-TNV/SELV approved power sources causes the system to fail
compliance with safety regulations.
Make sure to attach power inputs to approved Telephone Network Voltage (TNV) or Safety
Extra Low Voltage (SELV) branch circuits only.
Personal Injury or Product Damage
The product is supplied by a TNV-2 voltage. This voltage is considered hazardous. Make sure
that the external power supply meets the relevant safety standards.
Make sure that TNV-2 is separated from dangerous voltages (mains) through double or
reinforced insulation.