Table 2-2 MVME7100 Specifications
Characteristics Operating Nonoperating
Operating temperature 0°C to +55°C (32°F to 131°F) entry
air with forced-air cooling
–40°C to +85° C (-40°F to 185°F)
Temperature change +/-0.5° C/min according to NEBS
Standard GR-63-CORE
Relative humidity 5% to 90% noncondensing 5% to 90% noncondesning
Vibration 1 G sine sweep, 5-100 Hz,
horizontal and vertical (NEBS1)
Shock 20 G peak (half sine) 11mSec
Free Fall 100 mm (unpackaged) per GR-63-
CORE