Installation manual

60
Epsilon EP-B Base Drive Reference Manual
Resistance
The resistance value of the shunt.
Shunt Control Group
Shunt Power RMS
This parameter models the thermal heating and cooling of the drive internal shunt. This parameter indicates the percent
of shunt capacity utilization. When this value reaches 100 percent, the drive will generate an RMS Shunt Power Fault.
Bus Voltage
Displays the actual measured voltage on the DC power bus.
Teach View
The Teach view is used with Analog Position mode to setup the two points (min and max) needed
Figure 46: Teach View
Teach Min
Define Home
When this check box is selected, on the first teach pulse of the teach function the position command is loaded into the
Define Home Posn text box (located on the Setup view).
Set Analog In Position
Select this check box to load the position command value into the Analog Min Position parameter (on the Analog Inputs
view) on the first pulse of the teach function.
Set Analog In Voltage
Select this check box to load the current A/D value in the Analog Min Voltage parameter (on the Analog Inputs view) on
the first pulse of the teach function.
Set Analog Out Ch 1 Position
Select this check box to load the position command value in the Analog Min Value for Channel 1 (on the Analog Outputs
view) on the first pulse of the teach function.
Set Analog Out Ch 1 Voltage
Select this check box to load the position command value in the Analog Min Voltage for Channel 1 (on the Analog
Outputs view) on the first pulse of the teach function.