Installation manual

61
Setting Up Parameters
Set Analog Out Ch 2 Position
Select this check box to load the position command value in the Analog Min Value for Channel 2 (on the Analog Outputs
view) on the first pulse of the teach function.
Set Analog Out Ch 2 Voltage
Select this check box to load the position command value in the Analog Min Voltage for Channel 2 (on the Analog
Outputs view) on the first pulse of the teach function.
Set Position Limit
Select this check box to load the position command value in the Position Limit Min parameter (on the Analog Inputs view)
on the first pulse of the teach function.
Teach Max
Define Home
When this check box is selected, on the second teach pulse of the teach function the position command is loaded into
the Define Home Posn text box (located on the Setup view).
Set Analog In Position
Select this check box to load the position command value into the Analog Max Position parameter (on the Analog Inputs
view) on the second pulse of the teach function.
Set Analog In Voltage
Select this check box to load the current A/D value in the Analog Max Voltage parameter (on the Analog Inputs view) on
the second pulse of the teach function.
Set Analog Out Ch 1 Position
Select this check box to load the position command value in the Analog Max Value for Channel 1 (on the Analog Outputs
view) on the second pulse of the teach function.
Set Analog Out Ch 1 Voltage
Select this check box to load the position command value in the Analog Max Voltage for Channel 1 (on the Analog
Outputs view) on the second pulse of the teach function.
Set Analog Out Ch 2 Position
Select this check box to load the position command value in the Analog Max Value for Channel 2 (on the Analog Outputs
view) on the second pulse of the teach function.
Set Analog Out Ch 2 Voltage
Select this check box to load the position command value in the Analog Max Voltage for Channel 2 (on the Analog
Outputs view) on the second pulse of the teach function.
Set Position Limit
Select this check box to load the position command value in the Position Limit Max parameter (on the Analog Inputs
view) on the second pulse of the teach function.