Epsilon EP-B Base Drive Reference Manual
Attached Function
This displays the Input Function assigned each particular Input Line.
Configuration
The debounce value is displayed next to each input line, the active state for the attached input function is shown next to
the input function.
Input Lines Group
Debounce Text box
The debounce value is displayed next to each input line. This feature helps prevent false input triggering in noisy
electrical environments. Enter a “Debounce Time” in milliseconds. The value entered here is the minimum amount of
time the input line will need to be active before it is recognized as a valid input.
Figure 49: Input Line Diagram
Forced Off and Forced On Check Boxes
You can force an input line to a level by using the Forced On and Forced Off check boxes. When you force an input line
on or off, all the functions assigned to that line will be affected. This check box is only available to select when online
with the drive.
The forced state of the input and output lines are not saved to NVM and will reset to normal operation when the
drive is powered up or re-booted.
Output Lines View
This view is divided into two windows. The “Output Function” window, on the left side, displays the available output
functions. The “Output Line” window, on the right side, displays the output lines, the attached output function and the
line configuration (Active Off).
Input
Terminal
Input Lines
Force On/Off
Command
Input Lines
Force On/Off
Enable
Debounce
Timer
Input Line
Debounced
Status
Input Line
Status
Input Line
Raw Status