The +/- Limit faults are automatically cleared when the fault condition is removed. The table below lists all the fault codes
in priority order from highest to lowest. This means that if two faults are active, only the higher priority fault will be
displayed.
Display Fault Action to Reset Bridge Disabled
Flash Invalid Reprogram the Flash Yes
Drive Overtemp\
Allow Drive to Cool down,
Cycle Power or Cycle Logic
Power
Yes
Power Up Test
Cycle Power or Cycle Logic
Power
Yes
NVM Invalid Reset Button or Input Line Yes
Invalid Configuration Reset Button or Input Line Yes
Power Module
Reset Button or Input Line
Cycle Logic Power
Yes
High DC Bus Reset Button or Input Line Yes
Low DC Bus Reset Button or Input Line Yes
Encoder State
Cycle Power or Cycle Logic
Power
Yes
Encoder Hardware
Cycle Power or Cycle Logic
Power
Yes
Motor Overtemp
Allow Motor to cool down,
Reset Button or Input Line
Yes
RMS Shunt Power Reset Button or Input Line Yes
Overspeed Reset Button or Input Line Yes