Installation manual

8
Safety Information Product Overview Installation Diagnostics
Options and
Accessories
Specification
AC Line Filters
The AC line filters are necessary to comply with EMC emission and immunity standards. The drive was tested with
the filters presented in the table below and recommended by Control Techniques.
The following filters are a suitable alternative:
AC Line Filter Installation Notes
It is important to keep the filter inputs routed away from any electrical noise sources.
EMC criteria can be met in installations where multiple drives are supplied through a single filter, however, it is
the installers responsibility to verify EMC compliance.
Step 2: Mechanical Installation
The drive must be back mounted vertically on a metal mounting panel such as a NEMA enclosure, Additional space
is necessary above and below the drive for wiring and cable connections.
To allow sufficient air flow for cooling, leave at least 0.25" [6.3 mm] clear space on vented cover (left) side plus 0.50"
[12.7 mm] on heatsink (right) side. Leave additional space if cables are routed through this space.
Epsilon EP Part # Control Techniques Part # Rating
EP202, EP204
Schaffner FN2070-10/06 960307-01 10 A, 240 V, 1 Ø
Schaffner FS5278-16/08 960305-01
16 A, 240 V, 1 Ø
EP206 Schaffner FS5278-16/08 960305-01
EP209 Corcom 20EQ1 960308-01 20 A, 240 V, 1 Ø
EP216 Schaffner FN3258-16-44 960310-01 16 A, 480 V, 3 Ø
Epsilon EP Part # Control Techniques Part # Rating
EP202 Schaffner FN2070-6/06 6 A, 240 V, 1 Ø
EP202, EP204, EP206 Corcom 20EQ1 20 A, 240 V, 1 Ø
EP206 Schaffner FN2070M-16/08 16 A, 240 V, 1 Ø
EP209 Schaffner FN2070-25/08 25 A, 240 V, 1 Ø
EP216
Schaffner FN3270H-20-29 20 A, 480 V, 3 Ø
Schaffner FN258/16 960304-01 16 A, 480 V, 3 Ø
When drilling holes in mounting plate or trimming wires during installation of this or other equipment, do not
allow drill shavings or wire trimmings to enter the EP drive. Such foreign objects can compromise electrical
isolation creating a hazard or result in equipment failure.