Installation manual

Installation 19
Safety Information Product Overview Installation Diagnostics
Options and
Accessories
Specification
This inrush current specification assumes the drive has been powered off for at least 8 minutes at 40ºC (104ºF)
ambient or 5 minutes at 25ºC (77ºF) ambient. If this amount of time has not elapsed since power off, the inrush
current will be higher. Exception is the EP209 and EP216, they use active inrush limiting. Listed inrush current is
maximum.
AC Input Power Connections
Drive Model Input Voltage (Vac)
Frequency
(Hz)
Input Current (Amps RMS) at
Full Drive Output Current
Inrush Current
(Amps)
EP202
240 / 1 Ø
47 - 63
5.0 40 (5 ms)
EP204 8.5 65 (5 ms)
EP206 12.0 100 (5 ms)
EP209 16.0 34 (5 ms)
EP216
240 / 3 Ø or
240 / 1 Ø
16.0 34 (5 ms)
Power must be "Off" for a minimum of 6 minutes for the Epsilon EP206, EP209 and EP216 drives and 3
minutes for the Epsilon EP202 and EP204 drives before unplugging the power connection. This will ensure the
bus voltage has bled down to a safe level (below 50 Vdc).
Do not connect or disconnect AC power by inserting or removing the AC power connector. Using the
connector in this manner, even once, will damage the connector making it unusable.