NT and MG motors are equipped with up to three male MS (Military Standard) connectors, one for stator
connections, one for encoder connections and one for the brake (if so equipped).
Stator connections from the drive to the motor are made with the CMDS or CMMS cable have a female MS style
connector on the motor end and four individual wires and shield that connect to the motor power connector on the
front of the drive.
The motor ground wire and shields must be run all the way back to the drive terminal and must not be
connected to any other conductor, shield or ground except the enclosure wall for EMC.
Figure 24: Epsilon EP202-EP206 Drive - NT/MG Motor Power Wiring Diagram
NT or MG Motor
Power Connection
R
S
T
Ground
Connector Shell
Brown
Black
Blue
Green/Yellow
Shield
Important: PE ground
should connect to drive
and motor only. Nothing
should be connected
between these devices.
2" and 3" motor cable
connector (CMDS-xxx cable)
Wire crimp ferrules are recommanded:
For ground lead use -
Pheonix Contact p/n AI-TWIN 2X1, 5-8Bk/32 00 82 3
American Electrical/DigiKey 1381015/288-1130-ND
For motor leads use -
Pheonix Contact p/n AI 1,5-8 RD/32 01 13 6 or
ALTEC p/n H1.5/14 2204.0 Pk/100
Tighten screws to 5 in-lb.
EP204-I00-0000
9606XX-XX A1
SN 0610E014
Front View
24 Vdc
R
S
T
MOTOR
L1
L2
PE