user manual






A co-axial condenser provides ample capacity to han-
dle the heat rejection needs of the system while using
a minimum of liquid and low total pressure drop.

Head pressure operated regulating valves accurately
control the condensing temperature and maintain
system capacity for various entering liquid flow rates
and temperatures. Two-way valves with bypass are
standard.



Three-way valves provide accurate control of con-
densing temperature and thus maintain constant
system capacity while also keeping the condenser
water flow rate constant.

The high pressure option for the condenser circuit
consists of a regulating valve and a condenser rated
at 350 psig (2413 kPa) water-pressure. This option is
required in applications with large static head pres-
sures.

A compressor crankcase heater is available to pre-
vent the migration of refrigerant to the compressor
during off cycles.

The hot gas reheat assembly consists of a 3-way
directional solenoid operated valve and a hot gas
reclaim coil.



Factory charged and sealed, the water cooled con-
densing unit is ready to be installed quickly and eas-
ily. The counter-flow coaxial condenser with two-way
or three-way regulating valve designed for 150 psi
(1034.3 kPa) is matched to the heat rejection require-
ments of the compressor for a variety of flow rates
and fluid temperatures.
Condensing unit has a hot gas bypass standard fea-
ture that bypasses hot gas around the compressor
directly to the suction side of the compressor to pro-
vide capacity control and reduce compressor cycling.
System includes liquid injection valve to maintain
proper suction superheat.



The high pressure option for the condenser circuit
consists of a 2-way or 3-way water regulating valve
and condenser rated at 350 psig (2413 kPa) water
pressure. This option is required in applications with
large static heads.


Allows unit to be turned off for maintenance. Discon-
nect switch is available on indoor condensing units
only.

Consists of one pre-charged liquid line and one pre-
charged insulated suction line of soft copper tubing.
Each line has one male quick-connect coupling and
one female quick-connect coupling with an access
valve connection.
Available in 15 ft. (4.6m) and 30 ft. (9.1m) lengths for
interconnection of remote located condenser module.
Maximum recommended distance between evapora-
tor and condenser with pre-charged line sets is 45 ft.
(13.7m). For longer runs, use sweat adapter kit.

(3 ton only) - contains two suction and two liquid line
compatible fittings that allow field-supplied intercon-
necting refrigerant lines to be used.




The Liebert manufactured Fan Speed Control dry-
cooler is constructed of aluminum and features cop-
per tubes and aluminum fin design. It is low profile,
propeller fan type and provides quiet, trouble free
heat rejection. The drycooler features a variable
speed fan motor and a specially engineered solid
state fan speed transducer. The transducer senses
the temperature of the leaving glycol and modulates
the speed of the fan to maintain proper glycol tem-
peratures. An integral, factory-wired and tested con-
trol panel reduces installation time.

The glycol system includes a matching centrifugal
glycol pump. It is mounted in a vented, weatherproof
enclosure.
Optional Equipment—See page 13.
DISCONTINUED
PRODUC T