Data Sheet

www.Fisher.com
ValveLinkt Software Signature Series
Performance Testing
ValveLink Software Signature Series factory-executed
performance testing is available for any Fisherr control
valve assembly that includes a FIELDVUE
t
digital valve
controller.
Signature Series performance testing creates a
benchmark of an assembled valve's performance just
prior to shipment. This benchmark provides a starting
point for future data comparison, enabling you to
track the operating condition of your control valve and
maximize valve performance.
When ordered with your FIELDVUE equipped control
valve, our factory uses the diagnostic capability of
ValveLink software to thoroughly test each valve
assembly.
Test Levels
Three levels of Signature Series tests are available, with
each level providing valuable diagnostic data. When
you order a Signature Series test, you will receive the
test results electronically from your Emerson Process
Management sales office.
Signature Series 1
Within the Signature Series 1 test level, you receive:
n Instrument Configuration
n Status Monitor (@50% travel)
n Valve Spec Sheet
n Valve Signature, as recorded from -5 to 105% input.
n Dynamic Error Band Curve, as recorded from
-5 to 105% input
n Drive Signal, as recorded from -5 to 105% input
W9363-3
Signature Series 2
In addition to Signature Series 1 information, you
receive:
n Performance Step Test
n Status Monitor (0, 25, 50, 75, 100% travel)
Signature Series 3
Series 3 testing provides user specified Series 1 and 2
tests and allows customization of end points or scan
times. This capability lets you tailor the testing to your
specific requirements or process needs.
Signature Series 3 with Dead Band
plus Hysteresis
Provides user specifications from Series 1, 2, 3, and
Dead Band plus Hysteresis estimation per dead band
specifications. Refer to Bulletin 62.1:ValveLink
Software(S3) (D103549X012), available from your
Emerson Process Management sales office, for details.