FM-3 Programming Module Reference Manual
Limit Distance Hit Index.#.LimitDistHit
This source is activated when the registration sensor is not found before the Limit Distance is
traveled. If the Registration Window is enabled the sensor must be activated inside the
window to be recognized.
Name Index.#.Name
The user can specify an Index name of up to 12 characters.
Enable PLS Index.#.PLSEnable
When Activated, this parameter enables the PLS (programmable limit switch) function for the
specified index. It can be controlled from index view check box or from a program.
PLS Off Point Index.#.PLSOffDist
This an incremental distance from the start of the index to the Index PLS off point. This is an
unsigned value and is relative only to starting position of this index. Index direction does not
affect this parameter. Index.#.PLSStatus will be active if the distance traveled from the start
of the index is greater than the Index.#.PLSOnDist and less than the Index.#.PLSOffDist.
PLS On Point Index.#.PLSOnDist
This an incremental distance from the start of the index to the Index PLS On Point. This is an
unsigned value and is relative only to starting position of this index. Index direction does not
affect this parameter. Index.#.PLSStatus will be active if the distance traveled from the start
of the index is greater than the Index.#.PLSOnDist and less than the Index.#.PLSOffDist.
PLS Status Index.#.PLSStatus
Controlled by the PLSOn and PLSOff Points, this is relative to the distance commanded since
the start of the index. Index.#.PLSStatus will be active if the distance traveled from the start
of the index is greater than the Index.#.PLSOnDist and less than the Index.#.PLSOffDist.
RegistrationOffset Index.#.RegistrationOffset
This parameter is the the Distance the motor will travel after a valid registration sensor or
analog limit value has been detected.
Registration Type Index.#.RegistrationType
This selects either sensor or analog as the registration mark for a registration index.