Installation manual

116
FM-3 Programming Module Reference Manual
Velocity Jog.#.Vel
This parameter specifies the velocity used for jogging with the Jog.PlusActivate and
Jog.MinusActivate destinations or the Jog.#.PlusInitiate and Jog.#.MinusInitiate inside a
program. The units for this parameter are specified in the User Units view.
Select Jog.Select0
This destination is used to select between the jogs. It is used along with the Jog.PlusActivate
and Jog.MinusActivate destinations. If the Jog.Select0 destination is not active then the Jog.0
setup parameters will be used for jogging. If the Jog.Select0 input function is active, the Jog.1
setup parameters will be used for jogging. If the Jog.Select destination is changed during
jogging motion the axis will ramp smoothly from the previously selected jog velocity to the
new jog velocity using the specified jog acceleration. This is level sensitive.
Minus Activate Jog.MinusActivate
This destination is used to initiate jogging motion in the negative direction using the jog
parameters of the jog selected by the Jog select input function. Jogging will continue as long
as the destination is active. The motor will decelerate to a stop when the destination is
deactivated. This is level sensitive.
Plus Activate Jog.PlusActivate
This destination is used to initiate jogging motion in the positive direction using the jog
parameters of the jog selected by the Jog select input function. Jogging will continue as long
as the destination is active. The motor will decelerate to a stop when the destination is
deactivated. This is level sensitive.
Stop Jog.Stop
This is used only in programs to halt jogging motion. Jogging motion is initiated in programs
using the Jog.#.MinusActivate or Jog..#.PlusActivate instructions, and using the Jog.Stop
will cause the motor to decelerate to a stop at the Jog.#.Decel rate for the jog that is active.
Line Voltage LineVoltage
This parameter is used to calculate critical internal gains. There are two possible value: 115
or 230 VAC. A value of 115 VAC should not be used if the actual line voltage is 230,
otherwise damage to the E Series drive may result. The default value is 230 VAC.
BaudRate Modbus.BaudRate
Modbus baudrate for this FM module and drive.