Foundation IT PROTECTION SYSTEM
Too Much Equipment, Too Little Protection While sensitive electronics have changed over the past years, one thing remains constant — excessive heat, poor power quality and unauthorized access can damage or impair the operation of vital systems and peripherals. The answer lies in finding the correct enclosure system to house critical components for both small and large facilities.
The Solution That Gives You Exactly The Right Aumont Of Protection And Support Foundation stands out as the solution in three key areas: Adaptive Foundation’s highly flexible design accommodates varied support installation and application requirements. It is designed to provide easy access for equipment changes and relocation. Comprehensive Foundation features Liebert’s full line of computer-grade support systems, including environmental, power, monitoring and security.
The Answer No Matter What Your Needs The Foundation integration system is more than” just a rack”— it is the “foundation” of a mini-computer room. It is designed to deliver maximum flexibility today and to comprehensively accommodate future support needs in the rapidly changing network equipment environment. It can start simply as a basic integration system to house and organize network components.
Enclosure System The heavy duty Foundation frame is 12-gauge steel construction. It can accomodate shelf or rack mounted equipment on either 19 or 23 inch rails. The front and rear vertical frame members incorporate internal mounting rail options and provide space to route and manage cabling. Cable Access Provides entrance points for cable feeds to enclosure: Top, bottom and side to side.
Total Protection Under One Roof The Foundation MCR (Mini Computer Room) provides the peace-of-mind that comes from knowing that Liebert’s expertise and experience are protecting your vital network equipment and the integrity of your data. Based on the industry award winning Little Glass House design, the Foundation MCR self-contained integration system brings together all of the elements necessary to ensure the long-term viability of network components or other critical electronics.
Mini Computer Room Liebert SiteNet Integrator Sealed doors specially designed rubber gasket provides NEMA12 sealing protection. Secure door BCM (back-up Cooling Module) An external keybord tray option provides access to secured equipment without interrupting the internal conditions. Secure door- lockable door provides an extra measure of security by limiting access to critical equipment. A multi-point latch with key lock is provided.
Creating The Perfect Environment For Your Critical Systems Only Liebert can offers a real choice of computer-grade cooling options designed to meet your most demanding protection needs. For systems without ECM air conditioning, fan cooling provides enhanced heat removal. Either 1 or 2 “low noise” or “high ambient” fans can be factory installed - up to 5 fans can be installed in the field. Fans can be located either on top or back panel of the Foundation.
Environmental Panch are insulated on ECM supported system enhancing thermal and sound performance An optional top mounted ECM allows for maximum use of internal rack space and can be used to double capacity with internal/rack mount ECM. Sealed doors Provides entrance Points for cable Feeds to enclosure: Top, bottom and Side to side. BCM (Back-Up Cooling Module) provides cooling during a loss of utility power or high internal temperature conditions.
Power And Control For Continuous System Protection On-line UPS power protection — plus complete monitoring and communications capabilities - give your Foundation system the highest level of intelligent operation. Power protection and battery back-up State-of-the-art power protection is available in the Foundation integration system through the addition of a Liebert GXT 2U on-line uninterruptible power supply (UPS) system.
UPS & Monitoring System Door ajar sensor-option includes factory installed micro switches mounted on the front and rear doors of the Foundation enclosure to detect an open door. For use with the SiteNet Integrator. With the bundled Liebert SiteNet Integrator, your foundation system becomes an intelligent network node. It is capable of monitoring conditions such as temperature and humidity, as well as initiating user-defined actions when problems arise.
FOUN/E.