TECHNICAL DATA
FOUNDATION Enclosure
Part Number Description
HK7800000S-EU1 w19"h42U(1956)d750 rack mount enclosure / Plexiglas Front & Sheetmetal Rear Doors / Side Panels
HK7800000S-EU1S w19"h42U(1956)d750 rack mount enclosure / Plexiglas Front & Sheetmetal Rear Doors / No Side Panels
HK7880000S-EU1 w19"h42U(1956)d953 rack mount enclosure / Plexiglas Front & Sheetmetal Rear Doors / Side Panels
HK7880000S-EU1S w19"h42U(1956)d953 rack mount enclosure / Plexiglas Front & Sheetmetal Rear Doors / No Side Panels
HK7880000SPEU1 w19"h42U(1956)d953 rack mount enclosure / Perforated Front & Rear Doors / Side Panels
HK7880000SPEU1S w19"h42U(1956)d953 rack mount enclosure / Perforated Front & Rear Doors / No Side Panels
FOUNDATION MCR (Mini Computer Room)
Part Number Description
HD788CC00S-EU1 (w19"h42U(1956)d953 rack mount sealed enclosure, ECM2000LR, BCM2000L, No UPS)
HD7880000S-EU1 (w19"h42U(1956)d953 rack mount sealed enclosure, ECM Cluster Extension Duct, NO Side Panels)
ENCLOSURE DIMENSIONS
Model Overall Frame Dimensions Rack
Adjustable Rack Depth
Internal Rack Height
Height* Width** Depth*** Width Available Width B****
In. (mm) In. (mm) In. (mm) Max In. (mm) Rack U In. (mm)
H_780 77 (1956) 23.5 (597) 29.5 (750) 19 (483) 17.8 (450) 22.5 (571.5) 42 73.5 (1867)
H_788 77 (1956) 23.5 (597) 37.5 (953) 19 (483) 17.8 (450) 30.5 (775) 42 73.5 (1867)
*Casters add 1,5" to overall Height of Frame = 2000mm
** Side Panels add 0,75" each to overall width of frame
*** Doors add 0,25" each to overall depth of frame, BCM Option adds an additional 3" to overall depth of frame
**** Max Dimension is for ex-factory configuration. Rails can be inverted to provide an additional 4" of adjustment
Mounting Options
Enclosure/MCR
Fixed Shelf w19”d30”/38” Pullout Shelf d30"/38"
Fixed Rails Keyboard Tray Mounting Clipnuts and Screws
10 - 32 Thread M6 Thread
H_780 153018G1L 153009G1L 201193G1L 155942G1 201000G1 201000G2
H_788 153018G1L 153009G3L 201193G1L 155942G2 201000G1 201000G2
General Options
Enclosure/MCR Internal Light Sealed Entrance Cable Rings Cluster Kit Stabilisation Plate
2" hole 4" hole Vertical Horizontal
H_780, H_788 163527G3 201038G1L 201038G2L 201048G1L 201049P1 201033G1L 201067G1L
Monitoring Options
H_780, H_788 SITENET-EX230 LCM-IEC-10 163787G2L 163784G1L 168605G1L 163785G1L 163520G1L 163786G1L 163786G1L
All monitoring options can be field installed (including installation instructions and/or drawings/sketches as required)
*Alarm is powered by either the ECM or BCM - if neither ECM or BCM is available a Power Supply option must be selected
Cooling Options
Enclosure/MCR FAN Cooling Systems ECM Cooling System
FAN 1000 Low Noise 50Hz FAN 1000H High Ambient 50Hz FAN Block-off Assembly 50Hz ECM Heat Rejection Fan 50Hz
Top Mount ECM for 1000 VA UPS * Top Mount ECM for 1000 VA UPS *
HK780, HK788 163796G2L 163796G4L 201592G1L 163521P2 168124G6 168124G8
HD788 - - - 163521P2 168124G6 168124G9
*Requires Stabilizing Plate option (201067G1L)
PART NUMBERS AND CONFIGURATIONS LISTED ABOVE ARE AVAILABLE DIRECTLY FROM STOCK - MORE OPTIONS AND CONFIGURATIONS ARE ALSO AVAILABLE ON DEMAND, PLEASE REFER TO YOUR LIEBERT-HIROSS CONTACT
Enclosure/MCR
SiteNet Integrator
Load Control Module
(SiteNet
Interface Only)
Internal Temp/Humid
Opt. (SiteNet
Interface Only)
External
Temperature/Humid Opt.
(SiteNet Interface Only)
Door Ajar Sensor
Opt. ( SiteNet Interface)
High Temperature
Alarm*
Water
Detected Opt.*
Power Supply for
High Temp. & Water
Detect. Option
Smoke Detector Opt.
(requires High Temperature
Alarm Option)