Liebert® GXT4™ UPS 120V/208V 500VA-3000VA User Manual
TABLE OF CONTENTS IMPORTANT SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 GLOSSARY OF SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.0 PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.0 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 4.1 Startup Checklist for the Liebert GXT4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.2 Starting the UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.3 Manual Battery Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURES Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 Figure 33 Figure 34 Figure 35 Figure 36 Figure 37 Figure 38 Figure 39 Figure 40 Figure 41 Figure 42 Figure 43 Figure 44 Figure 45 Figure 46 Liebert GXT4 rack/tower models—front view . . . . .
TABLES Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 Table 12 Table 13 Table 14 Table 15 Table 16 Table 17 UPS models, power ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Input circuit breaker specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IMPORTANT SAFETY PRECAUTIONS ! WARNING Observe all cautions and warnings in this manual. Failure to do so may result in serious injury or death. Refer all UPS and battery service to properly trained and qualified service personnel. Do not attempt to service this product yourself. Opening or removing the cover may expose you to lethal voltages within this unit even when it is apparently not operating and the input wiring is disconnected from the electrical source. Never work alone.
The Liebert GXT4-3000RT208 was tested under 20A branch circuit in accordance with the National Electrical Code, ANSI/NFPA 70. To reduce the risk of fire, connect only to a circuit provided with 20A maximum branch overcurrent protection. Battery Safety ! CAUTION Do not dispose of batteries in a fire. The batteries may explode. Do not open or mutilate the batteries. Released electrolyte is toxic and is harmful to skin and eyes. Dispose of used batteries according to the instructions.
GLOSSARY OF SYMBOLS Risk of electrical shock ! Indicates caution followed by important instructions AC input AC output i - Requests the user to consult the manual + Indicates the unit contains a valve-regulated lead acid battery PbH2SO4 R Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage WEEE 3 Liebert® GXT4™
Product Description 1.0 PRODUCT DESCRIPTION The Liebert GXT4 is a compact, online uninterruptible power system (UPS) that continuously conditions and regulates its output voltage. The Liebert GXT4 is designed to supply microcomputers and other sensitive equipment with clean sine wave input power. Upon generation, AC power is clean and stable.
Product Description 1.3 Appearance and Components 1.3.1 Front Panel and Controls The Liebert GXT4 rack/tower models in various power ratings have the same general appearance, controls and features (see Figure 1). The various rack/tower and minitower models differ largely in the type of receptacles each has. Figure 1 Liebert GXT4 rack/tower models—front view Ventilation Slots 1.3.
Product Description Figure 3 Rear panel components—Liebert GXT4 120V rack/tower, 1500VA model Input Power Plug and Cable Liebert IntelliSlot Port USB Port Terminal Block RS232 Communication Port Figure 4 Input Circuit Breaker Cooling Fan External Battery Connector General Output Receptacle Strain Relief Attachment Programmable Output Receptacle #2 Programmable Output Receptacle #1 Rear panel components—Liebert GXT4 120V rack/tower, 2000VA model Input Power Plug and Cable Liebert IntelliSlot P
Product Description Figure 5 Rear panel components—Liebert GXT4 120V rack/tower, 3000VA model Liebert IntelliSlot Port Terminal Block Communication Input Power Plug and Cable USB Port RS232 Port General Output Receptacle Input Circuit Breaker Cooling Fan External Battery Connector Programmable Output Receptacle #2 Programmable Output Receptacle #1 Output Output Circuit Breaker Strain Relief Attachment Figure 6 Rear panel components—Liebert GXT4 208V rack/tower, 3000VA model Input Power Plu
Product Description 1.4 Major Components The operating principle of the UPS is illustrated in Figure 7. Figure 7 Operating principle diagram Dynamic Bypass L N/L2* G TVSS EMI/RFI Input Filter Rectifier/ PFC Inverter L EMI/RFI Output N/L2* Filter G Programmable Outlet Group 1 Programmable Outlet Group 2 General Outlet Group DC-DC Converter General Outlet (3000 VA Only) Battery Charger Battery * NOTE: ONLY the GXT4-3000 RT208 model (208V) requires L 2 (L6-20P).
Product Description DC-to-DC Converter The DC-to-DC converter raises the DC voltage from the battery to the optimum operating voltage for the inverter. This allows the inverter to operate continuously at its optimum efficiency and voltage, thus increasing reliability. Battery The Liebert GXT4 uses valve-regulated, nonspillable, lead acid batteries. To maintain battery design life, operate the Liebert GXT4 in an ambient temperature of 32°F to 77°F (0°C to 25°C).
Product Description 1.5.3 Battery Mode The Liebert GXT4 enters Battery Mode when mains power fails or is outside acceptable limits. The battery system supplies power through the DC-to-DC converter to the inverter to generate clean AC power for the connected loads. When the Liebert GXT4 enters Battery Mode, the UPS sounds a half-second beep at 10-second intervals.
Installation 2.0 INSTALLATION 2.1 Unpacking and Inspection Unpack the UPS and conduct the following checks: • Inspect the UPS for shipping damage. If any shipping damage is found, report it to the carrier and your local dealer or your Emerson representative immediately. • Check the accessories included in packaging list. If there is any discrepancy, contact your local dealer or your Emerson representative immediately. 2.
Installation 2.4 Mechanical Installation The Liebert GXT4 may be installed as a tower or in a rack, depending on space and use considerations. The Liebert GXT4 may be used alone, as a single UPS, or with up to four battery cabinets. NOTE When installing the UPS or making input and output connections, comply with all relevant safety codes and standards 2.4.1 Tower Installation To install the Liebert GXT4 as a tower: 1. Take out support bases from the accessories (see Figure 8).
Installation Figure 10 Rotate the operation and display panel Rotate Operation and Display Panel 90 degrees clockwise c. Pull the logo on the front plastic bezel cover gently, rotate it 90 degrees clockwise and snap it back into position. The rotated front plastic bezel cover is shown in Figure 11. d. Replace the front plastic bezel cover on the Liebert GXT4. At this point, the UPS operation and display panel and logo have been rotated 90 degrees clockwise, which provides upright viewing for users. 5.
Installation 2.5 Cable Connection The Liebert GXT4 rear panel has an input cable and plug, output receptacles and output cable(s) (Output cables are on GXT4-3000 models only). Refer to 1.3.2 - Rear Panel Features for details. The battery cables are supplied with the battery cabinet. 2.5.1 Connecting to AC Mains and Loads NOTE Ensure that all the loads are turned Off. Prepare an input power supply that is properly protected by a circuit breaker in accordance with national and local electrical codes.
Installation 2.5.2 Connecting Battery Cables 1. Switch Off the input breaker of the battery cabinet. 2. Take out the battery cable included with the battery cabinet. 3. Connect one end of the battery cable to the external battery connector on the rear panel of the UPS, and connect the other end to any battery port on the rear panel of the battery cabinet. 4. Switch On the battery breaker on the rear of the external battery cabinet. 5.
Operation and Display Panel 3.0 OPERATION AND DISPLAY PANEL This chapter describes the Liebert GXT4 controls, particularly the operation and display panel on the front of the Liebert GXT4. The panel has four control buttons, seven LED indicators and a liquid crystal display (LCD), as shown in Figure 14.
Operation and Display Panel 3.2 Control Buttons The four control buttons on the front of the operation and display panel are: • • • • ESC Up Down Enter Figure 14 shows the buttons’ locations; their descriptions and functions are shown in Table 4. Table 4 3.3 Control buttons Control Buttons Description ESC Button Pressing this button returns to the previous menu or aborts any change in the input data field before confirming.
Operation and Display Panel 3.4 Menu Structure The menu structure of the LCD is shown in Figure 15. Figure 15 Menu structure Audible Alarm Output Startup on Bypass Load Status UPS Battery Enable Auto Restart Time Since Startup Frequency Selection Start Windows System Status Enable Auto Shutdown Input Output Level Selection Configuration Battery Cabinets Turn UPS On/Off Turn UPS On Turn UPS Off BATT Low Battery Time Warning Batt Test Interval Main Menu Control Alarm Control 1.
Operation and Display Panel 3.4.1 Startup Screen When the Liebert GXT4 is starting up, it initiates a self-test and displays the screen shown in Figure 16 for about 10 seconds. Figure 16 Startup screen EMERSON Network Power After about 10 seconds, the LCD shows one of the On screens in Figure 17; the screen shown depends on whether input power is available. Figure 17 Startup screens O/P: 0V HZ 0.0A I/P : 120 V 60HZ 0.
Operation and Display Panel 3.4.2 Default Screen Press any button in the START SUCCESSFUL screen to enter the default interface, shown in Figure 19. Figure 19 Default screen GXT4-UPS 3KVA Values shown will vary according to installation and configuration. O/P: 120V 60HZ 11.7A I /P: 120V 60HZ 13.1A BATT: 100 % 3MINS LOAD: 100% In the default screen, the LCD shows the UPS model, output parameters, input parameters, battery capacity with run time estimate and load percentage.
Operation and Display Panel STATUS Screen In the MAIN MENU screen, select STATUS to enter the Status Screen, displaying OUTPUT, LOAD, INPUT, BATTERY and TIME SINCE STARTUP, as shown in Figure 21. Figure 21 Status screens OUTPUT LOAD VOLTAGE : 120V FREQUENCY : 60HZ CURRENT : 17.6A POWER : 2112 KWH CAP : WATT : VA : INPUT VOLT FREQ CURR POWER 90% 1620W 1800VA : : : : 120V 60 HZ 18.
Operation and Display Panel UPS Screen Select MAIN MENU > CONFIGURATION > UPS to enter the UPS screen. This menu has six screens, as shown in Figure 23. Figure 23 UPS screens AUDIBLE ALARM STARTUP ON BYPASS GUARANTEE SHUTDOWN OFF NO NO ENABLE AUTO RESTART FREQUENCY SELECTION VOLTAGE SELECTION YES AUTO - BYPASS ENABLE 230 Press the Up or Down button to move the cursor to the required item, and press the Enter button to confirm the settings.
Operation and Display Panel ECO Mode Screens Select MAIN MENU > CONFIGURATION > ECO MODE to enter the ECO MODE screens, as shown in Figure 25. Figure 25 ECO Mode screen ECO MODE VOLTAGE TOLERANCE ON 10% FREQUENCY TOLERANCE REQUALIFICATION TIME 3 Hz 5 MINS Press the Up or Down button to move the cursor to the required item, and press the Enter button to confirm the settings. Outlet1 Screen Select MAIN MENU > 2 CONFIGURATION > 4 OUTLET1 to enter the OUTLET1 screen.
Operation and Display Panel Select 1 OUTLET CONTROL and press the Enter button to enter the OUTLET CONTROL screen, as shown in Figure 27. Figure 27 Outlet Control screen OUTLET CONTROL OUTLET CONTROL TURN OFF REBOOT TURN ON Outlet Control is On Outlet Control is Off Press the Up or Down button to move the cursor to the required item, and press the Enter button to confirm the settings. Select 2 Outlet Setting and press the Enter button to enter the OUTLET SETTING screen, as shown in Figure 28.
Operation and Display Panel Outlet2 Screen The Outlet2 screens are the same as the Outlet1 screens. The same settings are available as on the Outlet1 screen. If the Outlet2 group will have the same settings as the Outlet1 group, the Liebert GXT4 offers a programming shortcut, as shown in Figure 29. When configuring the Outlet2 group, the select YES and press the Enter button to apply the Outlet1 settings to the Outlet2 screen.
Operation and Display Panel Select ‘2 COLOR’ and press the Enter button to enter the COLOR screen, as shown in Figure 32. Figure 32 Color screen EMERSON EMERSON EMERSON EMERSON FACTORY DEFAULT screen Select MAIN MENU -> 2 CONFIGURATION -> 7 FACTORY DEFAULT to enter the FACTORY DEFAULT screen, as shown in Figure 33. Figure 33 Factory Default screen RESET ALL SETTINGS TO FACTORY DEFAULT SETTINGS? YES NO Control Screen Select MAIN MENU -> 3 CONTROL to enter the CONTROL screen.
Operation and Display Panel TURN ON & OFF screen Select MAIN MENU -> 3 CONTROL -> 1 TURN ON & OFF to enter the TURN ON & OFF screen. This screen shows one of two displays, TURN ON UPS and TURN OFF UPS, depending on the state of the UPS, as shown in Figure 35. Figure 35 Turn UPS On or Off screen TURN OFF UPS TURN ON UPS BYPASS TURN ON UPS UPS is Off UPS is On ALARM CONTROL screen Select MAIN MENU -> 3 CONTROL -> 2 ALARM CONTROL to enter the ALARM CONTROL screen, as shown in Figure 36.
Operation and Display Panel Log Screen Select MAIN MENU -> 4 LOG to enter the LOG screen. This screen has two submenus, VIEW LOG and CLEAR LOG, as shown in Figure 38. Figure 38 Log screens 254 /255 1 VIEW LOG 2 CLEAR LOG 255 OD 1H 17m AGO UPS switch to Online mode CLEAR LOG Screen Select MAIN MENU > LOG > CLEAR LOG to enter the CLEAR LOG screen, as shown in Figure 39.
Operation and Display Panel Network Select MAIN MENU>NETWORK to enter the NETWORK screen. The NETWORK screen displays the MAC address and the IPv4 IP address. If the Liebert GXT4 is fitted with an optional Liebert IntelliSlot® Web card (Liebert IS-WEBCARD), the screen will display IPv6 IP address settings (IPv6 requires configuration), as shown in Figure 41. Figure 41 Network screens ADDRESS MAC ADDRESS IPV4 ADDRESS IPV6 STATIC 00-02-11-4X-AX 10.163.226 .
Operation and Display Panel 3.4.4 Prompt List A prompt screen is displayed during the operation of the system to alert you to certain conditions and/or to require your confirmation of a command or other operation. See Table 5 for the prompts and meanings. Table 5 3.4.5 System prompts and meanings Prompt Meanings Mains Power Restored The mains power returns and the UPS transfers back to mains (AC) mode.
Operation and Display Panel 3.4.6 Fault List All UPS fault messages are described in Table 7. Table 7 Fault list Fault Description UPS Self-Test Failed The battery is bad or weak or not connected. UPS Overload The UPS is overloaded. Inverter Out Of Order The inverter has failed. Battery Weak/Bad The battery is bad or weak. Output Short Circuit The output connection is short-circuited. DC Bus Overvoltage The DC bus is faulty.
Operation 4.0 OPERATION This section describes checks to be made before starting the UPS, how to start the UPS, manual battery test, manual bypass, shutting down the UPS and disconnecting mains power from the UPS. NOTE The Liebert GXT4’s battery has been fully charged before delivery, but some charge will be lost during storage and shipping. To ensure that the battery has adequate reserve power to protect the connected load, charge the battery for three hours before putting the UPS into service. 4.
Operation 4.5 Shut Down the Liebert GXT4 To shut down the UPS from the LCD: 1. From the Main Menu select CONTROL, press Enter, then select TURN ON & OFF. 2. Press the Enter key. 3. Select TURN UPS OFF, then press Enter. Press either the Up or Down button to move the cursor to confirm the turn off command and press Enter. The UPS will sound an audible alarm; this is normal. 4. Power to the connected equipment is now Off.
Communication 5.0 COMMUNICATION This section describes the four types of communication ports on the rear of the UPS: • • • • Liebert IntelliSlot® port USB port (standard B-type) Terminal Block Communication RS232 port (DB9F) ! CAUTION To maintain safety (SELV) barriers and for electromagnetic compatibility, signal cables should be segregated and run separate from all other power cables. 5.
Communication 5.2.1 Configuration Program The configuration program is on the Liebert GXT4 CD and can be used instead of making configuration setting changes from the LCD panel. The configuration program communicates to a computer running a Microsoft® Windows® operating system via the included USB cable. For most users, the factory default settings are adequate. This section give a brief overview of the features and parameters that are available for modification, as well as the factory default settings.
Communication 5.3 RS-232 Port The RS-232 port uses an Emerson® proprietary protocol that is for use with Liebert MultiLink®. This port enables a more secure connection instead of the USB cable, to the computer or server that has Liebert MultiLink installed. 5.4 Terminal Block Communication The Terminal Block includes eight pins, as shown in Figure 42. Figure 42 Terminal Block Communication pin layout 5.4.
Communication 5.4.2 Battery Mode Shutdown Battery Mode Shutdown permits shutting down the UPS by turning Off the rectifier, inverter and static switch so that there is no power to the load when the UPS is On Battery. The auxiliary power for the UPS will still be active. Battery Mode Shutdown can be performed locally or remotely: • Local Battery Mode shutdown can be performed by shorting Pin3 and Pin4.
Maintenance 6.0 MAINTENANCE This section describes replacing the internal battery pack, precautions, checking the Liebert GXT4’s status and checking UPS functions. ! WARNING The battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed before replacing the battery pack: • Remove rings, watches and other metal objects. • Use tools with insulated handles. • Do not lay tools or other metal objects on the batteries.
Maintenance 6.1.1 Battery Replacement Procedures 1. Remove the front plastic bezel cover from the UPS. 2. Loosen and remove the six screws on the battery door, as shown in Figure 43. 3. Lay the battery door and screws aside for reassembly. Figure 43 Removing the front bezel cover and battery door 4. Gently pull the battery wire out and disconnect the battery plug and battery receptacle, as shown in Figure 44.
Maintenance 6. Unpack the new internal battery pack. Take care not to destroy the packing. Compare the new and old internal battery pack to make sure they are the same type and model. If so, proceed with Step 7; if they are different, stop and contact your local Emerson representative, or Emerson Channel Support. 7. Line up and slide in the new internal battery pack. 8. Reconnect the battery plug and battery receptacle 9. Push the battery wire and internal battery pack back into the UPS. 10.
Troubleshooting 7.0 TROUBLESHOOTING This section indicates various UPS symptoms a user may encounter and provides a troubleshooting guide in the event the UPS develops a problem. Use the following information to determine whether external factors caused the problem and how to remedy the situation. 7.1 UPS Symptoms The following symptoms indicate the Liebert GXT4 is malfunctioning: • The relative indicators illuminate, indicating the UPS has detected a problem.
Troubleshooting 7.1.2 Audible Alarm An audible alarm will sound in conjunction with the visual indicators to indicate a change in UPS operating status. The audible alarm will sound as described in Table 11.
Battery Cabinet 8.0 BATTERY CABINET Optional battery cabinets are available for the Liebert GXT4. The battery connectors and input breaker are on the battery cabinet’s rear panel, as shown in Figure 46. For battery cabinet specifications, refer to Table 15. The Liebert GXT4 may be equipped with a maximum of six extension battery packs. For battery run times, refer to Table 17.
Specifications 9.0 SPECIFICATIONS Table 13 Specifications of GXT4-500RT120 - GXT4-700RT120 and GXT4-1000RT120 models Product Model GXT4-500RT120 (500VA/450W) Parameters GXT4-700RT120 (700VA/630W) GXT4-1000RT120 (1000VA/900W) Dimensions, D × W × H, in. (mm) Unit 16.2 x 16.9 x 3.4 (408 x 430 x 85) Shipping 25.5 x 23.9 x 10.6 (647 x 607 x 270) Weight, lb (kg) Unit 40 (18.2) Shipping 47 (21.
Specifications Table 14 Specifications of GXT4-1500RT120 - GXT4-3000RT120 and GXT4-3000RT208 models Product Model GXT4-1500RT120 (1500VA/1350W) Parameters GXT4-2000RT120 GXT4-3000RT120 (2000VA/1800W) (3000VA/2700W) GXT4-3000RT208 (3000VA/2700W) Dimensions, D × W × H, in. (mm) Unit Shipping 19.7 x 16.9 x 3.4 (497 × 430 × 85) 25.5 x 23.9 x 10.6 (647 x 607 x 270) 23.7 x 16.9 x 3.4 (602 × 430 × 85) 29.4 x 23.4 x 10.6 (747 x 607 x 270) Weight, lb. (kg) Unit Shipping 54.6 (24.8) 69.6 (31.6) 56.1 (25.
Specifications Table 15 Battery cabinet specifications Model Number Parameter GXT4-48VBATT GXT4-72VBATT Used w/UPS Model GXT4-500RT120,GXT4-700RT120 GXT4-1000RT120,GXT4-1500RT120, GXT4-2000RT120 GXT4-3000RT120 GXT4-3000RT208 Unit 19.7 x 16.9 x 3.3 (497 × 430 × 85) 23.7 x 16.9 x 3.3 (602 × 430 × 85) Shipping 24.3 x 22.4 x 10.3 (617 x 570 x 262) 28.2 x 22.4 x 10.3 (717 x 570 x 262) 57.3 (26) 83.
Specifications Table 17 Battery run times Number of External Battery Cabinets Internal Battery Internal Battery + 1 External Battery Cabinet Internal Battery + 2 External Battery Cabinets Internal Battery + 3 External Battery Cabinets 208VAC RT Model 120VAC RT Models Load Percent of Capacity 500VA 700VA 1000VA 1500VA 2000VA 3000VA 3000VA 10% 128 105 90 123 92 82 92 20% 82 61 37 52 38 38 39 30% 41 37 30 34 23 23 23 40% 38 32 23 23 16 16 16 50% 34 27 17 18
Specifications Table 17 Battery run times (continued) Number of External Battery Cabinets Internal Battery + 4 External Battery Cabinets Internal Battery + 5 External Battery Cabinets Internal Battery + 6 External Battery Cabinets 208VAC RT Model 120VAC RT Models Load Percent of Capacity 500VA 700VA 1000VA 1500VA 2000VA 3000VA 3000VA 10% 480 480 480 480 480 466 480 20% 480 480 459 446 424 421 423 30% 480 457 435 341 308 307 307 40% 460 441 339 309 192 192 191
Specifications 9.1 Product Warranty Registration Registration is not required to activate the product warranty on a Liebert UPS. Registration is required to qualify for the Product Protection Promise. To register, visit the Emerson Network Power® Web site to fill out the online form at: www.emersonnetworkpower.com/en-US/Forms/Pages/LiebertProductWarrantyRegistration.aspx • To contact warranty support by e-mail: dpg.warranty@emerson.com 9.
Technical Support / Service Web Site www.liebert.com Monitoring liebert.monitoring@emerson.com 800-222-5877 Outside North America: +00800 1155 4499 Single-Phase UPS & Server Cabinets liebert.upstech@emerson.