Quick Start Guide

Liebert Intellislot
®
485 Card
With Adapter
Quick Start Guide
INSTALL
Locate the adapter mounting location in your Liebert equipment.
Secure the Intellislot 485 Card with Adapter with the supplied screws.
Connect the equipment's communication cable to the TB1 terminal
block or P1 on the card (See equipment user manual for details).
Connect a Modbus (RS-485) cable to the TB2 terminal block.
Connect an input power supply cable to Pins 1 & 2 on the TB3 terminal
block; Pin 1 is at the far left, and Pin 2 is the middle pin.
CONNECT THE CABLE
Locate the blue serial configuration cable (null modem) that shipped
with the card.
Connect the configuration cable to the DB-9 port on the card and to a
COM port on your PC.
CONFIGURE THE CARD
Use terminal emulation software, such as
HyperTerminal
, to open a direct connec-
tion to the card. Use the data at right to
configure the emulation software.
•Press Enter for the Main Menu.
Select the option for 485 Network Set-
tings and press Enter to access the com-
munications settings.
Enter 1 and press Enter.
Select Modbus Server to enable the Modbus application.
At the next screen, enter 3 to access the screen to set the Server ID
(the ID default is 1, but may be any number up to 255).
•Press Esc to return to the Main Menu.
Enter X and press Enter to exit HyperTerminal, save your changes
and reboot the card.
TB3
(P1: +)
(P2: -)
(P3: NC)
P1 is on
left end of
terminal
block.
TB2
(P1: +)
(P2: -);
P1 is at the
right side of
terminal block.
P1
DB-9
Port
TB1 (P1: +; P2: -); P1 is at the
right side of terminal block.
Emulation Software
Configuration
Baud Rate: 9600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None

Summary of content (2 pages)