4. Remove the center screw (4) in the
switch housing cover (5). Insert the
black and white wires from the light kit
fitter (6) thru the hole and thread the
switch housing cover tightly onto the
light kit fitter.
5. Insert the black and white wires through
the lockwasher (7) and hex nut (8)
(supplied). Firmly tighten the hex nut to
secure the light fitter to the cover.
6. Carefully pull down the white and blue
wires from the switch housing (1) and
remove the wire connectors.
7. Connect the white wire from the ceiling
fan to the white wire of the light kit fitter
(6). Connect the blue wire from the
ceiling fan to the black wire of the light
kit fitter. Use listed wire connectors (3)
(supplied) to make connections
(Figures 4 and 5).
Air Comfort Products
DIVISION OF EMERSON ELECTRIC CO.
8100 W. Florissant • St. Louis, MO 63136
10. Proceed to “Installation of Glass
Globes” section.
Installation of Glass Globes
1. Install a 60-watt (maximum) medium
base bulb into each of the three lamp
holder sockets.
2. Back out the three thumb screws in each
of the three lamp holders (Figure 6).
Position the glass globes in the lamp
holders and securely tighten the thumb
screws.
NOTE: It is advisable to periodically
check the tightness of the thumb
screws.
3. Align the four holes in the cage with the
four studs in the lamp holder and secure
the cage in place using the decorative
four nuts. Repeat for the other two lamp
holders.
4. Install the chain and pendant (supplied)
onto the light fitter chain.
Part No. BP7264-5
Form No. F40BP72640005
Printed in China 03/09
To avoid fire hazard, do not exceed
three 60-watt (maximum) medium
base bulbs.
THUMB SCREW
LAMP HOLDER
DECORATIVE
NUT
CAGE
LIGHT BULB (1 PER
SOCKET)
GLASS GLOBE
STUD
Figure 6
WARNING
!
To avoid fire or electrical shock, be
careful not to pinch wires between
the switch housing assembly and
the cover.
WARNING
!
Figure 5
To avoid possible fire or electrical
shock, make certain no bare wire
strands are exposed outside wire
connectors.
WARNING
!
Form No. F40BP72640004 Part No. BP7264-5
U.L. Model No.: LK40
READ AND SAVE THESE INSTRUCTIONS
Model No.
LK40
Series
Net Weight: 4.5 Lbs.
LIMITED WARRANTY
What The Warranty Covers:
All products covered by this Owner’s Manual are warranted against all defects in workmanship and materials. You must be the original purchaser or
user of the product to be covered.
What The Period Of Coverage Is:
All components are covered by this warranty for one year from the date you purchased your light fixture. ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED
TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Light Fixture at no charge to you. WE WILL SHIP THE REPAIRED PRODUCT OR
REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL, REINSTALLATION AND SHIPPING OF THE
PRODUCT TO EMERSON ELECTRIC CO.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE LIGHT FIXTURE TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR
OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of
Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Light
Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
This warranty also does not cover any defects, malfunctions or failures caused by:
Repairs by persons not authorized by Emerson Electric Co.,
Use of parts or accessories not authorized by Emerson Electric Co.,
Mishandling, improper installation, modifications or damage to your light fixture while in your possession, or
Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
The original purchaser or user ceases to own the product, or
The ceiling fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no
employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT
RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not
limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing
other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to
you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
BOARDWALK Light
Fixture Owner's Manual
SUITABLE FOR DAMP LOCATIONS
THREE 60-WATT
MEDIUM BASE BULBS
U
L
®
8. Carefully tuck all wires and splices into
the switch housing (1).
9. Attach the cover/light fitter (5)(6) to the
switch assembly housing (1) using the
two screws (2) that were removed in
Step 3 (Figure 4).
60-WATT (MAXIMUM)
MEDIUM BASE BULB