Ordering Guides

1095ORB-GMCSS / 0614
Outdoor Solution With DC Power
The outdoor site solution includes the NetSure
211 power system
and the NetXtend
Compact 2416 cabinet. The NetXtend
Compact 2416 is a small single sided low-cost outdoor rated
aluminum enclosure with a heat exchanger cooling system.
n NEMA 3R design protects equipment from water and dust,
while maintaining a cool operating environment
n NetSure
rectifiers are designed to operate from -40 °C to
+75 °C, providing 400 W output at 65 °C, suitable for harsh
environmental conditions
n UL and cUL listing
ensures documented
performance
n GR-487-CORE Issue 3
design ensures
system reliability
and durability
Application
The Outdoor Solution With DC Power is ideal for inconspicuous
deployment of Alternative Access Vendor (AAV) applications,
mobile 2G/3G/4G cellular base stations, DAS nodes, mobile back-
haul, remote power solutions, fiber (FTTx) nodes, advanced
metering management (AMM) nodes or hybrid controller
systems (solar, wind, etc.).
Dimensions
16.00"
24.00"
24.00"
Compact Indoor and Outdoor Cell Site Solutions
8.57"
16.67"
Technical Specifications
Electrical
System Voltage
120 VAC single phase (nominal)
Output Voltage -42 VDC to -58 VDC
System Capacity 19" 1 RU up to 8 A
Rectifier Capacity 0.4 kW @ 120 VAC
DC Distribution Wallmount GMT fuse panel with (10) fuses, up to 15 A
Controller SCU+ controller
Physical Characteristics
Framework Type
NetXtend
Compact Enclosure
Available Space
Up to 14 RU, 19" W
Dimensions
(H x W x D)
Enclosure: 24" x 24" x 16"
Battery tray: 22" W x 13" D
Mounting
Wall or H-frame, pole mount (wall-mount kit included)
Weight, Equipped
Enclosure: 64 lb., w/out batteries
Four (4) batteries: 36 lb. total
Access
Front
Environmental
Climate System Heat Exchanger
Operating Temp. -40 °C to +52 °C
Storage Temp. -40 °C to +75 °C
Relative Humidity 100%
EMI/RFI Conforms to FCC rules Part 15, Subpart B, Class B and EN55022
Class B, radiated and conducted
Safety Compliance cULus 60950 Recognized, NEBS Level 3 Compliance
Enclosure: cULus Listed GR-487
*
See rectifier specification for any derating. Operating and storage temperatures for
batteries installed in the battery cabinet are provided by the battery manufacturer.
Ordering Information
Emerson
Number
Description
Emerson
Number
Description
F2013074 Outdoor Solution w/DC Power F2014025 Outdoor Solution w/DC Power
Equipped with the following: Equipped with the following:
1 EA NetXtend
Compact with heat
exchanger,
NXC2416AAV1H05BB3
and slide-out shelf
1 EA NetXtend
Compact with heat
exchanger,
NXC2416AAV1H05BB3
(no slide-out shelf)
1 EA NetSure
211 power system 1 EA NetSure
211 power system
2 EA 500 W rectifiers 2 EA 500 W rectifiers
1 EA 19" rack-mount, slide-out tray 1 EA AC outlet mounting bracket
1 EA AC outlet mounting bracket 2 EA 20 A, 120 VAC outlets
2 EA 20 A, 120 VAC outlets 1 EA Wall-mounting kit
1 EA Wall-mounting kit
Accessories
547681 Battery, EnerSys NP12-12,12 AH bat mod, 4 EA
524855 Battery, GNB Marathon, M12V30NT, 30 AH bat mod, 4 EA
140454 Battery, C&D 12-45, 45 AH bat mod, 4 EA

Summary of content (4 pages)