ExAMPLE: You select EMR and have your heating programmed to 65° at night and 70° at 7 AM. If the building
temperature is 65° the difference between 65° and 70° is 5°. Allowing 5 minutes per degree the thermostat
setpoint will change to 70° at 6:35 AM.
• °F/°C CONVERTIBILITY — The factory default setting is Fahrenheit. Clipping W904 jumper on the circuit board
will alter this feature to Celsius temperature setting.
• LOW BATTERY INDICATOR — If the 2 “AAA” alkaline batteries are low and should be replaced, the display will
be blank except for . When the batteries are low, pressing any button will cause the display
to operate for ten seconds. After ten seconds, the display will be blank except for . After
has been displayed for 4 weeks, the thermostat will raise the temperature 10° above your
setpoint in COOL mode and drop the temperature 10° below your setpoint in HEAT mode. You cannot program
with low batteries, but you can override setpoint temperature.
• TEMPERATURE DISPLAY ADJUSTMENT — Your new thermostat has been accurately set in our factory.
However, if you wish, you may adjust your new thermostat temperature display to match your old thermostat.
This can be accomplished (within a ±3° range) as follows:
1. Press PRGM and RUN buttons at the same time.
2. Press or to adjust the displayed temperature to your desired setting.
3. Press RUN to resume normal program operation.