BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 1 READ AND SAVE THESE INSTRUCTIONS Ceiling Fan/Light Receiver & Reverse Module Owner's Manual For Use With SR600 Remote Control, SR650 Remote Control and SW605 Wall Control Receiver Model Numbers: RC188 & RC212 6-Speed Receiver RC188 Receiver Supplied with Reverse Module for 188 Motor Fans with Small Canopies RC212 Receiver Supplied with Reverse Module for 212 Motor Fans RC188 Receiver & Module For Use Only with Emerson Ceiling Fan Models: CF755,
BP7415 RC188 & RC212 Receiver 10/30/09 ! 11:29 AM Page 2 WARNING Safety Instructions WARNING: To avoid fire, shock, and serious personal injury, follow all instructions carefully. 1. Read your Owner's Manual carefully before installing the Receiver. Retain Owner's Manual for future reference. 2. Before servicing or cleaning the ceiling fan, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 3 SECTION ONE: General Your Emerson Ceiling Fan may be used with a SR600 or SR650 Remote Control, a SW605 Wall Control, and a RC188/RC212 6-speed Receiver. The remote control or wall control is designed to control your ceiling fan speed, airflow direction, and light intensity. NOTE: The RC188 Receiver is to be used with the following Emerson ceiling fan models: CF940, CF935, CF755, CF770, CF695, CF690 & CF670.
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM 1. Slide the five switch levers in the remote control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 2. When power is restored, push and hold the fan OFF button ( ) for 3 to 5 seconds to set the code in the receiver. 3. If airflow is desired in the opposite direction, press the ( ) button on the wall control.
BP7415 RC188 & RC212 Receiver 10/30/09 units such as garage door openers, car alarms or security systems. To remedy this situations, simply change the combination code in your transmitter and receiver. 11:29 AM Page 5 WALL BRACKET Preset Memory Feature Your Emerson receiver is equipped with a preset memory feature. If the AC supply to the receiver is powered through a wall switch, when the switch is turned OFF, the control will remember the light intensity and fan speed.
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM SECTION TWO: Page 6 Installation of Wall Control SINGLE-POLE INSTALLATION Setting Operating Frequency of SW605 Wall Control (Figure 6) HOT SW605 FAN/LIGHT WALL CONTROL BLK HI LIGHT Your wall control has code switches which must be set in one of 32 possible code combinations (Figure 5). The five levers (numbered 1, 2, 3, 4, and 5) on the switches are factory-set in the ON (up) position.
BP7415 RC188 & RC212 Receiver ! 10/30/09 11:29 AM 3-WAY INSTALLATION WARNING (On fan controlled by two different wall controls) (See Figures 8 and 9.) Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control. ! 1. Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan wall control into the outlet box.
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM 3-WAY WIRlNG DIAGRAM: NEW CONSTRUCTION STANDARD WIRING FOR EXISTING 3-WAY CONTROLS WARNING ! HOT LIGHT ® EMERSON OFF ON TRAVELER WIRES SW605 FAN/LIGHT WALL CONTROL LIGHT NEUTRAL RECEIVER LOCATED WITHIN THE CEILING COVER ON BLK LOAD BLACK HOT BLK BLK BLK HI HI LIGHT LIGHT MED MED LOW LOW FAN OFF FAN OFF GROUND EMERSON ® EMERSON® OFF FAN/LIGHT WALL CONTROL OFF ON TRAVELER WIRES ON BLACK TRAVELER WIRE 3-WAY WIRING DIAGRAM:
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM 4. If airflow is desired in the opposite direction, press the ( ) button on the wall control. The fan must be operating at any speed for the reverse button to function. The blades will turn in the opposite direction and reverse the airflow.
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM 5. Connect the 6-pin wiring connector of the module to the ceiling fan motor assembly wiring connector. The connectors are keyed and must be mated correctly before they can be engaged (Figure 14).
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM d. Connect the black supply wire to the black/white receiver wire (AC IN L). e. Cut off the end of the blue and yellow receiver wires and strip back insulation 1/2” from the end of the wires. f. Connect the blue fan wire to the blue receiver wire (BOTTOM LIGHT). g. Connect the yellow fan wire to the yellow receiver wire (UPPER LIGHT). CAUTION: If your ceiling fan does NOT have an uplight, there will be NO yellow fan wire.
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 12 LIMITED WARRANTY What The Warranty Covers: All products covered by this Owner’s Manual are warranted against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.