BP7416 RCK55 Receiver 10/30/09 11:20 AM Page 1 READ AND SAVE THESE INSTRUCTIONS Ceiling Fan/Light Receiver & Reverse Module Owner's Manual For Use With SR600 Remote Control, SR650 Remote Control and SW605 Wall Control Receiver Model Numbers: RCK55 6-Speed Receiver RCK55 Receiver Supplied with Reverse Module for K55 Motor Fans The RCK55 Receiver and Module for Use Only with Emerson Ceiling Fan Models: CF4800, CF4500, CF2400,CF2000, CF3900, CF3600, & CF1. Part No. F40BP74160000 Form No.
BP7416 RCK55 Receiver 10/30/09 11:20 AM ! Page 2 WARNING Safety Instructions WARNING: To avoid fire, shock, and serious personal injury, follow all instructions carefully. 1. Read your Owner's Manual carefully before installing the Receiver. Retain Owner's Manual for future reference. 2. Before servicing or cleaning the ceiling fan, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.
BP7416 RCK55 Receiver 10/30/09 11:20 AM Page 3 General SECTION ONE: Your Emerson Ceiling Fanl may be used with a SR600 or SR650 Remote Control, a SW605 Wall Control, and a RCK55 6speed Receiver. The remote control or wall control is designed to control your ceiling fan speed, airflow direction, and light intensity. NOTE: The RCK55 Receiver and Module for Use Only with Emerson Ceiling Fan Models: CF4800, CF4500, CF2400,CF2000, CF3900, CF3600, & CF1.
BP7416 RCK55 Receiver 10/30/09 11:20 AM 1. Slide the five switch levers in the remote control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 2. When power is restored, push and hold the fan OFF button ( ) for 3 to 5 seconds to set the code in the receiver. 3. If airflow is desired in the opposite direction, press the ( ) button on the wall control. The fan must be operating at any speed for the reverse button to function.
BP7416 RCK55 Receiver 10/30/09 11:20 AM getting interference from other remote units such as garage door openers, car alarms or security systems. To remedy this situations, simply change the combination code in your transmitter and receiver. Page 5 WALL BRACKET Preset Memory Feature Your Emerson receiver is equipped with a preset memory feature. If the AC supply to the receiver is powered through a wall switch, when the switch is turned OFF, the control will remember the light intensity and fan speed.
BP7416 RCK55 Receiver 10/30/09 11:20 AM SECTION TWO: Page 6 Installation of Wall Control SINGLE-POLE INSTALLATION Setting Operating Frequency of SW605 Wall Control (Figure 6) HOT SW605 FAN/LIGHT WALL CONTROL BLK HI LIGHT MED Your wall control has code switches which must be set in one of 32 possible code combinations (Figure 5). The five levers (numbered 1, 2, 3, 4, and 5) on the switches are factory-set in the ON (up) position.
BP7416 RCK55 Receiver ! 10/30/09 11:20 AM 3-WAY INSTALLATION WARNING (On fan controlled by two different wall controls) (See Figures 8 and 9.) Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control. ! 1. Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan wall control into the outlet box.
BP7416 RCK55 Receiver 10/30/09 11:20 AM 3-WAY WIRlNG DIAGRAM: NEW CONSTRUCTION STANDARD WIRING FOR EXISTING 3-WAY CONTROLS WARNING ! HOT LIGHT ® EMERSON OFF ON TRAVELER WIRES SW605 FAN/LIGHT WALL CONTROL LIGHT NEUTRAL RECEIVER LOCATED WITHIN THE CEILING COVER ON BLK LOAD BLACK HOT BLK BLK BLK HI HI LIGHT LIGHT MED MED LOW LOW FAN OFF FAN OFF GROUND EMERSON ® EMERSON® OFF FAN/LIGHT WALL CONTROL OFF ON TRAVELER WIRES ON BLACK TRAVELER WIRE 3-WAY WIRING DIAGRAM: RETROFIT
BP7416 RCK55 Receiver 10/30/09 11:20 AM Page 9 4. If airflow is desired in the opposite direction, press the ( ) button on the wall control. The fan must be operating at any speed for the reverse button to function. The blades will turn in the opposite direction and reverse the airflow.
BP7416 RCK55 Receiver 2 10/30/09 11:20 AM Page 10 SEPARATE BLUE WIRE COMING FROM CEILING FAN AND CAP USING WIRE CONNECTOR 1 CF1 & CF2800 YELLOW WIRE (GRAY ON OLDER MODELS AND ON CF2400) REMOVE WIRE CONNECTOR SECURING THREE BLUE WIRES 3 CF1 & CF2800 - INSTALL WIRE CONNECTOR ON YELLOW WIRE (CF2400 - INSTALL WIRE CONNECTOR ON GRAY WIRE) GRAY CAPACITOR WIRE CUT THE YELLOW WIRE AND CAP USING WIRE CONNECTOR CAPACITOR KNURLED NUT PULL CHAIN PLUG Figure 14 UPLIGHT SWITCH Figure 12 6.
BP7416 RCK55 Receiver 10/30/09 11:20 AM 9. Position the reversing module (supplied) in the switch cup; connect the reversing module connector to the motor connector (Figure 15). The connectors are color-coded and keyed and can be connected in only one manner. 13. For Ceiling Fan Models CF4500 and CF4800 (Newer Models) Only. Locate the two yellow wires terminated by a wire connector. Remove the wire connector and separate the wires (Figure 16).
BP7416 RCK55 Receiver 10/30/09 11:20 AM Page 12 16. Assemble your ceiling fan (including the fan blades), install the hanger bracket, and then hang the fan in accordance with the instructions in the Ceiling Fan Owner’s Manual. Wire the ceiling fan and receiver and complete the installation in accordance with the following Steps 17 through 23. 14. For Ceiling Fan Model CF2400 (Older Models) Only. Cut the orange wire midway between the motor coupling and the grommet in the inside of the housing.
BP7416 RCK55 Receiver 10/30/09 11:20 AM Page 13 e. Cut off the end of the blue and yellow receiver wires and strip back insulation 1/2” from the end of the wires. f. Connect the blue fan wire to the blue receiver wire (BOTTOM LIGHT). g. Connect the yellow fan wire to the yellow receiver wire (UPPER LIGHT). CAUTION: If your ceiling fan does NOT have an uplight, there will be NO yellow fan wire. In this case, cap the yellow receiver wire using a wire connector (supplied).
BP7416 RCK55 Receiver 10/30/09 11:20 AM 20. Insert the connected ends of the wires up through the open side of the hanger bracket and into the outlet box as shown in Figure 20. Trouble Shooting Fan/Light Fails to Operate • Check that the speed switch on the fan is set to HIGH (....) speed. • Check that the light switch is on. • Check that the battery is good (red indicator light should light when any button is pressed). • Check that the receiver is wired properly.
BP7416 RCK55 Receiver 10/30/09 11:20 AM Page 15 LIMITED WARRANTY What The Warranty Covers: All products covered by this Owner’s Manual are warranted against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
BP7416 RCK55 Receiver 10/30/09 11:20 AM Page 16 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP74160000 Printed in China 10/09 Form No.