CENTER LINE OF
GAS COMPRESSION
SYSTEM
6"
# 6 @ 12"
EACH WAY
TOP & BOTTOM
COMPRESSOR UNIT
G.A.
G.A.
EL. TOP OF
GRADE
EXCAVATE TO FROST DEPTH AS REQ'D AND BACKFILL
WITH CLSM OR NON-FROST SUSCEPTIBLE FILL
Figure 2. Concrete Pad with Compressor Unit Dimensions - Front View
Once the site has been excavated and prepared, place four inches of sand down on the bed where the foundation will
rest. The sand must be compacted before placing the forms and rebar. After the sand is compacted, use the Vilter GA
drawing to construct the forms for the foundation. With forms in place, install expansion boards on the inside of the
forms, for example, see Figure 3 - Interior Foundation Isolation. Next, place your rebar in the forms as per the Vilter
foundation drawing. When all rebars are in place the concrete can be poured. The concrete must then be trolled level
and a surface texture etched in place. Leave the concrete to cure for at least 28 days.
CONCRETE
SLAB IN
BUILDING
CHAMFER EDGE
COMPRESSOR UNIT
FOUNDATION
ISOLATION JOINT,
1" MINIMUM
THICKNESS
6”
Figure 3. Interior Foundation Isolation
Foundation