Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Wireless Acoustic Transmitter www.rosemount.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Rosemount 708 Wireless Acoustic Transmitter Rosemount 708 Hardware Revision HART® Device Revision Field Communicator Field Device Revision 1 1 Dev v1, DD v1 NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance, make sure to thoroughly understand the contents before installing, using, or maintaining this product.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Explosions could result in death or serious injury: Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Please review the Product Certifications section for any restrictions associated with a safe installation.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Table of Contents SECTION 1 Overview Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 708 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-4708, Rev AD September 2012 APPENDIX A Specifications and Reference Data APPENDIX B Product Certifications APPENDIX C Recommended Practices Rosemount 708 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Performance Specifications. . . . . . . . . .
Reference Manual 00809-0100-4708, Rev AD September 2012 Section 1 Rosemount 708 Overview Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-2 Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-2 Service Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 OVERVIEW 708 Transmitter Benefits of the Rosemount 708 include: • Improved energy efficiency and environmental compliance with acoustic monitoring of steam traps and pressure relief valves • Gain instant visibility to all of your critical steam traps and PRVs through a non-intrusive, WirelessHART® monitoring system • Know you are backed by Emerson’s proven experience in Smart Wireless field instrumentation and expert technical supp
Reference Manual 00809-0100-4708, Rev AD September 2012 Wireless Considerations Rosemount 708 Power Up Sequence The Smart Wireless Gateway (Gateway) should be installed and functioning properly before any wireless devices are powered. Install the power module, SmartPower Solutions, model number 701PGN green power module, into the 708 to power the device. This results in a simpler and faster network installation.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Field Communicator Connections The Power Module needs to be installed in the device for the Field Communicator to interface with the 708. This transmitter uses the Green Power Module; please order model number 701PGNKF. Field communication with this device requires a HART-based Field Communicator using the correct 708 DD. Field communicator connections are located on the power module.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Heat from the process is transferred to the transmitter housing. If the process temperature is high, the ambient temperature will need to be lower to account for heat transferred to the transmitter housing. See Table 1-1 for process temperature derating. Table 1-1.
Reference Manual Rosemount 708 PRODUCT RECYCLING/DISPOSAL 1-6 00809-0100-4708, Rev AD September 2012 Recycling of equipment and packaging should be taken into consideration. The product and packaging should be disposed of in accordance with local and national legislation.
Reference Manual 00809-0100-4708, Rev AD September 2012 Section 2 Rosemount 708 Configuration Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1 Device Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1 Device Network Configuration . . . . . . . . . . . . . . . . . . . . . page 2-2 Remove Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-3 HART Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 AMS® Wireless Configurator AMS Wireless Configurator is capable of connecting to devices directly, using a HART modem, or remotely using the Gateway. To configure the Rosemount 708, double click (or right click and select Configure/Setup) on the device icon that will appear below either the HART modem or Gateway connection tree.
Reference Manual 00809-0100-4708, Rev AD September 2012 Fast Key Sequence Table 2-1. 708 Fast Key Sequence REMOVE POWER MODULE Rosemount 708 Table 2-1 lists the fast key sequence for common transmitter functions.
Reference Manual Rosemount 708 HART MENU TREE Figure 2-2.
Reference Manual 00809-0100-4708, Rev AD September 2012 Section 3 Rosemount 708 Mounting Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1 SAFETY MESSAGES Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations.
Reference Manual Rosemount 708 00809-0100-4708, Rev AD September 2012 Figure 3-1. Transmitter Alignment Figure 3-2. Transmitter Alignment Top View Figure 3-3. Power Module Installation NOTE: Wireless devices should be powered up in order of proximity from the Gateway, beginning with the closest device to the Gateway. This will result in faster network formation.
Reference Manual 00809-0100-4708, Rev AD September 2012 Mounting Considerations Rosemount 708 1. Mounting bands should be inspected periodically and retightened if necessary. Some loosening may occur after initial installation due to thermal expansion/contraction. 2. The waveguide must be in direct contact with the pipe. 3. Insulate process piping to minimize ambient temperature effects (see Figure 3-4). Insulation thickness over the top of the waveguide foot should not exceed 2.54 cm (1-in). 4.
Reference Manual Rosemount 708 3-4 00809-0100-4708, Rev AD September 2012
Reference Manual 00809-0100-4708, Rev AD September 2012 Section 4 Rosemount 708 Commissioning Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-1 Verify Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-1 SAFETY MESSAGES Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Field Communicator For HART Wireless transmitter communication, a 708 DD is required. To obtain the latest DD, visit the Emerson Process Management Easy Upgrade site at: http://www2.emersonprocess.com/en-US/documentation/deviceinstallkits. The communication status may be verified in the wireless device using the following Fast Key sequence.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 NOTE SteamLogic software is provided for viewing steam trap status. Refer to the manual on the CD for more information. Troubleshooting If the device is not joined to the network after power up, verify the correct configuration of the Network ID and Join Key, and that Active Advertising has been enabled on the Gateway. The Network ID and Join Key in the device must match the Network ID and Join Key of the Gateway.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Field Communicator Use NOTE In order to communicate with a Field Communicator, power the 708 by connecting the Power Module. For more information on the Power Module, refer to the Power Module product data sheet (Document No 00813-0100-4701). Table 4-1 includes Fast Key sequences frequently used to interrogate and configure the device. Table 4-1. 708 Fast Key Sequence Figure 4-4.
Reference Manual 00809-0100-4708, Rev AD September 2012 Section 5 Rosemount 708 Operation and Maintenance Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-1 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-1 Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-2 Power Module Replacement . . . . . . . . . . . . . . . . . . . . . . .
Reference Manual Rosemount 708 ALERTS Figure 5-1. AMS Device Manager Overview Screen, Normal Conditions Figure 5-2. AMS Device Manager Overview Screen, Alert Conditions 5-2 00809-0100-4708, Rev AD September 2012 The Rosemount 708 can be configured to report alerts based on the acoustic and temperature level measured. The Rosemount 708 also reports diagnostic alerts when there is a device malfunction. For information on these alerts, refer to Section 6: Troubleshooting.
Reference Manual 00809-0100-4708, Rev AD September 2012 Device Alert Configuration Rosemount 708 Alert Levels The Rosemount 708 provides 4 user configurable alerts. Acoustic High - Triggers when acoustic level exceeds a user configured threshold. Acoustic Low - Triggers when acoustic level falls below a user configured threshold. Temperature High - Triggers when temperature level exceeds a user configured threshold. Temperature Low - Triggers when temperature level falls below a user configured threshold.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Figure 5-4. Install and Learn Alert Setup screen Alert Setup - Guided User Alert Setup Guided user alert setup cycles through on-screen prompts to set the alert levels. At each screen, the current level will be shown along with a box to enter the desired alert level as seen in Figure 5-5. To use the guided alert setup, navigate to the configuration menu under guided setup and click on alert setup. Click on “Guided User Alert Setup.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Figure 5-6. Manual Alert Setup screen If a device is installed and shows an unexpected alert, verify the installation conditions. POWER MODULE REPLACEMENT Expected power module life is ten years at reference conditions.(1) When the power module needs to be replaced, remove the power module cover and the power module (SmartPower Solutions™, model number 701PGN green power module) then replace the power module and the cover.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Shipping Considerations The unit was shipped to you without the power module installed. Please remove the power module prior to shipping. Each power module contains one “D” size primary lithium battery. Primary lithium batteries are regulated in transportation by the U.S.
Reference Manual 00809-0100-4708, Rev AD September 2012 Section 6 Rosemount 708 Troubleshooting Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6-1 Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6-1 OVERVIEW Table 6-1 provides summarized maintenance and troubleshooting suggestions for the most common operating problems.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Table 6-1.
Reference Manual 00809-0100-4708, Rev AD September 2012 Appendix A Rosemount 708 Specifications and Reference Data Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1 Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-3 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-4 SPECIFICATIONS Functional Specifications Output IEC 62591 (WirelessHART) 2.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Weight 708 with power module -0.595 kg (1.31 lb) 708 without power module - 0.445 kg (0.98 lb) Enclosure ratings NEMA 4X and IP66/67 Performance Specifications Vibration Effect Tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10-60 Hz 0.21 mm displacement peak amplitude/60-2000 Hz 3g).
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 DIMENSIONAL DRAWINGS Rosemount 708 Direct Mount Dimensions are in inches (millimeters) A-3
Reference Manual Rosemount 708 00809-0100-4708, Rev AD September 2012 ORDERING INFORMATION Table A-1. Rosemount 708 Acoustic Transmitter Ordering Information ★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time.
Reference Manual 00809-0100-4708, Rev AD September 2012 Appendix B Rosemount 708 Product Certifications Approved Manufacturing Locations . . . . . . . . . . . . . . . . . page B-1 Telecommunication Compliance . . . . . . . . . . . . . . . . . . . . page B-1 FCC and IC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-1 European Union Directive Information . . . . . . . . . . . . . . . page B-1 Ordinary Location Certification for FM . . . . . . . . . . . . . . .
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 Hazardous Locations Certificates North American Certifications Factory Mutual (FM) Approvals I5 Intrinsically Safe Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D Zone Marking: Class I, Zone 0, AEx ia llC Temperature Codes T4 (Tamb = -40 to 70 °C) Ambient temperature limits: -40 to 70 °C For use with SmartPower Solutions, model number 701PGN green power module only.
Reference Manual 00809-0100-4708, Rev AD September 2012 Rosemount 708 IECEx System Certifications I7 IECEx Intrinsic Safety Certificate No.: IECExBAS 11.0091X Ex ia IIC Ga (Ta = -40 °C Tamb 70 °C) IP66/67 For use with SmartPower Solutions, model number 701PGN green power module only. 1180 Special Conditions for Safe Use (X): 1. The engineered polymer enclosure of the Rosemount 708 may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth.
Reference Manual Rosemount 708 00809-0100-4708, Rev AD September 2012 c Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary Figure B-1.
Reference Manual 00809-0100-4708, Rev AD September 2012 Appendix C Rosemount 708 Recommended Practices Effective Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page C-1 All recommended practices should be followed to ensure highest data reliability. Deviation from those best practices may require device repeaters in the network to maintain 99% data reliability. The following are guidelines to achieve the best possible Smart Wireless Network. EFFECTIVE RANGE 1.
Reference Manual Rosemount 708 C-2 00809-0100-4708, Rev AD September 2012
Reference Manual 00809-0100-4708, Rev AC September 2012 The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. HART is a registered trademark of the HART Communication Foundation. Lexan and Noryl are registered trademark of General Electric. All other marks are the property of their respective owners.