CODE POSSIBLE CAUSE POSSIBLE SOLUTION
13 Loose belt Check belt tension, see Adjusting Belt Tension under
Maintenance.
14 Pump or motor mounting nuts are loose Torque pump mounting nuts to 6– 8 ft.-lbs. (8.1–10.8 Nm).
Torque motor mounting bolts to 100– 120 in.-lbs.
(11.3– 13.6 Nm).
WARNING: Risk of bursting. Excessive
vibration could weaken the air tank and cause it to rupture
or explode. Mounting screws must be kept tightened.
15
Motor overload protection switch has tripped See Motor Overload under Features.
16
Loose pulley Tighten pulley set screw, torque to 145–165 in.-lbs.
(16.4– 19.6 Nm).
17
Loose flywheel Tighten flywheel screw, torque to 15–18 ft.-lbs.
(20.3– 24.4 Nm).
18
Carbon build-up in pump Contact an
E
MGLO factory service center or an
E
MGLO
authorized service center.
19
Belt to tight Check belt tension, see Adjusting Belt Tension under
Maintenance.
20
Pulley misalignment See Motor Pulley/Flywheel Alignment under
Maintenance.
21
Extension cord is wrong length or gauge Check for proper gauge wire and cord length. See
Extension Cords under Installation.
22
Loose electrical connections
Contact an
E
MGLO factory service center or an
E
MGLO
authorized service center.
23
Pump oil is low Add E
M
GLO Synthetic Blue compressor oil to pump. See
Compressor Pump Oil
under Maintenance.