Instruction manual
23
English
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
24
Regulator is not adjusted correctly for accessory being
used
It is normal for some pressure drop to occur when an acces-
sory is used, adjust the regulator as instructed in Regulator
under Features if pressure drop is excessive.
NOTE:
Adjust the regulated pressure under flow conditions
while accessory is being used.
25
Damaged regulator Replace.
26
Detergent type oil being used in pump Drain oil and refill pump with E
M
GLO Synthetic Blue
compressor oil.
27
Extremely light duty cycles Run unit for longer duty cycles. It is recommended that a
50%-75% average duty cycle be maintained; that is, the air
compressor pump should not run more than 30-45 minutes
in any given hour.
28
Piston rings damaged or worn Contact an
E
MGLO factory service center or an
E
MGLO
authorized service center.
29
Cylinder or piston damaged or worn Contact an
E
MGLO factory service center or an
E
MGLO
authorized service center.
30
Compressor cylinder finish worn Contact an EMGLO factory service center or an
E
MGLO
authorized service center.
31
Water in pump oil Drain oil and refill pump with E
M
GLO Synthetic Blue
compressor oil.
32
Manual lock unloader lever in open position Rotate manual lock unloader lever to the closed perpendicular
position.
33
Regulator open Rotate the regulator knob counterclockwise to its built-in stop
and push knob in to lock in place.
34
Possible defective motor or starting capacitor
Contact an
E
MGLO factory service center or an
E
MGLO
authorized service center.