Emininence Selection Guide

SELECTION
GUIDE
The Genuine Eminence loudspeaker range comprises five product groups. A wide range of detail improvements have led to enhanced
performance across the entire range with a key benefit being increased power handling in the majority of transducers. To design enclosures
using Eminence transducers, Eminence Designer software is an invaluable aid for calculating and modeling the performance. Take care not to
be influenced only by power statistics — much can be learned from a considered review of a transducer’s Thiele Small parameters, this table
and the Sensitivity table on our website. To replace a loudspeaker in an existing enclosure, you will need to establish its volume in liters or
cubic feet. Again, Eminence Designer can help you, but as a rough guide this table includes a suggested enclosure volume for each
Eminence loudspeaker. Enclosure design is a complex subject however and different enclosure sizes and proportions will affect the sound
characteristics of a loudspeaker. To “Hot Rod” combos, experimentation is all part of the fun!
PROFESSIONAL SERIES
Subwoofer
Up to 150Hz
Woofer
50Hz—2kHz
Mid-Bass
Woofer
200Hz—4kHz
Midrange
600Hz—5kHz
Recommended
Enclosure Volume
(1 cu.ft = 28 liters approx.)
Power
Rating
Magnum® 18LF
iiiii iiii
---- ----
Vented 4—10 cu.ft. 800Wrms
Magnum® 18HO
----
iiiii
---- ----
Vented 4—8 cu.ft. 650Wrms
Magnum
®
15LF
iiiii iiii
---- ----
Vented 3—6 cu.ft. 700Wrms
Magnum
®
15HO
----
iiiii
---- ----
Vented 2—4 cu.ft. 650Wrms
Kilomax
18
iiiii iii
---- ----
Vented 7.5—12.5 cu.ft.
1250Wrms
Kilomax
15
iiiii iii
---- ----
Vented 3.25—5.3 cu.ft.
1250Wrms
Omega Pro 18
iiii iiiii
---- ----
Vented 5 —6 cu.ft.
800Wrms
Omega Pro 15
iiii iiiii
---- ----
Vented 3.4—5.6 cu.ft.
800Wrms
Omega Pro 12
----
iiiii
---- ----
Vented 1.2—2.0 cu.ft.
700Wrms
Sigma Pro 18
iiiii iiiii
---- ----
Vented 3.75—6.25 cu.ft.
650Wrms
Kappa Pro 15LF
iiiii iiii
---- ----
Vented 2.9—4.9 cu.ft. 600Wrms
Kappa Pro 15 ----
iiiii iiii
----
Vented 3.75—6.25 cu.ft. 500Wrms
Kappa Pro 12
iiii iiiii iiii
----
Vented 0.6—0.8 cu.ft. 500Wrms
Kappa Pro 10 ----
iiiii iiii iiii
Vented 0.2—0.3 cu.ft. 500Wrms
Delta Pro 15 ----
iiiii iiii iiii
Vented 2.25—3.75 cu.ft. 400Wrms
Delta Pro 12 ----
iiiii iiiii iiii
Vented 1.8—2.92 cu.ft. 400Wrms
AMERICAN ORIGINALS 0 0 0 0 0 0
Kappa 18
iiiii iiii
---- ----
Vented 6—10 cu.ft. 500Wrms
Kappa 15LF
iiiii iiii
---- ----
Vented 2.9—4.9 cu.ft. 600Wrms
Kappa 15
iiii iiiii
---- ----
Vented 2.25—3.75 cu.ft. 450Wrms
Kappa 12 ---- ----
iiiii iiii
Vented 1—2 cu.ft. 450Wrms
Delta 15LF
iiiii iiii
---- ----
Vented 3.25—5.3 cu.ft. 500Wrms
Delta 15 ----
iiiii iiii
----
Vented 3.75—6.25 cu.ft. 400Wrms
Delta 12LF
iiiii iiii
---- ----
Vented 3—5 cu.ft. 500Wrms
Delta 12 ----
iii iiiii iiii
Vented 2.25—3.75 cu.ft. 400Wrms
Delta 10 ---- ----
iiiii
----
Vented 0.5—0.84 cu.ft. 350Wrms
Gamma 15 ----
iiii iiiii
----
Vented 2.9—4.9 cu.ft. 300Wrms

Summary of content (2 pages)